BDAMON02-MODEM USERS MANUAL
BDAMON02-MODEM Manual – V3.D1
© 2019 EMR Corporation
Data String
Changing the “E” Data String line to “Enabled” will send a comma delimited string in the
following format out the Com Port.
Time: Date, Door, Door Alarm, DC Voltage, DC Alarm, AC, AC Alarm, Port#1 Current, Port#1 Alarm,
Port#2 Current, Port#2 Alarm, Port#3 Current, Port#3 Alarm, Port#4 Current, Port#4 Alarm
For Example:
14:42:9/28/2010, 0, 0, 13.80, 0, 0, 0, 0.25, 0, 1.20, 0, 0.27, 0, 0.00,1
Translates to:
14:42:9,9/28/2010, Door Closed, no alarm, 13.80 VDC, no alarm, AC on, no alarm, 0.25
Amps on Amp #1, no alarm, 1.20 Amps on Amp #2, no alarm, 0.27 Amps on Amp #3, no
alarm, 0.00 Amps on Amp #4, alarm on
Password Menu
Press “C” from the “Setup Menu” to display the “Password Setup” menu (Fig. 9). This menu
displays the following option:
Fig. 9
Press “A” to change the password.
************************************************
EMR Corp. BDAMON2MODEM V1.021
************************************************
Password
Select The Following
A>> Password = 123456
X>> Exit
>