edenox VAKSIC-8 E Manuel utilisateur

SAVE THESE INSTRUCTIONS CAREFULLY
Read these instructions carefully before using your
microwave oven, and keep it carefully.
If you follow the instructions, your oven will provide you with
many years of good service.
Model:
MICRO-1834-D
CHAMBER VACUUM
PACKING MACHINE
USER’S MANUAL

INDEX
1. SUMMARY
2. USAGE
3. FEATURE
4. TECHNICAL PARAMETER
5. STRUCTURE AND PRINCIPLE
6. CONTROL PANEL INDICATION
7. INSPECTION AND ADJUSTMENT
8. OPERATION PROCESS
9. TROUBLESHOOTING
10. MAINTENANCE
11. CONTROL PANEL VIEW
12. ELECTRIC PRINCIPLE DIAGRAM
13. MACHINE EXPLODED DIAGRAM
14. ACCESSORIES

1. Summary
Single chamber vacuum packing machine with computer control panel is a novel packing machine which is to
vacuum and seal bag. The package in high degree vacuum and less remain air can avoid the bacteria to multiply,
oxygenize, mildewed. Meanwhile, it can reduce the soft product volume after vacuum packing in order to convenient
to transport and reserve.
2. Usage
The vacuum packager use compound film and pack solid, liquid and powder product such as food stuff,
medicine material, native and special product, marine product, chemical material and so on. The packaged
production can avoid to oxygenizing, mildewing, rusting, wetting, and pro-long the reserve time.
3. Feature
The machine is equipped with transparent organic grass cover; user can use whole packing process. Lower
chamber is stainless steel, reasonable structure, and strong draw vacuum and sealing, and nice appearance with
durable character. It conforms to the requirement of food hygienic standard.
These machine finishes draw vacuum and seal in one time. Adjust vacuum degree, sealing temperature, and
sealing time according to different packing material and requirement. Choose the best state to get best result.
The machine has character of advanced design, complete function, sable behavior, wide usage, strong sealing
and convenient maintenance. It is an ideal packing machine.
4. Technical Parameter
Model Number
VAKSIC-8 E
VAKSIC-10 E
VAKSIC-20 2A E
VAKSIC 20L 2A E
VAC-20E
Shell detail
(materials)
Stainless steel
Stainless steel
Stainless steel
Stainless steel
Stainless steel
Chamber
size(mm)
305×380×75
305×380×120
440×445×180
550×525×180
520×520×180
Voltage(V/Hz)
230/50
230/50
230/50
230/50
230/50
Power(W)
370
370
900
900
900
Sealing length
(mm)
260
300
400
400
500
Seal width(mm)
8
8
10
10
10
MAX Seal
Thickness(mm)
0.1-0.5
0.1-0.5
0.1-0.5
0.1-0.5
0.1-0.5
Vacuum time
range(Sec)
10-30
10-30
10-30
10-30
10-30
Package
Dimension(mm)
530*420*490
550*520*525
650*580*755
770*680*895
1040*670*750
Carton
weight(KG)
30
30
75
95
100
Pump
capacity(m³/H)
8
10
20
20
20

