9-60
HF61 0070O
Modello - Model EWM0XXM
Matricola - Serial number HFXXXXXXXXXX
Codice ID - Code ID
Data di produzione - Date of production 22/08/17
Categoria PED/ 2014/68/EU Category II
Procedura di valutazione conformità - Conformity module D
Max pressione ammissibile PS - Max allowable pressure PS[bar-r] 41,5
"Max pressione esercizio lato bassa pressione PS
Max allowable pressure low pressure side PS [bar-r]"
41,5
Max/Min temp. di stoccaggio - Max-Min storage temperature [°C] +42 / -20
Max/Min.temp.amb. di funzionamento-Max/Min amb.working
temp.[°C] +42 / -20
Potenza frigorifera* - Cooling Capacity* [ kW ]
EER*
Potenza termica* - Heating Capacity* [ kW ]
COP*
Refrigerante - Refrigerant [Ashrae 15/1992] / GWP R410A/2088
Carica refrigerante - Refrigerant charge [kg] C1 C2 C3 C4
(1*) - - -
Refrigerante aggiunto - Refrigerant added [kg] C1 C2 C3 C4
(2*) - - -
Carica totale - Total Charge [kg] (2*)
"Tonnellate di CO2 equivalenti
Tonnes of CO2 equivalent"
Taratura press. lato ALTA - HIGH pressure Switch Set [bar-r] 41,5
Taratura press. lato BASSA - LOW pressure Switch Set [bar-r] -
"Taratura valvola sicurezza refrigerante
Safety valve refrigerant Set [bar-r]"
-
"Massima pressione esercizio circuito acqua
Max working pressure water circuit [bar-r]"
5
"Taratura valvola sicurezza acqua
Safety valve water side Set [bar-r]"
-
Alimentazione Elettrica- Power supply 230V/1ph/50Hz
Potenza massima assorbita - Max. absorbed power [kW] 5
Corrente massima - Full load ampere FLA [A] 22
Corrente di spunto - Starting Current LRA [A] /
Schema elettrico - Wiring diagram HF620Axxxx
Schema frigorifero - Refrigeration diagram HF630Axxxx
Peso a vuoto - Empty weight [kg] 260
"* EN14511-2
Contiene gas uorurati ad eetto serra disciplinati dal protocollo di Kyoto
Contains uorinated greenhouse gases governed by the Kyoto protocol
Ermeticamente sigillato/Hermetically sealed"
- MULTIPURPOSE SPLIT UNIT: AIR-WATER HEAT PUMP
Installation, use and maintenance manual
G
- Before performing any work on the unit, each operator must be perfectly aware of how the
unit and its controls work and must have read and understood all the technical information
in this manual.
- It is forbidden to use the unit in conditions or for purposes other than those stipulated in this manual and The
MANUFACTURER cannot be liable for faults, issues or accidents due to non-compliance with this prohibition.
- Do not repair the high pressure pipes with welding.
- It is prohibited to tamper with, alter or modify, even partially, the systems or equipment referred to in the
instructions manual, particularly the guards provided and symbols regarding personal safety.
- It is also prohibited to operate in any way other than that stipulated or disregard required safety operations.
- Safety guidelines together with general information provided in this manual are particularly important.
ATTENTION
Each unit is characterised by an identication plate, which
is found on the frame. This states all data necessary for
installation, maintenance and traceability of the machine.
Make note of the model, serial number, denitive refrigerant
load and reference layouts of the machine at the end of
this manual in a way that they can be easily found in the
case of deterioration of the data plate and maintenance
interventions.
(1*) The refrigerant load indicated is that already present inside the unit and pre-
loaded in the factory.
(2*) The denitive refrigerant load must be written after installation, by the
technician that performed the job.
1.5 IDENTIFICATION OF THE UNIT
J
EWM