This surveys the functioning of the close-coupled pump and stops it if there are anomalies in the parts controlled
by probes.
It has been designed to be installed in cavities in dashboards, electric panels, etc.
NOTICES
Warning:
adhere closely to the following advice
- Always install under other equipment which produces or spreads heat.
- Always follow the Circuit Diagram on pages 6-7 when making connections.
- Check that the line loading and the consumption of the connected equipment are compatible with the
technical characteristics on page 12.
- All technical interventions must be performed with the engine stationary and terminal 50 of the
starter motor disconnected.
- Never use a battery charger for the emergency start-up, this could damage the equipment.
- To protect the safety of persons and the equipment, before connecting an external battery charger,
disconnect the electrical plant terminals from the battery poles.
NOTE: THE HOLE IN THE CASING USED TO INSTALL THE PROTECTION DEVICE COULD INFLUENCE THE
LEVEL OF PROTECTION OF BOTH. STEPS MUST BE TAKEN TO MAINTAIN THE ORIGINAL LEVEL
OF PROTECTION.
THIS DEVICE IS NOT SUITABLE FOR OPERATING IN THE FOLLOWING CONDITIONS:
- Where the environmental temperature is outside the limits indicated in the .
- Where there are high levels or heat from radiation caused by the sun, ovens or the like.
- Where there is the risk of fire or explosions.
- Where the device can receive strong vibrations or knocks.
Technical Data on page 12
The following maintenance operations should be performed every week:
- check that the indicators function;
- check the batteries;
- check that the conductors are tight, check the condition of the terminals.
CONDUCTION AND MAINTENANCE
ELECTROMAGNETIC COMPATIBILITY
This protection device functions correctly only if inserted in plants which conform with the CE marking standards;
it meets the exemption requirements of the standard EN50082-1 but it cannot be excluded that malfunctions
could occur in extreme cases due to particular situations.
The installer has the task of checking that the disturbance levels are within the requirements of the standards.
YOUR ELECTRICAL TECHNICIAN CAN ASK US ANYTHING ABOUT THIS PROTECTION
DEVICE BY TELEPHONING ONE OF OUR TECHNICIANS
UNLESS WE MAKE A WRITTEN DECLARATION STATING THE CONTRARY, THIS PROTECTION DEVICE IS
NOT SUITABLE FOR USE AS A CRITICAL COMPONENT IN EQUIPMENT OR PLANTS RESPONSIBLE FOR
KEEPING PERSONS OR OTHER LIVING BEINGS ALIVE
2GB DIM-807/00 /4
IRRIGATION CLOSE-COUPLED PUMP PROTECTION DEVICE
TYPE DIM-807/00