8
Connect a PGM device to the PGM output (see Figure 3-1). PGM control configuration
ust be defined accordingly at each PGM’s progra ing para eters – please refer to
the iConnect 2-Way Control Syste ’s installation anual.
6.5. Backup Battery Connection
Insert the backup battery into its place and connect the lead connector to the backup
battery jack on the circuit board, see Figure 3-1.
Caution:
• The circuit board is designed to work with all approved 12VDC,7Ah sealed lead batteries as a
backup or the primary power supply in time o main power ailure.
• The circuit board is designed with reverse polarity protection on the battery charging circuit.
However, prolonged improper connection o the battery to the circuit board will result in damage.
• The battery is not supplied with the 2-Way Wireless I/O Expander Module.
• The rechargeable battery should be charged or at least 72 hours.
• Battery presence is checked every 10 seconds.
• There is a risk o explosion i a battery is replaced with an incorrect type.
• Dispose o used batteries according to the proper instructions.
• Battery in product shall be replaced every 3-5 years. No maintenance is needed.
• The power should remain disconnected until all connections have been made and checked or
accuracy.
6.6. Completing the Installation
To co plete the installation:
1. Mount the 2-Way Wireless I/O Expander Module back panel to the wall using
affixing screws, see Figure 5-2.
2. Connect the 2-Way Wireless I/O Expander Module to the AC ains power, see
Figure 6-1.
Caution:
• When the circuit board is powered on, mains voltage is present on the main PCB.
• To prevent risk o electric shock, disconnect all power (AC trans ormer and battery)
be ore servicing.
• Under no circumstances should mains power be connected to the PCB other than
through the main terminal block.
• A readily accessible disconnection device shall be incorporated in the building
installation wiring.
• For continued protection against risk o ire, replace uses only with uses o the same
type and rating.
3. Before closing the front cover and securing the locking screw, proceed to
Registering the 2-Way Wireless I/O Expander Module, below.