Eizo UX2 Manuel utilisateur

1
Instructions for Use
Calibration Sensor
Important
Please read this “Instructions for Use” carefully to familiarize yourself with safe and effective
usage.
Please retain this manual for future reference.

2
SAFETY SYMBOLS
This manual and this product use the safety symbols below. They denote critical information. Please read
them carefully.
WARNING
Failure to abide by the information in a WARNING may result in serious injury and can
be life threatening.
Indicates a prohibited action. Indicates a mandatory action.
Symbols on the unit
Direct current
No part of this manual may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means,
electronic, mechanical, or otherwise, without the prior written permission of EIZO Corporation.
EIZO Corporation is under no obligation to hold any submitted material or information condential unless prior
arrangements are made pursuant to EIZO Corporation’s receipt of said information. Although every effort has been
made to ensure that this manual provides up-to-date information, please note that EIZO monitor specications are
subject to change without notice.
EIZO, the EIZO Logo and RadiCS are registered trademarks of EIZO Corporation in Japan and other countries.
All other company and product names are trademarks or registered trademarks of their respective owners.

3
PRECAUTIONS
WARNING
If an abnormal phenomenon, such as smoke, strange noise(s), or odor(s), is detected,
immediately disconnect the product from the monitor or computer, and contact your
EIZO representative.
Attempting to use a malfunctioning unit may result in re, electric shock, or equipment damage.
Do not open the cabinet or modify the unit.
Opening the cabinet or modifying the unit may result in re, electric shock, or burn.
Refer all servicing to qualied service personnel.
Do not attempt to service this product yourself as opening or removing covers may result in re,
electric shock, or equipment damage.
Do not use the product near equipment that is vulnerable to magnetic elds.
Magnets are used in this product. If the product is used near the equipment shown below,
normal operations may be interrupted or records may be damaged due to magnetic elds.
• Precision equipment
• Magnetic storage media such as magnetic cards, prepaid cards, and tickets
• Electronic or communication equipment such as speakers, CD or DVD players, and mobile phones
Dispose of the products in accordance with the laws and regulations of your region.

4
Introduction
This product is a sensor that is used to perform calibration, Luminance checks, Grayscale checks, and other
operations using RadiCS monitor quality control software. For information on how to use RadiCS, refer to
the RadiCS User's Manual.
Package Contents
Check that all the following items are contained in the package. If any items are missing, contact your
EIZO representative.
• UX2 Sensor
(Including a magnet with a band and adsorptive
sheet)
• Protective cap*1
• Storage case
• Adsorptive sheet for the replacement
• Cleaning cloth
• Instructions for Use (this book)
• "RadiCS" quality control software*2
*1 This product is attached to the UX2 Sensor at the time of shipment.
*2 Only available when you purchase RadiCS UX2.
Compatible Monitors
This product is provided specically for the EIZO RadiForce series monitor. Usage with a monitor that is
not compatible may not be covered by the warranty.
For details on the compatible monitors, refer to our web site. http://www.eizoglobal.com/

5
Precautions for Use
• Measurement accuracy may be compromised if the product is subjected to excessive
impact, such as by being dropped, etc.
If the product has been subjected to a strong impact, we recommend that you carry out
calibration.
• Measurement accuracy may be compromised if the product is stored or used in the
following environments.
- Location subject to direct sunshine
- Location containing dust
- Location in which corrosive gases (dioxide gas, hydrogen sulde gas, nitrogen dioxide
gas, chlorine, ammonia, ozone, etc.) do or may exist
- Location in which substances (sodium chloride, sulfur, etc.) that cause corrosion exist in
dust or air
• If you place this product in a room while the product is cold, or if you raise the room
temperature abruptly, dew may form on the surface or inside the product (condensation).
Should dew form, please wait until it has disappeared before connecting the product. If
you use the product while dew is still on it, a malfunction may occur.

