Eden ED-7007 Manuel utilisateur

ED-7007
ED-7009
EN | Instruction manual
NL | Gebruiksaanwijzing
FR | Mode d’emploi
DE | Bedienungsanleitung
ES | Manual de usuario
PT | Manual de utilizador
IT | Manuele utente
SV | Bruksanvisning
PL | Instrukcja obsługi
CS | Návod na použití
SK | Návod na použitie

1
2
13
PARTS DESCRIPTION / ONDERDELENBESCHRIJVING / DESCRIPTION DES PIÈCES /
TEILEBESCHREIBUNG / DESCRIPCIÓN DE LAS PIEZAS / DESCRIÇÃO DOS
COMPONENTES / DESCRIZIONE DELLE PARTI / BESKRIVNING AV DELAR /
OPIS CZĘŚCI / POPIS SOUČÁSTÍ / POPIS SÚČASTÍ
5
11 10
9 12
8
4
7
6
3

Instruction manual
3
SAFETY
• Please read this user’s manual carefully to
ensure proper use, maintenance and
installation.
• By ignoring the safety instructions the
manufacturer cannot be held responsible for
the damage.
• The appliance is for indoor use only.
• Do not use the unit on a socket that is
damaged or that has not been installed
correctly.
• Do not use the unit:
– near a source of fire.
– in an area where oil is likely to splash.
– in an area exposed to direct sunlight.
– in an area where water is likely to
splash.
– near a bath, a shower or a swimming
pool.
• Never insert your fingers or objects into the
air outlet. Take special care to warn children
of these dangers.
• Keep the unit upright during transport and
storage.
• Before cleaning the unit, always turn off or
disconnect the power supply.
• Always turn off and disconnect the power
supply before moving the unit.
•WARNING: To avoid the risk of fire, do
not cover the unit.
• All the unit sockets must comply with the
local electric safety requirements. If
necessary please check.
• If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualified persons in order
to avoid a hazard.
• If the supply cord is damaged, it must be
replaced by the manufacturer, service agent
or qualified person(s) in order to avoid a
hazard.
• This appliance can be used by children aged
8 years and above, persons with reduced
physical, sensory, and mental capabilities or
persons with a lack of experience and
knowledge if they have been given correct
supervision or instruction concerning the use
of the appliance in a safe way and
understand the hazards involved. Children
should not play with the appliance. Cleaning
and user maintenance should not be carried
out by children without supervision.
EN

Instruction manual
4
• This appliance is only to be used for
household purposes and only for the
purpose it is made for.
• Notes:
– In the case of any damage, please
disconnect the power supply and contact
the dealer or a designated repair shop.
– In any case, the power cord shall be
firmly grounded.
– To avoid the possibility of danger, if the
power cord is damaged, please
disconnect the power supply. It must be
replaced by the dealer or a designated
repair shop.
Warning
• Please use the recommended defrosting and
cleaning process from the manufacturer
only. Do not accelerate the defrosting or
cleaning process in any other way.
• The appliance shall be stored in a room
without continuously operating ignition
sources (for example: open flames , an
operating gas appliance or an operating
electric heater).
• Do not pierce or burn.
• Be aware that refrigerants may not contain
an odor.
• The appliance should be installed, operated
and stored in a room with a floor area larger
than X m2. (X=4 for 5000Btu/h, 7000Btu/h,
8000Btu/h; X=7.7 for 9000Btu/h. 10000Btu/
h, 10500Btu/h)
• Only contact an authorized service
technician for repair or maintenance of this
unit.
• Do not pull , deform or modify the power
supply cord or immerse in water . Pulling or
misuse of the power supply cord could result
in damage to the unit and cause an electrical
shock.
• Compliance with national gas regulations
should be observed.
• Keep ventilation openings clear of
obstructions.
• Any person who is involved with working on
or opening a refrigerant circuit should hold a
current valid certificate from an industry
accredited assessment authority which
authorizes their competence to handle
refrigerants safely in accordance with an
industry recognized assessment
specification.

