Emerson Location Awareness safety messages
Read this Quick Start Guide before working with the product. For personal and system safety and for
optimal product performance, understand the contents completely before installing, using, or
maintaining this product.
Emerson has two toll-free assistance numbers and one international number.
NOTICE
Customer Central
1 800 999 9307 (7:00 a.m. to 7:00 p.m. CST)
National Response Center (equipment service needs)
1 800 654 7768 (24 hours a day)
International
1 952 906 8888
Nuclear qualification
The products described in this document are NOT designed for nuclear-qualified applications. Using
non-nuclear qualified products in applications that require nuclear-qualified hardware or products may
cause inaccurate readings. For information on Rosemount™ nuclear-qualified products, contact an
Emerson Sales Representative.
Wireless Gateway
The Location Anchor and all other wireless devices should be installed only after the Wireless Gateway
has been installed and is functioning properly. Wireless devices should also be powered up in order of
proximity from the Wireless Gateway, beginning with the closest. This will result in a simpler and faster
network configuration. Use caution when making changes to the TCP/IP network settings. If they are
lost or entered incorrectly, the Gateway will require a factory reset. Contact your network
administrator for information on the proper TCP/IP network settings.
Hazardous substance
Individuals handling products exposed to hazardous substances can avoid injury if they are informed of
and understand the hazard. If the returned product was exposed to a hazardous substance as defined
by OSHA, a copy of the Material Safety Data Sheet (MSDS) for each hazardous substance identified
must accompany the returned goods.
Shipping considerations
The Location Anchor unit was shipped with the battery installed. Each Location Anchor contains one
“D” size primary lithium battery. Primary lithium batteries are regulated in transportation by the U. S.
Department of Transportation and are also covered by the International Air Transport Association
(IATA), International Civil Aviation Organization (CAO), and European Ground Transportation of
Dangerous Goods (ARD). It is the shipper’s responsibility to ensure compliance with these or any other
local requirements. Consult current regulations and requirements before shipping. The polymer
enclosure has surface resistivity greater than one giga-ohm. Take care during transportation to and
from the configuration point to prevent a potential electrostatic charging hazard.
Battery considerations
Battery hazards remain when cells are discharged. Electrostatic discharge can damage electronics.
Batteries should be stored in a clean dry area. For maximum battery life, storage temperature should
not exceed 30 °C (86 °F). The Location Anchor battery shall only be replaced in a non-hazardous area.
The Personnel Tag battery is rechargeable and shall only be charged in a non-hazardous area using a Qi
certified charger.
Quick Start Guide February 2020
2 Emerson.com

NOTICE
Installation considerations
Only qualified personnel should perform the installation. Verify the operating atmosphere of the
transmitter is consistent with applicable hazardous area certifications. Reference the Product
Certifications section of this manual for information regarding hazardous certification. This Location
Anchor must be installed to ensure a minimum antenna separation distance of 20 cm (8 in.) from all
persons.
WARNING
Failure to follow these installation guidelines could result in death or serious injury.
Ensure only qualified personnel perform installation or service.
Explosions could result in death or serious injury.
Before connecting a handheld communicator in an explosive atmosphere, ensure the instruments are
installed in accordance with intrinsically safe or non-incendive field wiring practices.
Verify that the operating atmosphere of the transmitter is consistent with the appropriate hazardous
locations certifications.
Electrical shock could cause death or serious injury.
This Location Anchor complies with Part 15 of the FCC Rules. Operation is subject to the following
conditions: This Location Anchor may not cause harmful interference. This Location Anchor must
accept any interference received, including interference that may cause undesired operation.
This Location Anchor must be installed to ensure a minimum antenna separation distance of 20 cm
from all persons.
Physical access
Unauthorized personnel may potentially cause significant damage to an/or misconfiguration of end
users' equipment. This could be intentional or unintentional and needs to be protected against.
Physical security is an important part of any security program and fundamental to protecting your
system. Restrict physical access by unauthorized personnel to protect end user's assets. This is true for
all systems used within the facility.
Contents
Overview......................................................................................................................................5
Installation Plantweb Insight and Plantweb Insight Location application...................................... 7
Location Anchor configuration..................................................................................................... 8
Installation Location Anchor.......................................................................................................11
Location Anchor commissioning................................................................................................ 14
Operation and maintenance.......................................................................................................17
Personnel Tag configuration.......................................................................................................19
Personnel Tag mounting considerations.................................................................................... 21
Personnel Tag operation and maintenance................................................................................ 22
February 2020 Quick Start Guide
Quick Start Guide 3

