CAUT IO N!
A circuit breaker (250VAC, 10A) type C according to
EN60898-1 of load shall be installed in the fixed wiring for
protection.
Do not mount on conductive surface.
Do not open the enclosure frequently.
Turn off power when change the light sources.
High in-rush current would be caused when bulbs of certain
brands burned which might damage the unit permanently.
1 PACKAGE C ONTENTS
Patt er n
Patt er n
It em
It em
Quantity
Quantity
13
Please disconnect power completely and read the
entire instruction manual carefully before installation.
3 IN STAL LATI ON AND WIRING
Top vi ew Side v ie w
FIG.1-A
2 PRODUCT DESCRIPTION
2.1 Fe atu re s
3.1 Select a proper location
Motion
detector
Lens shield
(OS -36 0 / 300PA)
3.1.1 It is recommended to install the detector at the height of
2.5m. The detection range can reach up to a radius of
16m at the height of 2.5m (See FIG.2-A & FIG.2-B).
Installation and assembly of electrical equipment
must be carried out by qualified electricians.
Contact a qualified electrician in the event of fault
or break down.
INSTRUCTION MANUAL
TECHNICAL SPECIFICATIONS
220-240V~ 50/60Hz
Rated Voltage
Load
3.1.2.3 Pay attention to the walking direction in the test
proceeding (See FIG.4).
3.4 Installation procedure
This outdoor motion detector can be installed on wall directly &
recess corner with mounting bracket or on the ceiling directly or
on the European standard junction box.
FIG.9-A
Hook
Slot
When detector is standby under the auto mode, the
can be b yp as se d to t ur n the lig ht (s ) on f or 8 h ours by ser ie s
connecting a power supply switch.
detector
The operations are as under mentioned :
When the light is off, transfer the power supply switch from
“off → o n → of f → on” within 2sec, afterwards, light will
chan ge i ts s ta tu s fr om on 3se c & of f 2s ec & o n to c on firm th at
has entered into permanent on 8 hours mode.detector
When the light is on, transfer the power supply switch “off →
→ off → on” within 2sec, afterwards, light will turn off for
2sec, then turns on to confirm that detector has entered into
on 8 hou rs m od e.
on
permanent
In the on 8 hou rs m od e, t he can be s et t o
mode by transferring the power supply switch “off → on”
1sec, afterwards, light will turn off for 2sec. then detector
enters into auto mode and work with the knob settings.
permanent detector
auto
within
3.3 Wiring diagrams
3.3.1 Normal operation for lighting control (See FIG.5)
OUTDOOR PIR MOTION DETECTOR
for Lightin g or HVAC Automa tion C ontr ol
OS - / OS - 300 PA / OS -240PA 360PA
For li gh ti ng (w it h ju mp er wi re )
Incandescent lamp: Max. 2300W
AC Halogen lamp : Max. 1200W
LV Halo ge n la mp : M ax . 1000VA /
600W ( Co nv en ti onal)
Max. 9 00 W (E le ct ronic )
Fluorescent lamp : Max. 1000VA / 600W
(unc om pe ns at ed)
Max. 9 00 VA / 1 00 µF
(com pe ns at ed )
LED lamp(Driver) : Max. 400W
Ener gy S av in g : Ma x. 6 00VA / 4 00W
lamp ( in cl ud e CF L and PL la mp )
For HVAC (re mo ve j um per w ir e)
Max.10A(cosφ=1) for 2 50 VAC
Max. 5A f or 3 0V DC
Max.3A(cosφ=0.4) f or 2 50 VAC
OS -3 00PA
Lux
Adjustment
Auto Off
Adjustment
Time
Operatin g
Temperature
o o
-20 C to +50 C
Environmental
Protection
IP55
Detection Range
OS-360PA 360 ° , up t o 32m (R =1 6m )
at height of 2.5m
Φ
300° , up to R16m (frontal)/R14m(backward)
at height of 2.5m
OS -2 40PA 240° , u p to R 16 m
at height of 2.5m
(frontal)/R8m(backward)
Adjustable from approx. 5sec to 30min
and Test &
Adju st ab le f ro m ap prox. 5 Lux to “
and “ ” (l ea rn in g ra nge: 5Lu x - 500Lux)
& Holiday
” (∞)
Can be used to control lighting or HVAC devices (voltage free
contact).
