Thank you for choosing this quality Ektor product.
This manual is intended to help you install this
product in a way that ensures the safety of yourself
and others. Whilst this Ektor product is designed
to be installed easily, we highly recommend you
take the time to read this manual thoroughly before
commencing installation. When installed correctly
and serviced regularly, this product will provide
hassle free operation for many years.
1
Welcome
Overview
Safety warnings
Installation
Mounting
Terminal block wiring
Self-test wiring / central battery system
DALI wiring / central battery system
Using the inverter with a switch
Using the inverter with a sensor
Using the inverter with an onboard microwave sensor
Maintaining your Circular Pearl luminaire
Replacing the battery
Battery life
Power and battery charge
Wireless daughterboard
Non maintained / maintained jumper
Discharge rating selection
Onboard microwave sensor settings
Accessories list
Self-test indicator LEDs
Self-test / commissioning interval programming
Product specifications
Australian emergency classification
Spacing table
Construction sites
Testing precautions
Problem solving procedure
Warranty information
Compliance standards
Technical support and troubleshooting
MANUFACTURED
TO ISO9001
1808 EV-PEARL-EM-WP
1809 EV-PEARL-EM-PRO-WP
1810 EV-PEARL-WP
1811 EV-PEARL-PRO-WP
1812 EV-PEARL-EM-WP-S
1813 EV-PEARL-EM-PRO-WP-S
1814 EV-PEARL-WP-S
1815 EV-PEARL-PRO-WP-S

CIRCULAR PEARL EMERGENCY INSTALLATION INSTRUCTIONS
2. OVERVIEW
Ektor Generation III platform introduces you to a new era of emergency lighting control. With years in the
making, the third generation platform builds on the Ektor product ranges’ increasing quality, reliability and
performance. In choosing this Ektor product you can be comfortable that you have the best.
This product out of the box can be wired in any of these configurations:
• Self testing unit
• Standalone unit
• Standalone unit controlled with a switch or sensor
• DALI controlled remote testing unit
And can be used with a central battery system (monitored and non-monitored)
An optional wireless module can be added to allow you to connect to standard Wi-Fi networks for remote
testing and reporting.
Our Ektor Generation III platform also brings class leading technology which increases performance and
reliability including:
• Smart battery charging technology which reduces power consumption up to 90% while
increasing the service life of the battery
• Smart battery conditioning to ensure the best performance from the battery
• 450V Electrolytic capacitors which increase the products reliability
• Highly efficient design to reduce fatigue on the product
For buildings requiring longer durations such as 3, 4 and 8 hours the installer can change the jumpers found
on the unit for automatic scaling of the output.
2
3. SAFETY WARNINGS
1. THIS PRODUCT MUST ONLY BE INSTALLED BY A LICENSED ELECTRICIAN.
2. BEFORE COMMENCING INSTALLATION TURN OFF AND ISOLATE THE ELECTRICAL SUPPLY.
3. DO NOT ENERGISE WITH PRODUCT OPEN OR DISASSEMBLED.
4. SUPPLY VOLTAGES WITHIN PRODUCT. ISOLATE SUPPLY VOLTAGES BEFORE OPENING OR SERVICING.
5. THE ONLY USER SERVICEABLE PART IS THE BATTERY PACK.
6. DO NOT ATTEMPT TO SERVICE OTHER PARTS OF THE FITTING AS THIS WILL VOID THE WARRANTY.
7. AS THE INSTALLER, IT IS YOUR RESPONSIBILITY TO ENSURE YOU COMPLY TO ALL RELEVANT BUILDING AND SAFETY
CODES FOR EXAMPLE THE BCA, AS3000. REFER TO APPLICATION STANDARDS FOR THE RELEVANT RULES.
8. WHEN THE INSTALLATION IS COMPLETE, LEAVE THIS MANUAL WITH THE BUILDING’S OWNER(S) FOR FUTURE REFERENCE.

CIRCULAR PEARL EMERGENCY INSTALLATION INSTRUCTIONS
4. INSTALLATION
The Ektor Weatherproof Circular can be installed by mounting the product to the ceiling. To install the
Circular please follow the steps listed below:
1. Remove the product from the box and inspect it for any damage. If you believe the product to be
damaged or otherwise unsound, DO NOT install the product. Please pack it back into its box and return
it to the place of purchase for replacement. If the product is satisfactory, proceed with the installation.
2. When mounted the Circular cover MUST be opened. Open the cover by releasing the clasps and swing
the cover upwards by its hinge as shown below. This will allow for the gear tray to become visible.
3. Locate the screw(s) holding the gear tray in place, unscrew it and swing the gear tray upwards.
4. The cover is to be released for mounting the Circular, battery replacement and servicing.
NOTE: No tools should be
used to release the clasps
Circular cover
Circular cover
Gear tray
Clasps
Figure 1: Circular installation
3