5. Structure and Principle
The machine composes of organic cover, vacuum chamber, machine body, electric appliance and vacuum
system. The vacuum chamber has heat-seal device and the heating element is nickel belt which installed on
heat-seal frame and insulated with vacuum chamber. Heat-seal frame touches closely on ballonet, which is in low
vacuum state before heat-sealed. When heat-seal, ballonet connects the air through solenoid valve, then ballonet
becomes big and heating element is pressed down. Press sealing part tightly and heat, the heating temperature and
time can be adjusted.
The machine power is AC 230V 50Hz, the motor for vacuum pump is AC230V. This heating system is
pressure adjustable type. Its means, the fist class of heating transformer is 220V, and second class has three shifts
(high, middle, low). Charging the power of second class can charge the sealing temperature, but the heat-seal
temperature is adjusted by button in panel.
The vacuum system composes of heat-seal electromagnetic valve YV2, release electromagnetic valve YV1.
When star the vacuum pump, vacuum chamber is drawing out the air. When reaches the preset vacuum degree, the
vacuum system stops running and next process will star, and automatic seal and release at one time.
6. Control panel indication
1) Control panel
There is vacuum meter, emergency stop key, setting key, adding key, reducing key, temperature adjusting key,
time display key and some pilot lamp.
2) Machine enters into waiting state when closed the air switch behind machine, Then set Vacuum
degree, sealing time, cooling time and sealing temperature.
a. to adjust vacuum degree: Press SET Button, the vacuum pilot lamp is on. Machine enters the setting
state of exhausting time, it shows the current exhausting time on time monitor, Meanwhile, user could
set the vacuum time according to the packing product. Press up and down key to change the vacuum
time. The longer time, and the higher vacuum degree, on the contrary, the lower degree of short
time(the range of exhausting time is between 1-99 second). Press “set” key, again after getting the
required exhausting time, and the “sealing pilot lamp” is on, and the machine enter the heat-seal time
setting state.
b. To set the sealing time, press “set” two times, the “sealing pilot lamp” is on. The machine enters the
setting state if sealing time, and it shows the current sealing time. Set sealing time according to the
thickness and material of vacuum-bag, press up and down key to increase or reduce the sealing time
(the range of sealing time is between 0.1-9.9 second). Press “set” again after setting sealing time, and
the “cooling pilot lamp” is on and then machine enters the cooling time setting state.
c. To set the cooling time: model VAKSIC-8 E / VAKSIC-10 E: press “set” key three times, the “cooling
pilot lamp” is on, and the machine enters the setting state of cooling time. It shows the current cooling
time on time monitor, and user set the cooling time according to the sealing time and sealing
temperature. Press up and down key to increase or reduce cooling time (the range of cooling time is
between 0.1-9.9 second). Press “set” key again after sealing cooling time, and show “ED” that indicate
setting is success, and machine start to run according to your setting digital. Model VAKSIC-20 2A E /
VAKSIC 20L 2A E / VAC-20E: the cooling time and heat-seal time is the same as the above.
d. To set the Sealing temperature is adjusted according to thickness and material of bag. The adjustment
of temperature have three shifts: high-middle-low. There are three pilot lamps on panel, in which have
the neutral shifts (pilot lamp is off, it indicate that there is without temperature). Press the “temperature
adjustment” key on time, the pilot lamp beats on time, continues to press it, the temperature circulate
beat among three shifts and neutral shift. As long as pilot lamp in any shift is on, it indicates the
temperature is this shift one.
e. Vacuum degree, sealing time, cooling time and sealing temperature are set by the requirement of
user.

7. Inspection and Adjustment
7.1 After opening the container, check whether accessory is completely, and the screws in all parts of the
machine are tighten and the organic glass cover move up and down freely.
7.2 Lubricate the moving parts, oil hole and oil nozzle regularly. Add rational gasoline, vacuum oil into vacuum
pump, oil level is between 1/4-3/4 of oil window.
7.3 Adjustment
7.3.1 Vacuum degree adjustment
According to the requirement of packing goods, choose the best exhausting time to obtain the appropriate
vacuum degree. The longer exhausting time, the higher vacuum degree.
7.3.2 Adjustment of heat-seal time and temperature
According to the bag material and different product, choose the best heat-seal temperature (1-3 shifts adjustable)
and heat-seal time (0.1-9.9second) one panel. Adjusting is from low to high until the best seal intensity and
appearance.
8. Operation Process
8.1 Connect to power supply, turn on the power switch, namely, the pilot lamp is on, Set exhausting time, heat-seal
time and heat-seal temperature.
8.2 Put the product into packing bag (plastic compound or aluminum foil bag) into the vacuum chamber and put
the bag top under heating seal strip orderly.
8.3 Press cover down, and the pilot lamp for vacuum in panel is on. The vacuum pump is exhausting, and the
cover is sucked automatically. Adjust vacuum time according to the packing requirement.
8.4 When the exhausting time reaches the set one (required vacuum degree), the process are finished, and the
pilot lamp is off. Now the pilot lamp for heat-seal time is on and begin to seal. There are heat-seal time and
temperature adjustment buttons on panel to adapt the different thickness material, and according to the specification
of bag.
8.5 When time reached the preset, the pilot lamp is off. It means the heating seal is finished and exhausting
electromagnetic valve works. The air enters into vacuum chamber, and the cover is lifted up. Now the packing
process is completed and turns to next process.
9. Troubleshooting
9.1 Can not vacuum and vacuum degree is low
9.1.1 Check if the vacuum pump rotates anticlockwise, and the rotating direction of vacuum pump is the same as
the arrows marked in motor.
9.1.2 When using new machine, the gasket in cover doesn’t touch the vacuum chamber well.
9.1.3 Check if the micro-switch is connected well.
9.1.4 The release electromagnetic valve isn’t closed well, check if the release electromagnetic valve and its axis
(rubber) is damaged or polluted and its axis is moving away. Please repair if replace if appears above states.
9.1.5 Check if the parts are leakage or loosed.
9.2 The heat-seal quality isn’t good.
9.2.1 Check if the bag mouth is clean.
9.2.2 Check if the heating element works regularly.
9.2.3 Check if the transformer output the voltage, if it isn’t output, please check the input circuit. If transformer has
input but without output, replace the transformer.
9.3 Main board trouble
9.3.1 Keep electric circuit of main board clean and dry. Not allow the metal on surface in order not to cause
short-circuit of main board interior, or the procedure chaotic.
9.3.2 Machine doesn’t vacuum and heat-seal, check the relative plug is connected well or button is damaged.
9.3.3 The digital board shows the trouble or without action indicates, check the plug of digital board is loose or
digital board is damaged.
9.3.4 One of heat-seal shifts is out of work, check the plug of relative relay isn’t connected well or the relay is
damaged.