Instruction manual
5
• Servicing should only be performed as
recommended by the equipment
manufacturer. Maintenance and repair
requiring the assistance of other skilled
personnel should be carried out under the
supervision of a person(s) competent in the
use of flammable refrigerants.
• Do not stop the unit by pulling out the power
plug whilst in operation as this may cause
an electric shock or fire due to heat
generation unless strange sounds are heard
or if strange smells or smoke appear from
the unit.
Specific information regarding appliances with R 290 refrigerant gas.
• Thoroughly read all of the warnings.
• When defrosting and cleaning the
appliance , do not use any tools other than
those recommended by the manufacturing
company.
• The appliance should not be stored in a
room with continuously operating ignition
sources (for example: open flames , an
operating gas appliance or an operating
electric heater).
• Do not puncture and do not burn.
• Appliance shall be installed, operated and
stored in a room with a floor area larger than
X m2. (X=4 for 5000Btu/h, 7000Btu/h,
8000Btu/h; X=7.7 for 9000Btu/h. 10000Btu/
h, 10500Btu/h)
• This appliance contains Y g (see rating label
back of unit ) of R290 refrigerant gas.
• R290 is a refrigerant gas that complies with
the European directives on the environment.
Do not puncture any part of the refrigerant
circuit.
• If the appliance is installed, operated or
stored in a non-ventilated area, the room
must be designed to prevent to the
accumulation of refrigerant leaks that could
result in a fire risk or explosion due to
ignition of the refrigerant caused by electric
heaters, stoves, or other sources of ignition.
• The appliance must be stored in such a way
as to prevent mechanical failure.
EN

Instruction manual
6
• Individuals who operate or work on the
refrigerant circuit must have the appropriate
certification issued by an accredited
organization that ensures competence in
handling refrigerants according to a specific
evaluation recognized by associations in the
industry.
• Repairs must be performed based on the
recommendation from the manufacturing
company. Maintenance and repairs that
require the assistance of other qualified
personnel must be performed under the
supervision of an individual specified in the
use of flammable refrigerants.
Batteries
• Do not expose the battery to high
temperatures or direct sunlight. Never throw
batteries into the fire. There is a danger of
explosion!
• Keep batteries away from children. Batteries
are not a toy!
• Do not open the batteries by force.
• Avoid contact with metallic objects.(Rings,
nails, screws et cetera) there is a danger of
short-circuiting!
• As a result of a short-circuit batteries may
heat up consider-ably or even catch fire. this
may result in burns.
• For your safety the battery poles should be
covered with adhesive strips during
transport.
• Do not touch a ruptured and/or leaking
battery. If the liquid from the battery gets into
your eyes, rinse your eyes as soon as
possible with clean water, without rubbing
your eyes. Immediately go to the hospital. If
it is not treated properly, it can cause eye
problems.
Refrigerant
(CE) N 842/2006: This unit contains the refrigerant R290. The amount
of refrigerant is less than 1kg, and is in a closed cooling circuit. The
coolant does have zero ozone depletion potential, but is a so-called
greenhouse gases under the Kyoto Protocol and may thus contribute
to global warming, if it is released to the atmosphere. Therefore only
trained technicians with refrigerant certificate make a filling or
emptying. Your appliance does not have be refilled with refrigerant if
used properly and has an undamaged coolant circuit. GWP: R290: 3

Instruction manual
7
PARTS DESCRIPTION
1. Air inlet 8. Hose connector (window end)
2. Air filter 9. Hot-air exhaust hose
3. Control panel 10. Hose connector (Air conditioner end)
4. Power cord 11. Windows slider kit + fixing plugs
5. Air outlet 12. Remote control
6. Castor 13. Batteries
7. Drainage hole
FUNCTION OF CONTROL PANEL
1. Power (on/off) button
2. Temperature buttons
3. Mode button
4. Fan speed adjustment button
5. Timer (on/off) button
REMOTE CONTROL
1. Temperature up button
2. Mode button
3. Fan speed adjustment button
4. Timer (on/off) button
5. Temperature down button
6. Power (on/off) button
EN

