Electro Industries SM1-16 Manuel utilisateur

SubstationMultiplexor
SM1-16
with
ETHERNET OPTION
Electro Industries/GaugeTech
Installation & Operation Manual
Revision 1.01
August 14, 2002
Doc # E113-7-07-101
1800 Shames Drive
Westbury, New York 11590
Tel: 516-334-0870 Fax: 516-338-4741
“The Leader in Web Accessed Power Monitoring ”

Substation Multiplexor SM1-16
with Ethernet Option
User Manual
Revision 1.01
Published by:
Electro Industries/GaugeTech
1800 Shames Drive
Westbury, NY 11590
All rights reserved. No part of this
publication may be reproduced or
transmitted in any form or by any
means, electronic or mechanical,
including photocopying, recording,
or information storage or retrieval
systems or any future forms of
duplication, for any purpose other
than the purchaser’s use, without the
expressed written permission of
Electro Industries/GaugeTech.
© 2002
Electro Industries/GaugeTech
Printed in the United States of
America.
eElectro Industries/GaugeTech Doc # E113-7-07-101 I

eElectro Industries/GaugeTech Doc # E113-7-07-101 II
Customer Service and SupportCustomer Service and Support
Customer support is available 9:00 am to 4:30 pm, eastern standard time, Monday through Friday.
Please have the model, serial number and a detailed problem description available. If the problem
concerns a particular reading, please have all meter readings available. When returning any merchandise
to EIG, a return authorization number is required. For customer or technical assistance, repair or
calibration, phone 516-334-0870 or fax 516-338-4741.
Product WarrantyProduct Warranty
Electro Industries/GaugeTech warrants all products to be free from defects in material and workmanship
for a period of four years from the date of shipment. During the warranty period, we will, at our option,
either repair or replace any product that proves to be defective.
To exercise this warranty, fax or call our customer-service department. You will receive prompt
assistance and return instructions. Send the instrument, transportation prepaid, to EIG at 1800 Shames
Drive, Westbury, NY 11590. Repairs will be made and the instrument will be returned.
Limitation of WarrantyLimitation of Warranty
This warranty does not apply to defects resulting from unauthorized modification, misuse, or use for any
reason other than electrical power monitoring.
OUR PRODUCTS ARE NOT TO BE USED FOR PRIMARY OVER-CURRENT
PROTECTION. ANY PROTECTION FEATURE IN OUR PRODUCTS IS TO BE USED FOR
ALARM OR SECONDARY PROTECTION ONLY.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR
IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. ELECTRO INDUSTRIES/GAUGETECH
SHALL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL OR CONSEQUENTIAL
DAMAGES ARISING FROM ANY AUTHORIZED OR UNAUTHORIZED USE OF ANY
ELECTRO INDUSTRIES/GAUGETECH PRODUCT. LIABILITY SHALL BE LIMITED TO
THE ORIGINAL COST OF THE PRODUCT SOLD.
Statement of CalibrationStatement of Calibration
Our instruments are inspected and tested in accordance with specifications published by Electro
Industries/GaugeTech. The accuracy and a calibration of our instruments are traceable to the National
Institute of Standards and Technology through equipment that is calibrated at planned intervals by
comparison to certified standards.
DisclaimerDisclaimer
The information presented in this publication has been carefully checked for reliability; however, no
responsibility is assumed for inaccuracies. The information contained in this document is subject to
change without notice.

eElectro Industries/GaugeTech Doc # E113-7-07-101 III
About Electro Industries/GaugeTechAbout Electro Industries/GaugeTech
Electro Industries/GaugeTech was founded in 1973 by Dr. Samuel Kagan. Dr. Kagan’s first innovation,
an affordable, easy-to-use AC power meter, revolutionized the power-monitoring field. In the 1980s Dr.
Kagan and his team at EIG developed a digital multifunction monitor capable of measuring every aspect
of power. EIG further transformed AC power metering and power distribution with the Futura+ device,
which supplies all the functionality of a fault recorder, an event recorder and a data logger in one single
meter. Today, with the Nexus 1250 and a wide variety of dependable solutions, EIG is a leader in the
development and production of power-monitoring products. All EIG products are designed,
manufactured, tested and calibrated at our facility in Westbury, New York.
EIG Product Applications
nMultifunction power monitoring
nSingle and multifunction power monitoring
nPower-quality monitoring
nOnboard data logging for trending power usage and quality
nDisturbance analysis
Nexus 1250
n0.04% Watt-hour Accuracy
nExpandable I/O and Trending
nDemand Integration Intervals
nHarmonics to the 127th Order
Futura+ Series
nPower-quality monitoring
nHigh-accuracy AC metering
nOnboard data logging
nOnboard fault and voltage recording
DM Series
nThree-phase multifunction monitoring
nWattage, VAR and amperage
nModbus, Modbus Plus, DNP 3.0 and Ethernet protocols
nAnalog retransmit signals (0–1 and 4–20mA)
Single-Function Meters
nAC voltage and amperage
nDC voltage and amperage
nAC wattage
nSingle-phase monitoring with maximum and minimum demands
nTransducer readouts
Portable Analyzers
nPower-quality analysis
nEnergy analysis

