8
2)ECO switch
Energy conservation
When the energy-saving switch is in the energy-saving position, the
generator is in the energy-saving state. When disconnecting or using
low power, the engine automatically returns to a low speed state, thus
reducing engine fuel consumption.
Full speed
When the energy-saving switch is in full-speed position, the engine will
remain in a high speed state.
•In order to reduce the change of voltage, the energy saving
switch should be in the position of "full speed" when the
electrical equipment needs a large instantaneous power, or
when the generator is connected with the load of some high
power apparatus at the same time.
•When using 12 V DC output, put the energy-saving switch in
full-speed position.
•"Full speed" means that the energy-saving state is off and the
engine is always at high speed, which is suitable for the
situation when the load of electrical appliances varies greatly.
•In the non-overload state, the output cannot be restored by
pressing the reset key.
•After being switched off five times by the overload switch, the
generator must be restarted.