Pulse count function to avoid the false triggering problem
caused by environment.
Excepting the provided Lux values, the ambient light level can
be read-in as the Lux value for more flexible application.
Manual override for lighting on 8hrs. is enabled by using an
external rocker switch to control or IR remote control.
Built-in 4 LEDs provide Warning / Watch function, which
enables the detector to guarantee complete surveillance or
warning respectively.
User friendly design of un-falling mounting base and plug-in
terminal block for installation convenience.
OS-360PA
Φ32m
Φ14m
Φ10m
16m
O
360
2.2 Di men si on (S ee FI G.1- A & FI G. 1-B & F IG.1 - C)
Wall mount: 150 x 90 x 84mm
84mm
79mm
Φ90mm
80mm
FIG.3
3.1.2.1 The optimal location for installation is at garden, corridor,
staircase, entrance, garage, public lavatory, outdoor
parking area, home and office, etc.
3.1.2.2 Since the detector responds to temperature change,
please avoid the following conditions:
Avoid pointing the detector toward the objects whose surfaces
are highly reflective, such as mirror, glass, etc.
Avoid mounting the detector near heat sources, such as heating
vents, air conditioners, lights, etc.
Avoid aiming the detector toward the objects which may be
swayed in the wind, such as curtain, tall plants, etc.
3.1.2 Helpful tips for installation
OPEN
OPEN
FIG.2-A
FIG.2-B
OS-240PA
OS-240PA / OS-300PA / OS-360PA
5
5
0
16m
16m
7
7
Top vi ew Side v ie w
O
240
FIG.5
FIG.13-A FIG.13-B
3.4.1.5
(See FIG.13-A) to shorten the detection range, or
O
turned leftward and rightward max. 90 horizontally
(See F IG.13- B) . Pl ea se a dj ust det ec to r he ad t o get the
desi re d de te ct ion fie ld .
O
Detector head can be adjusted downward max.40
FIG.11
FIG.12-A FIG.12-B
Non-dropping
screw
Bottom cover
Wal l mo un t Ce ili ng mount
Rub be r
gasket
O
90
O
90 O
90
O
40
FIG.8
Anchor
Wood Screw
Φ4x10mm
22
Wood Screw
Φ4x25.4mm
2
Jum p or wire
2
Lens shield
(OS-240PA)
3.4. 2 Co rn er / rece ss m ou nt wi th m ou nt ing b ra ck et
3.4.2.1 There are cable entry knock-outs at back and bottom
side s. S el ec t th e pr oper ho le s an d br ea k it thro ug h fo r
wiri ng. (S ee F IG.14- B & FI G.14 -C )
3.4.2.2 Break the desired screw knock-outs (See FIG.14-A). Then
fix th e mo un ti ng b ra cket on to r ec es s/ conne r wi th w oo d
scre ws ( Se e FI G. 15 -A & FI G.15 -B ), a nd f ix b ottom c ov er
on mou nt in g br ac ket (Se e FI G.16). Refer t o FI G.5-FI G.7
to con ne ct p ow er c ables , th en f ix t he d et ector h ea d to
the bo tt om c ov er a nd adjust t he d et ec to r head to b e in
the co rr ec t po si tion.
FIG.14-A
FIG.14-C
FIG.9-B
1
Corner
mounting
bracket
Patt er n
It em
Quantity
Manual
1
Rubb er
washer
Screw support
Cable entry
knock-out
Cable entry
knock-out
3.4.1 Wall mount and ceiling mount
3.4.1.1 When installing, the junction box of detector can be stuck
on the bottom cover by inserting the hook into the slot, so
that you don’t need to hold the product on hand, to make
installation conveniently (See FIG.9-A & FIG.9-B & FIG.9-C).
