4
1. PRELIMINARY INSTRUCTIONS (Setting Up of Accessories)
Turn to the pictorial diagram in Fig. 1 on Page 1.
Place the following accessories incorrect positions respectively.
(a) Ice Tray with divisions (item 1) in the Ice Making Compartment
(b) Defrost (Drip) Tray (item 3) under the Evaporator.
(c) Storage Shelves (item 4,9)
2. CONTROLS
The cold controls for gas and electric operation are inside the food storage compartment on the right side in the rear.
The “on-off” switches, gas on-off, igniter, and the safety valve is located on the back of the unit outside toward the
base.
3. STARTING-Up
3-1 Gas Operation
To start up the refrigeration using L.P. Gas (Bottled Gas):
1) Be sure the refrigerator is level. A spirit level is supplied with the refrigerator. Place this level in the ice
making compartment to check the level of the refrigerator front to back and side to side.
2) Turn on the LP. Gas supply of the bottle.
3) Open the service access door.
4) Set the Elec. DC-AC-OFF Slide Switch (14) to “ELEC OFF” position.
5) Set the Gas ON/OFF Knob (15) to “GAS ON” position.
6) Push the Ignition Button (17) of the flame failure device and press the Ignition Lever (16) of the piezo
lighter. The pressing of the Ignition Lever has to be repeated until the gas is lit at the burner.
7) Release the Ignition Button about 20 seconds after the burner flame has been on.
IMPORTANT
As air may be present in the gas lines at the first ignition, it may be necessary to repeat the starting-up
ignition procedure.
8) Turn the Gas Temperature Control Knob (5) to “COLDEST” setting.
9) If the cabinet is found too cold, turn the Gas Temperature Control Knob to a warmer setting.
3-2 Electric Operation (A.C.: 117V, D.C.: 12V)
To startup the refrigerating operation using electricity:
1) Be sure the refrigerator is level. A spirit level is supplied with the refrigerator. Place this level in the ice
making compartment to check the level of the refrigerator front to back and side to side.
2) Open the service access door.
3) Plug in the power cord to the 117V supply receptacle.
4) Turn the Gas ON/OFF Knob (15) to “GAS OFF” position, and slide the Electric DC-AC-OFF Slide
Switch (14) to left: “AC or DC”. Be sure to locate the slide head just below the AC or DC marking,
respectively, according to the electric current selected.
5) Turn the Electric Temperature Control Knob (6) to “COLDEST” setting.
6) In case the cabinet is found too cold, turn the Electric Temperature Control Knob (6) to a warmer
setting.