ELEMENTI OCK45-NG01-DE Manuel utilisateur

Manual No.: ENGE4501-DE-A0
Natural Gas Conversion Kit
OCK45-NG01-DE
DANGER
FIRE OR EXPLOSION HAZARD
If you smell gas:
• Shut off gas to the appliance.
• Extinguish any open flame.
• If odor continues, leave the area immediately.
• After leaving the area, call your gas supplier or
fire department.
Failure to follow these instructions could result in
fire or explosion,which could cause property
damage, personal injury, or death.
!
WARNING
!
IMPORTANT
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
!
Contact Elementi for Technical Support.
EN
This conversion kit shall be installed by a
qualified service agency in accordance with
the manufacturer’s instructions and all
applicable codes and requirements of the
Authority Having Jurisdiction. If the
information in these instructions is not
followed exactly, a fire, explosion or
production of carbon monoxide may
result causing property damage, personal
injury or loss of life. The qualified service
agency is responsible for the proper
installation of this kit. The installation is not
proper and complete until the operation of
the converted appliance is checked as
specified in the manufacturer’s instructions
supplied with the kit.
OFG101 OFG103 OFG104 OFG105 OFG110 OFG121
OFG126 OFG127 OFG128 OFG139 OFG145 OFG147

Conversion Warning ----------------------------------------------------------------------------------2
Specification --------------------------------------------------------------------------------------------3
Important Safety Information -----------------------------------------------------------------------4
Parts List ------------------------------------------------------------------------------------------------5
Natural Gas Conversion Instruction-------------------------------------------------------------- 6
Lighting Instructions ---------------------------------------------------------------------------------16
TABLE OF CONTENTS
2 / 36
CONVERSION WARNING
This appliance was converted on_______________________________ (DD/MM/YY)
to Natural gas by ____________________________________________________
(Name and address of organization making this conversion)
which accepts the responsibility that this conversion has been properly made.
After converting this fire table, this tag must be hung from the center of the control
panel with the provided cable.
WARNING
!
- Only the manufacturer’s conversion kit can be used.
- This conversion kit shall be installed by a qualified service agency
in accordance with the manufacturer’s instructions and all applicable
codes and requirements of the Authority Having Jurisdiction.
- Please follow the manufacturer’s instruction strictly.
- Do not attempt to convert or modify this applicance by your own.

3 / 36
Conversion Kit
Model No.: Serial Number:
Manufacturer ELEMENTI INDUSTRIAL (XIAMEN) CO., LTD.
Appliance Category
Gas type/Gas Pressure
Heat Imput
Injector Size
Destination Countries
Gas Connection Size
BE, BG, CY, CZ,
DK,EE, FI, FR,
GB, GR, HR,HU,
IT, LT, LU,LV,MT,
NL, NO, RO, SE,
SI, SK, TR
AT, CH, CZ, DE,
LU, SK
BE, CH, CY, CZ, ES, FR, GB, GR, IE,
IT, LT, LU, LV, PT, SI, SK, TR
AT,BG,CH,CY,CZ,
DK,EE,ES,FI,FR,
GB,GR,IE,IT,LT,
LV,NO,PT,RO,SE,
SI,SK
1.77mm
I3B/P(30) I3B/P(50) I3+(28-30/37) I2H
G30 Butane and
G31 Propane at
30mbar
G30 Butane and
G31 Propane at
50mbar
G30 Butane
at 28-30mbar
G31 Propane
at 37mbar
G20 Natural gas
at 20mbar
13.2KW(G30:960.0g/h;G31:943.3g/h)
1.53mm 1.77mm 2.96mm
RP 1/2” Other:
1. The use of this appliance in enclosed areas is
DANGEROUS and is PROHIBITED
2. For use outdoors or in amply venlated areas.
3. An amply venlated area must have a minimum
of 25 % of the surface area open.
4. The surface area is the sum of the walls surface.
SPECIFICATION
OCK45-NG01-DE