CIRCULAR PEARL EMERGENCY INSTALLATION INSTRUCTIONS
5. MOUNTING
Before you start mounting your Circular, the access point for the terminal block wiring must be chosen.
There are three different access points(A, B, C), option C is specificaly for conduit entry.
1. Drill a hole through the Circular base in the desired position. Route the wiring for the terminal block
through the holes and the supplied weatherproof gland.
2. Move the Circular into position on the ceiling and mount by fastening the screws securely to the flat
surface with the use of the supplied washers.
3. Wire the terminal block as shown in section 6 (page 5), tighten cables into the strain relief and
reassemble cover as in steps 2 and 3.
CEILING MOUNT
Figure 2: Ceiling mount
4
6 gage screws
not supplied
Strain relief
NOTE: Optional maisonary anchors/raw plugs are supplied
A
B
C
Washers
supplied

CIRCULAR PEARL EMERGENCY INSTALLATION INSTRUCTIONS
E
E
E
E
5
6. TERMINAL BLOCK WIRING OPTIONS
The wiring for Circular differs between models and accessories installed. Wiring schematics for the terminal
blocks used with the Circulars in the following sections.
Figure 3:
Mains operation only
Figure 4:
Emergency models
EV-PEARL & EV-PEARL-PRO
EV-PEARL-EM & EV-PEAR-EM-PRO
Standard DALI emergency
External sensor
External switchExternal sensor
Unswitched activeUnswitched active
ActiveActive
Optional Optional
Optional Optional
Standard
E
Switched
EE

CIRCULAR PEARL EMERGENCY INSTALLATION INSTRUCTIONS
E
6
8. DALI WIRING/ CENTRAL BATTERY SYSTEM
The Circular inverter supports DALI out of the box, illustrated in the hardwiring diagram
shown below. The inverter also supports central battery systems and can be monitored through DALI. When
used as a central battery system the devices can be tested with DALI. See wiring diagram in section 6 (page 5).
7. SELF-TEST/ STANDARD WIRING/ CENTRAL BATTERY SYSTEM
In emergency models the inverter can be used in an automatic self-test mode which reduces the need for a test
switch timer.The self-test ability automatically disables if the unit is wired to DALI or the wireless daughterboard
is attached. Additionally the third generation platform can be wired to a central battery system. With this wiring
the system cannot report the light status (see Self test support document for more information).
NOTE: Emergency models with microwave sensors do not support central battery as regular and emergency power is not separated.
Figure 5:
Microwave models
EE
Figure 6: Emergency
microwave models
Sensor out
Optional
Sensor out
Optional
Combined input
Sensor out
Optional
Sensor out
Optional
Internal
sensor
Internal
sensor
Internal
sensor
Internal
sensor
E
EV-PEARL-S & EV-PEAR-PRO-S
EV-PEARL-EM-S & EV-PEAR-EM-PRO-S
Standard Switched
Standard DALI emergency

CIRCULAR PEARL EMERGENCY INSTALLATION INSTRUCTIONS
7
9. USING THE INVERTER WITH A SWITCH
10. USING THE INVERTER WITH AN EXTERNAL SENSOR
A mains rated switch can be wired with this product to turn ON/OFF the non-emergency light in normal use.
This does not affect operation in emergency mode. See external switch wiring diagram in section 6 (page 5).
A mains rated sensor can be wired with this product to turn ON/OFF the light in normal use. This does not
affect operation in emergency mode. See external sensor wiring diagram in section 6 (page 5).
11. USING THE INVERTER WITH AN ONBOARD MICROWAVE SENSOR
For models 1812-1815 an onboard sensor is available. In addition to switching the internal light the L’ terminal
can be used as a power supply for up tp 14 additional Circular lights.
NOTE: Emergency models with microwave sensors do not support an external switch.
NOTE: Emergency models with microwave sensors do not support an external sensor
13. REPLACING THE BATTERY
12. MAINTAINING YOUR CIRCULAR PEARL LUMINAIRE
1. Use only the LiFePO4 battery recommended on the label found on the inverter/battery charger pack.
No other battery will work in this fitting, other than the type listed.
2. Access the battery by releasing the product cover as shown in section 4 (page 3) of this manual.
3. Disconnect the battery from the product and if necessary, cut cable ties to release the battery from its
mounting position.
4. Replace the battery as was previously installed and secure with cable ties.
5. Put the Circular back into its previously mounted ceiling position and ensure the green charge light is
illuminated. Allow a few minutes for the battery to charge.
6. Allow a minimum 24 hours charging time before carrying out any discharge tests as per the requirements
in AS/NZS 2293, BCA or other relevant standards.
The Circular is connected to an unswitched active during normal operating conditions.
When disconnected from the mains supply, the Circular is powered by a LiFePO4 battery operated inverter.
Due to this, care should be taken when replacing the battery.
WARNING

