BA-en-2075-2111_ES47 7
2.3 Work and operational safety
Warning!
Carefully observe the following notes and the complete chapter 2 "Safety”,
page 6!
•Before carrying out repairs, cleaning or maintenance work involving the
power supplies and the discharging bars, switch off the power supply
and disconnect the mains power supply (see chapter 5 "Maintenance”,
page 13, chapter 6 "Trouble-shooting”, page 14).
•Before carrying out any work involving the units, the machine which has
the units fitted must not be in operation (see chapter 5 "Maintenance”,
page 13, chapter 5 "Maintenance”, page 13).
• Any work involving the units must be carried out by qualified electricians
(see chapter 5 "Maintenance”, page 13, chapter 6 "Trouble-shooting”,
page 14).
• Before starting the unit make sure that the appliance is permanently
grounded via the ground connection (5, Fig. 1). The ground cable
should have a minimum cross section of 1.5 mm2(see chapter 3.2
"Ground connection”, page 9).
• Disconnect and/or connect the bars and the cables only when the
power supply is swiched off (see chapter 3.4 "Connecting the high vol-
Wage cable”, page 10).
• Terminals at the housing that are not used must be closed with blanking
plugs (see chapter 3.4 "Connecting the high voltage cable”, page 10).
• Check the units, the electrical wiring and the high voltage cables at
regular intervals and before the start-up for any damage. Any damaged
components must be repaired professionally or replaced before con-
tinuing to operate the units.
• If the housing cover is removed, contact protection is no longer effec-
tive. Always disconnect the power before opening the power supply
units.
•The protection class IP54 only applies if the housing cover is closed
and the cable connections are shrouded.
• Both the lengths of the high voltage cable and of the active bars are li-
Pited, observe maximum lengths
• Please note the maximum total lengths of the bars and the high voltage
cables in chapter 3.5. (see chapter 3.6 "Connecting the supply voltage”,
page 11).
• Keep the bars clean at all times. Dirt results in malfunctions and in pre-
mature wear of the units.
• Before starting up the power supply the user must make sure that the
power supply and the bars have been installed and assembled cor-
rectly. The supply voltage can then be switched on (see chapter 4.1
"Startup”, page 12).