Product certifications................................................................................................................. 24
Declaration of Conformity..........................................................................................................29
Quick Start Guide February 2020
4 Emerson.com

1 Overview
1.1 Location Awareness solution components
Location Anchor
Location Personnel Tag
February 2020 Quick Start Guide
Quick Start Guide 5

Plantweb™ Insight Location application
1.2 Product recycling/disposal
Recycling of equipment and packaging should be taken into consideration.
The product and packaging should be disposed of in accordance with local
and national legislation.
Quick Start Guide February 2020
6 Emerson.com

2 Installation Plantweb Insight and Plantweb
Insight Location application
2.1 Install Plantweb Insight and Plantweb Insight Location
application
Follow instructions in the Plantweb Insight Quick Start Guide.
February 2020 Quick Start Guide
Quick Start Guide 7

3 Location Anchor configuration
3.1 Safety messages
WARNING
Failure to follow these installation guidelines could result in death or
serious injury.
Ensure only qualified personnel perform the installation.
Explosions could result in death or serious injury.
Before connecting a handheld communicator in an explosive atmosphere,
ensure the instruments are installed in accordance with intrinsically safe or
non-incendive field wiring practices.
Verify that the operating atmosphere of the transmitter is consistent with
the appropriate hazardous locations certifications.
Electrical shock could cause death or serious injury.
Use extreme caution when making contact with the leads and terminals.
This Location Anchor complies with Part 15 of the FCC Rules. Operation is
subject to the following conditions: This Location Anchor may not cause
harmful interference. This Location Anchor must accept any interference
received, including interference that may cause undesired operation.
This Location Anchor must be installed to ensure a minimum antenna
separation distance of 20 cm from all persons.
3.2 Location Anchor configuration
Remove the Location Anchor electronics cover and connect to the HART®
Communication terminals for configuration.
The Emerson Location Anchor will receive HART Communication from any
HART handheld Field Communicator or AMS Device Manager.
AMS Device Manager
AMS Device Manager can connect to devices directly, using a HART modem,
or remotely using the Gateway. To configure the Emerson Location Anchor,
double click (or right click and select Configure/Setup) on the device icon
that will appear below either the HART modem or Gateway connection tree.
Quick Start Guide February 2020
8 Emerson.com

3.3 Device network configuration
To communicate with the Gateway (and ultimately the host system), the
Location Anchor must be configured to communicate with the wireless
network. Using a Field Communicator or AMS Device Manager, enter the
network ID and join key so they match the network ID and join key of the
Gateway and other devices in the network. If they do not match, the
Location Anchor will not communicate with the network. The network ID
and join key may be obtained from the Gateway on the Systems
Settings>Network>Network Settings page on the web server, shown in Figure
3-1.
Figure 3-1: Gateway Network Settings
AMS Device Manager
Right click on the Location Anchor and select Configure. When the menu
opens, select Join Device to Network and follow the method to enter the
network ID and join key. See Table 3-1 for menu items.
February 2020 Quick Start Guide
Quick Start Guide 9

Table 3-1: Device Configuration
Function Menu items
Join device to network Network ID, Set Join Key
Device information Tag, Long Tag, Descriptor, Message,
Date
Guided setup Basic Setup, Join Device to Network,
Configure Update Rates
Manual setup Wireless, Location Network, HART,
Security, Device Information, Power
Wireless Network ID, Join Device to Network,
Broadcast Information
3.4 Power down
After the Location Anchor has been configured, turn off power to the
electronics by moving the power switch to off and reinstall the cover. Power
should only be turned back on when the anchor is ready for commissioning.
Quick Start Guide February 2020
10 Emerson.com