10. Maintenance
10.1 Read the manual carefully before operation.
10.2 Add oil into the vacuum pump periodically.
10.3 Check if the machine is connected well with ground.
10.4 check if the Teflon tape surface is clean, smooth and strong sealing.
10.5 Turn off the power while appears trouble, or press the emergency stop.
10.6 Lift the cover up after releasing air, then turn of power and check it.
11. Control Panel
VAKSIC-8 E / VAKSIC-10 E
VACUUM PACKER
VACUUM
SEALING
COOLING
DEFLATE
TIME
S
HIGH
LOW
STOP VACUUM SEALINGVACUUM METER
WORKING PROCEDURE
VAKSIC-20 2A E / VAKSIC 20L 2A E / VAC-20E
VACUUM
SEALING
COOLING
DEFLATE
TIME
S
HIGH
MIDDLE
LOW
STOP VACUUM SEALING INCREASE DECREASE SEALING TEMPERATURE
VACUUM METER OPERATION ADJUST
VACUUM PACKER

12. Electric Principle Diagram (same for all models)
Diagrama del principio eléctrico
0 1 2 3
230V
A1 A2
A1
A2
220V
Working circuit diagram
Breaker
Heating wire
Sealing Transformer out
Sealing Transformer in
Pump
High
Low
Middle
PCB
Micro Swich
230V/Solenoid valve

13. MACHINE EXPLODED DIAGRAM
VAKSIC-8 E / VAKSIC-10 E
1
2
3
4
5
6
22
24
9
18
19
20
10
8
21
7
15
16
14 25
17
12
23
13
11
vacuum packing mahcine parts list
Number Name USE Quantity
1Cover's Platen 2
2Plexiglass cover 1
3Silicone seat 1
4Silicone 1
5Heating block 1
6Vacuum chamber 1
7Chassis 1
8Breaker 1
9Solenoid valve 1
10 Micro Switch 1
11 Vacuum pump 1
12 Sealing transformer 1
13 AC contactor 1
14 Control Panel 1
15 Vacuum Meter 1
16 Panel frame 1
17 Chassis's Bottom
plate 1
18 Gas spring bracket 2
19 Gas spring pin 2
20 Gas spring 2
21
Power line
waterproof
connector
1
22 Gland bars 1
23 Low voltage control
transformer
1
24 seatSolenoid valve
seat
1
25 Bottom side box 1

VAKSIC-20 2A E / VAKSIC 20L 2A E
1
2
3
4
5
6
18
19
8
21
20
10
9
24
22
7
16
15 14
23
11
12
13
17
Outlook and control panel
vacuum packing mahcine parts list
Number Name USE Quantity
1Cover's Platen 2
2Plexiglass cover 1
3Silicone seat 2
4Silicone 2
5Heating block 2
6Vacuum chamber 1
7Chassis 1
8Breaker 1
9Solenoid valve 1
10 Micro Switch 1
11 Vacuum pump 1
12 Sealing transformer 1
13 AC contactor 1
14 Control Panel 1
15 Vacuum Meter 1
16 Panel frame 1
17 Chassis's Bottom
plate 1
18 Gas spring bracket 2
19 Gas spring pin 2
20 Gas spring 2
21
Power line
waterproof
connector
1
22 Gland bars 1
23 Bottom side box 1
24 Solenoid valve seat 1

VAC-20E
SGQ2600-102,103 spare parts exploded View & list
14. Accessories
Description
Quantity
Vacuum packing machine
1 SET
Pump oil
1 BOTTLE
Heating wire
2 PCS
Teflon tape
2 PCS
User's manual
1 PC
Allen wrench 4mm 5mm
2 PCS
Screwdriver
2 PCS
Open-end wrench pump
1 PC
Ce manuel convient aux modèles suivants
4
Table des matières
Langues :
Autres manuels edenox Appareils de cuisine