6
Attaching the Product
Attention
• To use the UX2 Sensor, you need to install RadiCS in advance. For details, refer to the RadiCS User's
Manual.
• Wipe any dust, water droplets, dirt, etc. off the monitor screen before attaching the UX2 Sensor.
• If the adsorptive sheet is dusty or dirty, wipe it before attaching the UX2 Sensor.
• Do not forcibly press the UX2 Sensor against the monitor. Doing so may cause a display error such as
interference patterns appearing on the monitor.
Connect the USB cable to the USB downstream port of the PC and the USB upstream port of the monitor.
1. Connect the USB connector of the UX2 Sensor to the USB downstream port of the PC or
monitor.
When the PC recognizes the UX2 Sensor, the LED indicator of the UX2 Sensor lights up blue.
2. Turn the protective cap and remove it from the UX2 Sensor.

7
3. Attach the UX2 Sensor to the measurement position on the monitor screen. (Figure 1)
The adsorptive sheet has a cover lm at the time of shipment. Before attaching the sheet, peel
the lm off. Align the four lines in front of the UX2 Sensor with the cross line displayed in the
measurement area.
4. Carefully slide the magnet, and x it to the stand attachment part of the monitor. (Figure 2)
Magnet
Figure 1 Figure 2
Note
• When you execute calibration or various tests of the monitor using the UX2 Sensor via RadiCS,
the LED indicator is turned off.

8
Adsorptive Effect of Adsorptive Sheet
If the adsorptive effect of the adsorptive sheet becomes week, slightly moisten the cleaning cloth
contained in the package with water and wipe the adsorptive sheet.
If you continue to use the adsorptive sheet while the adsorptive effect is weak, the sensor section may
fall off or measurement accuracy may be compromised.
Attention
• Make sure that the adsorptive sheet is dry before attaching it to the monitor screen.
• Make sure that no water droplets splash onto the light receiving section. Otherwise, measurement
results may be compromised.
Persistent Issue with Adsorptive Sheet
If the adsorptive effect of the adsorptive sheet remains weak, replace it with a spare one.
1. Peel off the adsorptive sheet attached to the UX2 Sensor.
2. Peel the seal off from the spare adsorptive sheet, and attach it to the UX2 Sensor.
Note
• The absorption pad can be purchased separately if necessary. Contact your EIZO representative.

9
Detaching the Product
1. Detach the UX2 Sensor from the monitor.
Carefully pull the UX2 Sensor off from the bottom.
2. Insert the protective cap into the dent of the UX2 Sensor, and turn the protective cap to x
it.
Attention
• To prevent the detector area from becoming dusty, store the product with the protective cap
attached.
3. Disconnect the USB connector of the UX2 Sensor from the USB downstream port of the
PC or monitor.
To store the product, we recommend that you bundle the cable using the band with the magnet and
put it into the storage case. Exercise care not to bundle the cable too tightly.

10
Product Care
Cleaning
Attention
• Using chemicals such as alcohol or disinfectant may lead to defects such as discoloring or color
fading.
• Never use thinner, benzene, wax, or polishing cleaner as these will damage the sensor section.
To wipe off dirt, use the cleaning cloth supplied with this product.
If you use the product while the detector area is dusty or dirty, measurement accuracy may be
compromised. Wipe off dust or dirt thoroughly.
Detector area
Maintenance
It is recommended that you calibrate the product annually in order to maintain measurement accuracy.
Table des matières
Autres manuels Eizo Accessoires

Eizo
Eizo TP1 Manuel utilisateur

Eizo
Eizo FP-503 Manuel utilisateur

Eizo
Eizo FP-2100W Manuel utilisateur

Eizo
Eizo FP-2701W Manuel utilisateur

Eizo
Eizo FP-2000W Manuel utilisateur

Eizo
Eizo FP-502 Manuel utilisateur

Eizo
Eizo EX3 Manuel utilisateur

Eizo
Eizo FP-2000 Manuel utilisateur

Eizo
Eizo EX4 Manuel utilisateur

Eizo
Eizo 2100W Manuel utilisateur