Table
of
Contents
Chapter 1: Ethernet Option Installation
1.1: Mounting Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1.2: Communication Connections . . . . . . . . . . . . . . . . . . . . . . . . 1-4
1.3: RS232 Wiring Details . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
1.4: RS485 Wiring Details . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
1.5: Communication Overview . . . . . . . . . . . . . . . . . . . . . . . . 1-10
1.6: Connecting the Substation Multiplexor Directly to a Computer . . . . . . . . . 1-11
1.7: Connecting to the Substation Multiplexor Using the Internal Modem . . . . . . 1-11
1.8: Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
Chapter 2: Ethernet Option Configuration
2.1: Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.2: Ethernet Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.3: Ethernet Option Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.4: Default IP Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.5: AutoIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.6: Setting the IP Address . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.7: Networking Configuration . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.8: Configuration Parameters . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Chapter 3: Ethernet Option Operation
3.1: Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.2: Alternate Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3.3: Using Windows®HyperTerminal with the Substation Multiplexor . . . . . . . . 3-3
3.4: Using EIG’s Futura Communicator with the Substation Multiplexor . . . . . . . 3-6
3.5: Command Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
3.6: Port Program Commands . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9
3.7: Port Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11
3.8: Unit Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12
3.9: Site ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12
3.10: Go to Throughput Mode . . . . . . . . . . . . . . . . . . . . . . . . . 3-12
3.11: Go to Boot Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12
3.12: Go to Mode Selection . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13
3.13: Password Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13
3.14: Contact Information for EIG . . . . . . . . . . . . . . . . . . . . . . . 3-14
Electro Industries/GaugeTech
Doc # E113-7-07-101 IV

Electro Industries/GaugeTech
Doc # E113-7-07-101 1-1
Chapter
1
Ethernet
Option
Installation
1.1:
Mounting
Information
QThe Substation Multiplexor with Ethernet Option is designed to mount in a standard, 19-inch panel
rack. Mounting for all Substation Multiplexors is the same, regardless of option selection. Use a #10
screw in each of the four slots on the flange to ensure that the unit is installed securely.
TToopp
VViieeww

Electro Industries/GaugeTech
Doc # E113-7-07-101 1-2
FFrroonntt
VViieeww

Electro Industries/GaugeTech
Doc # E113-7-07-101 1-3
SSiiddee
VViieeww

Electro Industries/GaugeTech
Doc # E113-7-07-101 1-4
Master Port for Ethernet
Standard RJ45. Set the
232(DCE) Network Switch
to Network when using
Ethernet.
Slave Ports 1 & 2
2-wire RS485
232(DCE) Network Switch for Master Port
When using Ethernet, set to Network.
When connecting directly to a computer from the RS232
Master Port, set to 232 (DCE).
Slave Ports 3–16
9-pin female RS232 ports.
Use a standard RS232 cable.
Power Supply
Relay (Detail)
Master Port RS232
For direct connection to a
computer.
BBaacckk
PPaanneell
1.2:
Communication
Connections
•All Slave Ports are factory-set to operate at 9600 baud and
the Master Ports are factory-set to operate at 57600 baud.
•The maximum baud rate for all Slave Ports is 57600.
••The baud rate for a Master Port is 57600.
Com
N.O.
N.C.

Electro Industries/GaugeTech
Doc # E113-7-07-101 1-5
Slave Port LEDs
Shows which Slave Port the Multiplexor is programmed to use.
FFrroonntt
PPaanneell
Network Link LED
RxD/TxD/RTS LEDs
RxD/TxD LEDs illuminate when the
unit is Receiving or Transmitting Data.
Power Indicator
Table des matières
Manuels Multiplexeur populaires d'autres marques

ADTRAN
ADTRAN Frameport 768 Manuel utilisateur

Elo TouchSystems
Elo TouchSystems E247 Manuel utilisateur

Paradyne
Paradyne Hotwire 8786 Manuel utilisateur

RFL Electronics
RFL Electronics 9508D UCC Manuel utilisateur

Miranda
Miranda AMX-101i Mode d’emploi

ShipModul
ShipModul MiniPlex-AIX NMEA-0183 Manuel utilisateur