Smoke
Call point
Beacon base
Output module
Damper shutdown
HVAC shutdown
Gas sensor Gas sensor Gas sensor
EOL
Conventional Zone 1
Conventional Zone 2
EOL
Level Detection
Isolating base
Heat
SmokeSmoke
Call point Multi sensor
Integrated
base sounder
Isolating base
CO Fire
detector
EOL
ZONE MONITOR
Conventional Zone
Smoke
Gas detector
interface Gas detector
interface
Gas detector
interface
Isolating base
Switch monitor
Door switches
Heat
Smoke Heat
Remote
indicator
Isolating base
Smoke
Smoke
Isolating base
Zone monitor
EOL
Conventional Zone
LOOP 1
AC MAIN AUX
1 2 3
17 18
DC
POWER IN
DC CHR FLT
BATT
POWER OUT
PRE DEL FLT
FIRE / GASALARM
MUTE ISOL DEL TEST
PANEL/ DEVICE STATUS
EVAC
4 5 6 7 8 9 10 11 12 13 14 15 16
19 20 21 22 23 24 25 26 27 28 29 30 31 32
+
_
ENT MENU EVAC MUTE RESET LAMP
TEST
FIRE / GAS DETECTOR REPEATER
E
D
COMMSALM
MANUFACTURED BY ELECTRONIC DEVICES LTD.,MALVERN, ENGLAND.
ZONES 1 - 32
ALM
POWER- IN LAMPS
POWER- OUT LAMPS
FIRE/ GAS LAMPS
-
PANEL/ DEVICE STATUSLAMPS
AC- AC SUPPLY INPUT HEALTHY
DCMAIN - MAIN DC INPUT HEALTHY
DCAUX - OPTIONAL AUXILIARYDC INPUT
HEALTHY
DC- DC OUTPUT SUPPLY HEALTHY
BATTCHR - BATTERYCHARGING
BATTFLT- BATTERYFAULT/ BATTERY
REQUIRESEXTERNAL CHARGING
PRE- PRE-ALARM LEVEL
DEL- DELAYED ALARM OPERATED
FLT- PANEL/ LOOP / DEVICE FAULT
EVAC- EVACUATE
MUTE- SOUNDERS HAVE BEEN SILENCED
ISOL- ISOLATED, ONE OR MORE ZONES
HAVE BEEN INHIBITED
DEL- ONE OR MORE DEVICE OUTPUTS
HAVEBEEN DELAYED
TEST- WHILST IN TEST MODE THE
ZONEUNDER TEST WILL NOT INITIATE
ALARMS. REMAINING ZONES WILL
CONTINUETO FUNCTION NORMALLY
COMMS- COMMUNICATION FAULT
FIREALARM, GAS ALARM
-USE TO SCROLL THROUGH CURRENT
EVENTSAND NAVIGATEMENU
-USE TO NAVIGATEMENU
-INCREMENT / DECREMENT
ENT- ENTER / CONFIRM
MENU- MAIN MENU / PREVIOUS MENU
EVAC- EVACUATEOPERATES ALL OUTPUT
DEVICES
MUTE- SILENCE SOUNDERS
RESET- RESET SYSTEM TO NORMAL
CONDITIONFOLLOWING ALARM / FAULT
LAMPTEST - PRESS TOTEST ALL LAMPS
KEYS
+/-
14:29 27/11/06 ED816 ALARM SYSTEM
NO OF DETECTORS IN ALARM: 1 IN 1 ZONES
DETECTOR 1/ 1:
14:27
ISOL ZONES 0
27/11/06 ENGINE ROOM
HEAT DETECTOR LOOP 2 ID 035 ZONE 2
PRE ALARMS 0 FAULTS 0
EOL
Fault monitored Flameproof Beacons and Sounders
Conventional Zones 1and 2
can be Safe Area, Hazardous Area,
Fire or level detection.
AC MAIN AUX
1 2 3
17 18
DC
POWER IN
DC CHR FLT
BATT
POWER OUT
PRE DEL FLT
FIRE / GASALARM
MUTE ISOL DEL TEST
PANEL/ DEVICE STATUS
EVAC
4 5 6 7 8 9 10 11 12 13 14 15 16
19 20 21 22 23 24 25 26 27 28 29 30 31 32
+
_
ENT MENU EVAC MUTE RESET LAMP
TEST
FIRE / GAS DETECTOR REPEATER
E
D
COMMSALM
MANUFACTURED BY ELECTRONIC DEVICES LTD.,MALVERN, ENGLAND.