3.4.1.2 Please strip off 6-8mm of cables sheathing by tool before
install atio n.
3.4.1.3 Feed the electric cables through rubber gasket
(see FIG.8) and refer to illustration of FIG.5 - FIG.7 for
correct wiring, then fit the bottom cover on the wall or
ceiling firmly by two screws (See FIG.10).
The unique holiday mode for randomly switching ON / OFF
load is worked as a simple security function to protect your
property.
The IR remote control is available for quick and convenient
setting (for optional purchase).
Accessories for optional purchase
OS-240PA / OS-300PA / OS-360PA
3.2.3 Holi da y fu nct io n
FIG.15-A
Corner installation
µ
FIG.1-B
Wall corner mounting bracket
(Optional purchase):80 74.5 28mmx x
74.5mm
80mm 28mm
5
5
0
16m
7
7
O
300
OS-300PA
Top vi ew Side v ie w
FIG.4
Les s sensi tive to m oveme nt
directly towards detector
More sensitive to movement
across the detector
3.2. 2 Ma nu al over ri de f or swit ch in g lig ht o n fo r 8 ho urs
(Lux i s in de pende nt )
Under Auto mode, the load will turn on automatically when the
movement is detected and the ambient light level is below the
Lux setting value. When no movement is detected and the
delay time has expired, the load will turn off automatically.
3.2.1 Auto mode
3.2 Function
3.3.3 For HVAC control (See FIG.7)
M
Manual
Switch
A1 A2
Supply
Voltage
Fan
Heater
Contactor
Blu e Brown Red Re d
N
N
N1
L
L
L1
D1 D2
Motion detector
FIG.7
3
and ad ju st t he d et ec tor hea d to b e in t he r ig ht posi ti on
(See F IG.12-A & FIG.12-B).
.4.1.4 Fix the detector head to the bottom cover (See FIG.11)
FIG.10
6-8mm
FIG.14-B
150mm
66mm
111m m
Φ90mm
80mm
Ceiling mount:
Ceiling mount: 166 x 90 x 111mm
FIG.1-C
166mm
1
2
3
5
4
6 78
Set the Lux knob to “Holiday” position, LED will flash quickly
for 10sec, and then keep on for 10sec to indicate detector
entering into Holiday mode. Detector is uncontrolled by Lux and
Time under Holiday mode.
Under Holiday mode, the light will turn on automatically
when the ambient light level is below 50 Lux. Then the light
will randomly turn ON and OFF between 10min to 1hr for the
next 4 hr s. W he n th e lo ad is off, L ED w ill fla sh b y tu rn s. W he n
the lo ad i s on , th e 4 LE Ds w ill fla sh s im ul ta neous ly u nd er t hi s
mode .
Exit Holiday mode: During the Holiday mode, adjust the
Lux knob to other positions beside “Holiday”, load will
turn off and LED will flash for 5sec to indicate detector exiting
Holiday mode.
1-8 holes are
screw
knocku-outs
FIG.9-C
PASSIVE INFRA-RED SENSOR
FOR AUTOMATION CONTROL
OUTDOOR PIR MOTION DETECTOR
for Lighting or HVAC Automation
Control
OS-360PA OS-300PA OS- 240PA
Wall mount:
1s.
Loa d
Staircase timer
N
L
LD1 D2
N
Motion detector LN
OUT
IN
μ
3.3.2 Staircase timer switch controlled by one sensor (Time should
be set to (See FIG.6).
1S.
Blu e Brown Red Re d
FIG.6
N
L
5
5
0
16m
16m
7
7
Top vi ew Side v ie w
O
180
Φ10m
Φ14m
Φ32m
Φ10m
Φ14m
Φ32m
Φ10m
Φ14m
Φ32m
Φ10m
Φ14m
Φ32m