Instruction manual
8
BEFORE THE FIRST USE
Before starting operations in this section:
• Find a place where there is power supply nearby.
• Install the exhaust hose and adjust the window position well.
• The supplied small white clips must be mounted on the window
kit.
• Insert the power cord into a grounded AC220-240V~/50Hz
socket.
• Press the power button to turn on the air-conditioner.
• Set the temperature range: 16°C-31°C.
• Check whether the exhaust hose has been mounted properly.
• When using functions on cooling and dehumidifying, allow at least
3 minutes between powering off and powering on.
USE
Cooling operation
• Press the “Mode“ button till the “Cool“ icon appears.
• Press the or button to select a desired room
temperature.
• Allow around 5 minutes for the cooling to start.
• Press the “fan speed” button to adjust airflow.
Dehumidifying operation
• Press the “Mode“ button until the “dehumidify indicator lamp“
blinks.
• The temperature will automatically be selected.
• The fan speed will automatically be selected.
Timer operation
Timer ON setting
• When the air-conditioner is OFF, press the “Timer“ button and
select a desired ON time and adjust using the temperature
buttons.
• The ON time can be adjusted to anytime in 0-24 hours.
Timer OFF setting
• When the air-conditioner ON, press “Timer“ button and select a
desired OFF time through the temperature buttons.
• The OFF time can be adjusted to anytime in 0-24 hours.
Drainage
• After a lengthy operation and before storage, you will need to
drain the water that has been collected. Please prepare a suitable
location or tray to collect the water and remove the rubber stop

Instruction manual
9
from the drainage hole at the bottom of the unit. The water will
then begin to drain. After this has stopped, you can insert the
drain stop.
Internal Tank Water Full Alarm Function
• The inner water tank in the air-conditioner has one water level
safety switch that controls the water level. When the water level
reaches an anticipated height, the water full indicator lamp lights
up. Follow above steps to drain the water.
INSTALLATION
• The air-conditioner should be installed on a flat and stable
surface. Do not block the air outlet and allow at least 30cm
around the unit.
• Socket wiring should be in accordance with the local electric
safety requirements.
Exhaust Hose Installation
• Twist both ends of the hot-air exhaust hose into the hose
connector window end and the hose connector air conditioner
end.
• Insert the hose connector air conditioned end into the openings at
the back of the air conditioner.
• Fix the hose connector window end to the nearest windowsill.
EN

Instruction manual
10
Window Slider Kit Installation
• Adjust the width (picture 1) or height (picture 2) of the windows
slider(11) to fit the window opening and fixate the position of the
windows slider(11) with the fixing plugs.
• Slide the window up to the slider.
CLEANING MAINTENANCE
• Before cleaning, disconnect the unit from any electric supply
outlet.
• First clean the surface with a neutral detergent and wet cloth, and
then wipe it with a dry cloth.
• Do not use gasoline or other chemicals to clean the unit.
• Do not wash the unit directly.
Air filter
• The air filter should be cleaned once every two weeks.
• Open the air inlet grille and take off air filter.
• Clean the air filter with neutral detergent in lukewarm 40°C water
and allow to dry (not in direct sunlight).
• Re-install the air filter into the inlet grille.
TROUBLESHOOTING
Troubles Possible Causes Suggested Remedies
The unit
does not
start
when
pressing
power
button.
• Water full indicator
lamp blinks and water
tank is full.
• Room temperature is
higher than the setting
temperature.(Electric
heating mode)
• Room temperature is
lower that the setting
temperature.(Cooling
mode)
• Drain the water out of the
water tank.
• Adjust the temperature.
Ce manuel convient aux modèles suivants
1
Table des matières
Langues :
Autres manuels Eden Climatiseur