ZONES 1 - 32
ALM
POWER- IN LAMPS
POWER- OUT LAMPS
FIRE/ GAS LAMPS
-
PANEL/ DEVICE STATUSLAMPS
AC- AC SUPPLY INPUT HEALTHY
DCMAIN - MAIN DC INPUT HEALTHY
DCAUX - OPTIONAL AUXILIARYDC INPUT
HEALTHY
DC- DC OUTPUT SUPPLY HEALTHY
BATTCHR - BATTERYCHARGING
BATTFLT- BATTERYFAULT/ BATTERY
REQUIRESEXTERNAL CHARGING
PRE- PRE-ALARM LEVEL
DEL- DELAYED ALARM OPERATED
FLT- PANEL/ LOOP / DEVICE FAULT
EVAC- EVACUATE
MUTE- SOUNDERS HAVE BEEN SILENCED
ISOL- ISOLATED, ONE OR MORE ZONES
HAVE BEEN INHIBITED
DEL- ONE OR MORE DEVICE OUTPUTS
HAVEBEEN DELAYED
TEST- WHILST IN TEST MODE THE
ZONEUNDER TEST WILL NOT INITIATE
ALARMS. REMAINING ZONES WILL
CONTINUETO FUNCTION NORMALLY
COMMS- COMMUNICATION FAULT
FIREALARM, GAS ALARM
-USE TO SCROLL THROUGH CURRENT
EVENTSAND NAVIGATEMENU
-USE TO NAVIGATEMENU
-INCREMENT / DECREMENT
ENT- ENTER / CONFIRM
MENU- MAIN MENU / PREVIOUS MENU
EVAC- EVACUATEOPERATES ALL OUTPUT
DEVICES
MUTE- SILENCE SOUNDERS
RESET- RESET SYSTEM TO NORMAL
CONDITIONFOLLOWING ALARM / FAULT
LAMPTEST - PRESS TOTEST ALL LAMPS
KEYS
+/-
14:29 27/11/06 ED816 ALARM SYSTEM
NO OF DETECTORS IN ALARM: 1 IN 1 ZONES
DETECTOR 1/ 1:
14:27
ISOL ZONES 0
27/11/06 ENGINE ROOM
HEAT DETECTOR LOOP 2 ID 035 ZONE 2
PRE ALARMS 0 FAULTS 0
Up to 8 repeaters
Sounder circuit 1
Sounder circuit 2
Sounder circuit 3
Engineers PC
Alarm relay contacts
Pre - Alarm relay contacts
Delayed Alarm relay contacts
Fault relay contacts
Auxiliary relay contacts
Auxiliary relay contacts
Auxiliary relay contacts
HWFD relay contacts to
additional Fire alarm Panels
INTRODUCTION
The ED816A Analogue Addressable Alarm system is capable of giving
Fire, Gas, Water and/or Engine alarms, operate Fire Fighting
equipment and is approved to Lloyds Register ENV1, 2, and 3.
It is capable of driving up to 252 addressable devices per system in 2
loops of 126 devices per loop.
The ED816A has an enclosure 365 x 340 x 110mm weighing 7.5Kg.
Contact Electronic devices limited on:
Tel: +44 (0)1684 891500
Fax: +44 (0)1684 891600
LOOP 2
-3-
AC MAIN AUX
1 2 3
17 18
DC
POWER IN
DC CHR FLT
BATT
POWER OUT
PRE DEL FLT
FIRE / GAS ALARM
MUTE ISOL DEL TEST
PANEL/ DEVICE STATUS
EVAC
4 5 6 7 8 9 10 11 12 13 14 15 16
19 20 21 22 23 24 25 26 27 28 29 30 31 32
+
_
ENT MENU EVAC MUTE RESET LAMP
TEST
FIRE / GAS DETECTOR TYPE ED816A
E
D
COMMS
ALM
MANUFACTURED BY ELECTRONIC DEVICES LTD.,MALVERN, ENGLAND.
ZONES 1 - 32
ALM
POWER- IN LAMPS
POWER- OUT LAMPS
FIRE/ GAS LAMPS
-
PANEL/ DEVICE STATUSLAMPS
AC- AC SUPPLY INPUT HEALTHY
DCMAIN - MAIN DC INPUT HEALTHY
DCAUX - OPTIONAL AUXILIARY DC INPUT
HEALTHY
DC- DC OUTPUT SUPPLY HEALTHY
BATTCHR - BATTERY CHARGING
BATTFLT - BATTERYFAULT / BATTERY
REQUIRESEXTERNAL CHARGING
PRE- PRE-ALARM LEVEL
DEL- DELAYED ALARM OPERATED
FLT- PANEL / LOOP / DEVICE FAULT
EVAC- EVACUATE
MUTE- SOUNDERS HAVE BEEN SILENCED
ISOL- ISOLATED, ONE OR MORE ZONES
HAVE BEEN INHIBITED
DEL- ONE OR MORE DEVICE OUTPUTS
HAVEBEEN DELAYED
TEST- WHILST IN TEST MODE THE
ZONEUNDER TEST WILL NOT INITIATE
ALARMS. REMAINING ZONES WILL
CONTINUETO FUNCTION NORMALLY
COMMS- COMMUNICATION FAULT
FIREALARM, GAS ALARM
-USE TO SCROLL THROUGH CURRENT
EVENTSAND NAVIGATE MENU
-USE TO NAVIGATE MENU
-INCREMENT / DECREMENT
ENT- ENTER / CONFIRM
MENU- MAIN MENU / PREVIOUS MENU
EVAC- EVACUATE OPERATESALL OUTPUT
DEVICES
MUTE- SILENCE SOUNDERS
RESET- RESET SYSTEM TO NORMAL
CONDITIONFOLLOWING ALARM / FAULT
LAMPTEST - PRESSTO TEST ALL LAMPS
KEYS
+/-
14:29 27/11/06 ED816 ALARM SYSTEM
NO OF DETECTORS IN ALARM: 1 IN 1 ZONES
DETECTOR 1/ 1:
14:27
ISOL ZONES 0
27/11/06 ENGINE ROOM
HEAT DETECTOR LOOP 2 ID 035 ZONE 2
PRE ALARMS 0 FAULTS 0
ED816A Addressable Fire and gas detection Installation manual 8-9-08 Rev-a