ELCO(Tianjin) Electronics Co.,Ltd
NO.12, 4th XEDA Branch Road, Xiqing Economic Development Area, Tianjin, P.R.China
Tel: +86 22 23888288
Fax: +86 22 23788399
www. elco-holding .com
Germany Tel +49 70626599-260
Germany Fax +49 70626599-261
Manufactured in China
TEACH
DOWN
UP
STEP Long pressTEACHEnter the menu interface
7.OPERATION GUIDE
1-point
teaching
2-point
teaching
3-point
teaching
Teaching
output
usually
detected
1.Ranging diaplay
Measurement interfaceShow actual measurement distanceresolution is 0.1mm(KL70 is 10μm)when the
distance is out of detected distance,it diaplays“----”
Display description:Take the center distance as 0 point,the distance less than the center is positive,the distance greater than the center
is negative,and the displayed value is the offset value.
2.Menu and key operation
2.1 Enter the menuLong pressTEACH above 3s when it is in the measurement interfaceenter the menu interface
Exit menuLong pressTEACH above 3s when it is in the menu interfaceor no key operation for 20sreturn to measurement interface
2.2 Menu operation
Enter the menu interface,diaplay the main menu,switch the menu options by pressing the up/down key.
On the main menu interface,enter the submenu options by short pressing TEACH key.Unter the submenu,short press up/down to select
the parameter.Short press the TEACH key to confirm and return to the previous main menu.
1)Teaching output
The main menu shows“SEnS”press TEACH to enter the submenu;
Submenu items“__|”usually detected modedefault“_N_.1”1-point teaching window comparison mode
“_N_.2”2-point teaching window comparison mode“_N_.3”3-point teaching window comparison mode“nid”midpoint teaching mode.
The above teaching modes are detailed in 6.Teaching mode description.
2)Set response speed:
The main menu shows“SPEd”press TEACH to enter the submenu;
Submenu items“H.rSo”high precision 15ms;“Std”standard 5msdefault; “FASt”high speed 1.5ms
3)Set digital output ditection
The main menu shows“ L-d”press TEACH to enter the submenu;
Submenu items“ L-on”luminousdefault“d-on”dark pass;
4)Anti-shake settings
The main menu shows“HySt”press TEACH to enter the submenu;
Submenu initial diaplay“ 0.1”,0.1mm is hysteresis distanceshort press UP/DOWNstep 0.1mm(KL70 is 0.01mm)long press
UP/DOWN above 3sstep 1mm(KL70 is 0.1mm)Setting range is 0~5mminitial value is 1mm(KL70 is 0.1mm)
5)Digital output keep setting
The main menu shows“dELy”press TEACH to enter the submenu;
Submenu initial diaplay“ 0”,no delayshort press UP/DOWNstep 10mslong press UP/DOWN above 3sstep 100ms
Setting range is 0~1000msinitial value is 0ms
6)Set digital output type
The main menu shows“ P-n”press TEACH to enter the submenu;
Submenu items“ nPn”NPN output modedefault“ PnP”PNP output mode.
7)Analog output mode setting
The main menu shows“ Ao.N”press TEACH to enter the submenu;
Submenu items“ioUt”current output modedefault“voUt”voltage output mode.
8)Set analog output ditection
The main menu shows“Ao.d”press TEACH to enter the submenu;
Submenu items“Ao-F”forwarddefault“Ao-r”reverse
Forward direction:short distance corresponds to small current/voltage,long distance corresponds to large current/voltage.The reverse
is the opposite.
9)Set analog output range
The main menu shows“Ao.S”press TEACH to enter the submenu;
Submenu items“FULL”full scale modedefault“rAng”window mode
When set to window mode,the analog output range can be set through the two-point teaching mode.
10)Set display mode
The main menu shows“diSP”press TEACH to enter the submenu;
Submenu items“norN”normal displacement modedefault“rEv”reverse displacement mode“dist”distance mode.
11)Environmental protection settings
The main menu shows“ Eco”press TEACH to enter the submenu;
Environmental protection function noteAfter the function is turned on,the LED will automatically turn off the display in
30s without any button.
12)External output settings
The main menu shows“InPt”press TEACH to enter the submenu;
Submenu items“L-oF”stop cast light“L-on”turn on cast light“Erig”external inputdefault
External input noteWhen the external input is low,stop cast lightno external input,default turn on cast light
13)Reset settings
The main menu shows“rSEt”press TEACH to enter the submenu;
Submenu items“ no”do not perform reset“ yES” perform resetrestore default settings.
2.3 Key lock function
Turn on key lock:In the measurement interfacepress the UP and DOWN keys at the same time for more than 3s
the interface displays “Lc.on”and the menu function is invalid at this time.
Turn off the key lock:After the key lock is turned on,press the UP and DOWN keys at the same time for more than 3s
the interface displays “Lc.FA”press the UP and DOWN keys at the same time for more than 3s again
the interface displays “Lc.oF”and the key function are restored.
TEACH
15ms 5ms 1.5ms
UP
DOWN
TEACH
UP
DOWN
UP/
DOWN
(TEACH)
UP/
DOWN
(TEACH)
UP/
DOWN
(TEACH) (TEACH) (TEACH) (TEACH)
TEACH
UP
DOWN
UP/
DOWN
(TEACH)
TEACH
DOWN
UP/
DOWN
UP
TEACH
TEACH
NPN PNP
UP/
DOWN
(TEACH)
UP
DOWN
UP
DOWN
Analog output mode setting
TEACH
UP/
DOWN
(TEACH)
UP
DOWN
TEACH
UP/
DOWN
(TEACH)
UP
DOWN
TEACH
UP
DOWN
UP/
DOWN
(TEACH)
TEACH
UP
DOWN
UP/
DOWN
(TEACH)
UP/
DOWN
(TEACH)
TEACH
UP/
DOWN
(TEACH)
TEACH
DOWN
UP/
DOWN
(TEACH)
UP/
DOWN
(TEACH)
TEACH
DOWN
UP/
DOWN
(TEACH)
UP/
DOWN
UP/
DOWN
UP/
DOWN
Set response
speed
Set digital output ditection
Anti-shake settings
Set analog
output ditection
Set analog
output range
Set display mode
Environmental
protection settings
External output settings
Reset settings
dark pass
luminous
reverseforward
window mode
full scale
normal reverse distance
close
open
external input
stop
cast light turn on
cast light
perform reset
do not
perform
reset
short pressUP/DOWNstep0.1mm(KL70 is 0.01)long pressUP/DOWN
above 3sstep1mm(KL70 is 0.1)
short pressUP/DOWNstep10mslong pressUP/DOWN above 3s
step100ms
Set digital output type
Digital output keep setting no delay
Current output
mode
Voltage output
mode
midpoint
teaching