IMPORTANT SAFETY INFORMATION
!WARNING FIRE TABLE IS FOR OUTDOOR USE ONLY
IF YOU SMELL GAS
• Shut off gas supply to the fire table.
• Extinguish any open fame.
• Do not try lighting any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone.
• Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and repair should be done by a qualified service person. The appliance should be
inspected before use and at least annually by a qualified service person. More frequent cleaning may
be required as necessary. It is imperative that the control compartment, burners, and circulating air
passageways of the appliance are kept clean.
• WARNING: Installation and service must be performed by a qualified installer, service agency or gas
supplier.
• WARNING: Failure to follow with the safety warnings and precautions in this manual may result in
serious bodily injury or death, a fire or an explosion causing damage to property.
• IMPORTANT NOTICE: Read and understand all warnings and precautions prior to assembly and
use your gas fire table. Improper installation, adjustment, alteration, service or maintenance can
cause injury or property damage.
4 / 36
!This conversion kit is for chnging a propane / butane / LPG fire table into a Natural Gas
Fire Table.

PARTS LIST
5 / 36
No. Description & Quantity No. Description & Quantity
NG Valve & Brass Fitting A 1 set NG Orifice Spud 2.96 1 pc
Hexagon screwdriver( for knob use) 1 pc
Gas pressure and orifice plaque 1 pc
Warning plaque 1 pc
Natural gas lighting instruction 1 pc
Screws M4x10mm ( for valve use) 2 pcs
Conversion Kit Manual 1 pc
Brass Fitting B 1 pc
1 2
3 4
5 6
7 8
Brass Fitting A
NG Valve
Kette
1 Stck

NATURAL GAS CONVERSION INSTRUCTION
1ENSURE THE UNIT IS OFF AND COMPLETELY COOL, AND THE GAS
SUPPLY TO THE UNIT IS TURNED OFF.
!WARNING
Disconnecting the Gas Tank
Make sure the valve on the gas tank is OFF.
2Remove lava rock from burner pan area carefully.
Fire Table
3
Fire
Table
Lay down blanket or cardboard to avoid
damaging the finish, carefully tilt unit on
its side.
Blanket or cardboard
6 / 36

NATURAL GAS CONVERSION INSTRUCTION
4
7 / 36
A) Find out the hole to the left of the knob, insert it with the hexagon wrench
which provided in the conversion kit, rotate counterclockwise to loosen the
knob from the LP safety valve.
B) Then hold the knob with your hand, pull it forward, and remove the knob.
C) Remove the screws on both sides of the knob with a screwdriver and
take good care of them to avoid losing. (in case of losing, we have provided
additional spare screws in the accessory package).
Screws

NATURAL GAS CONVERSION INSTRUCTION
5
8 / 36
Remove the LP safety valve from the control panel, and disconnect the
thermocouple and both 2 sides of bellows from the LP safety valve.
BEFORE
AFTER
Thermocouple
Bellows
Brass Fitting A
Bellows
LP Safety Valve

NATURAL GAS CONVERSION INSTRUCTION
9 / 36
6
A) Find the NG safety valve from the conversion kit( which is labeled with
"NATURAL GAS VALVE"). The brass fitting A has assembled on the NG
safety valve. see FIG. A
Labeled “Natural Gas Valve”
Brass fitting A
FIG. A
Natural Gas Valve
B) Reconnect the bellows to the NG safety valve, and lock tightly.
C) Reconnect the thermocouple to the NG safety valve (After hand
tightening, use the wrench to force 90°. Do not over tighten).
There are 2 arrows on the NG safety valve, one is for gas inlet (connect
with the bellows in the direction of the Gas Supply), the other one is
for gas outlet (connect with bellows in the direction of the burner).
Failure to follow the instructions could result in fire or explosion,
which could cause property damage, personal injury, or death.
IMPORTANT
!
Gas inlet
Gas outlet
NG Valve
Bellows
Brass fitting A
Bellows
Connect to
gas supply
Gas inlet
Gas outlet
Brass fitting A
Thermocouple

NATURAL GAS CONVERSION INSTRUCTION
10 / 36
AFTER
BEFORE
Thermocouple
Bellows
Brass Fitting A
Bellows
LP Safety Valve
When connecting the bellows, please ONLY clockwise the brass joint on the bellows.
Do not rotate the stainless steel tube.
Excessive rotation of the stainless steel tube will cause the gas pipe to twist or break,
causeing gas leaks.
WARNING
Brass joint
SS tube
Brass joint
!
Ce manuel convient aux modèles suivants