CIRCULAR PEARL EMERGENCY INSTALLATION INSTRUCTIONS
8
Charge
current
Max charge current Max charge voltage Savings
Cell voltage
15. POWER AND BATTERY CHARGE
The Ektor Generation III platform uses smart battery charging technology which reduces power consumption
and increases battery life.
During the first stage of operation the battery charger charges the battery until full. Afterwards, the unit goes
into a stage which charges the battery periodically. This reduces the battery temperature and reduces the
loss of electrolytes which ultimately increases the service life of the battery.
The smart battery charger also offsets the charging time by a random interval to un-synchronise all the
emergency lighting in the building. This reduces the average loading on a building’s infrastructure and reduces
any impacts of surges created by turning on large numbers of products simultaneously.
Figure 8: Smart charge rate
14. BATTERY LIFE
The economical life of the battery installed in this unit is 4 years; it is recommended that the battery is replaced
after this time. To maintain the economical life of this product it is required that the battery be discharged
and recharged at least once every 6 months. The battery life can be reduced if the battery is not discharged
as per the requirements of AS/NZS 2293 or an equivalent standard. Increasing the number of duration tests
above that as defined in AS/NZS 2293 or an equivalent standard can have a positive effect on the battery
performance as long as 12 discharge cycles per year is not exceeded.
Figure 7: Example of included battery
1 x LiFePO4 battery (1302, 1303)
KIT INCLUDES:
1

CIRCULAR PEARL EMERGENCY INSTALLATION INSTRUCTIONS
9
17. NON MAINTAINED/ MAINTAINED JUMPER
The Emergency light in the Circular is de designer for use in no-maintained mode only.
Figure 10: Maintained/non-maintained jumper
Jumper
INDICATOR STATUS DESCRIPTION
NON MAINTAINED
MAINTAINED MODE
LED is only ON in
emergency
Not supported
18. DISCHARGE RATING SELECTION
The inverter supports a number of discharge ratings which can be selected by the user. The output from
the LED scale based on the discharge rating (see ektor.com.au for output information).
Figure 11: Discharge rating selection
Remove expansion cover
C
B
A
HOURS A B C
1 hour
2 hours (default)
3 hours
4 hours
Central battery operation
N/A
N/A
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
ON
OFF
ON
OFF
ON
ON
16. WIRELESS DAUGHTERBOARD
The Circular inverter used in emergency models also support an optional wireless daughterboard. The driver
must be disconnected from mains and battery must be removed, before installing or changing any expansion
module. More information and a list of other accessories can be found in the Wireless design and installation
guide. The assembly for this part onto the inverter is shown below:
Figure 9: Daughterboard assembly diagram
2
1
Wireless daughterboard (6118)(optional)
Circular inverter (1222, 1223, 1224, 1225)
1
2

CIRCULAR PEARL EMERGENCY INSTALLATION INSTRUCTIONS
10
The daylight threshold can be set on DIP switches, to fit for particular applications.
DAYLIGHT SENSOR
ON
OFF
Daylight: The lamp works always, even during daylight
Twilight: The lamp works only in twilight and darkness
Darkness: The lamp works only in darkness
LUX OPERATION789
2lux darkness operation only
5lux darkness operation only
20lux twilight operation
30lux twilight operation
Daylight sensor disabled (default)
I
II
III
IV
V
Figure 12: Microwave sensor
19. ONBOARD MICROWAVE SENSOR SETTINGS
Detection area can be reduced by selecting the combination on the DIP switches to fit precisely for each
specific application.
DETECTION AREA
ON
OFF
RANGE
1
2 3
100% (default)
75%
50%
30%
10%
I
II
III
IV
V
ON DIP
The time period you would like to keep the lamp on 100% after the person has left the detection area.
HOLD TIME
ON
OFF
TIME4 5 6
5 sec (walk test mode)
30 sec
180 sec
300 sec (default)
15 min
25 min
I
II
III
IV
V
VI
Ce manuel convient aux modèles suivants
7
Table des matières
Autres manuels ektor Équipement d'éclairage
Manuels Équipement d'éclairage populaires d'autres marques

Qazqa
Qazqa Suplux SL 3 Black 103062 Manuel utilisateur

Commercial Electric
Commercial Electric 54568141 Manuel utilisateur

CREE LIGHTING
CREE LIGHTING 304 Series Manuel utilisateur

Goobay
Goobay 49867 Manuel utilisateur

ECOMAN ITALIA
ECOMAN ITALIA LED T8 Manuel utilisateur

Alkalite
Alkalite Krypton KT-81 Manuel utilisateur