Ecler VEO-XTI1C Manuel utilisateur

v.20190301
VEO-XTI1C / VEO-XRI1C
VIDEO DISTRIBUTION OVER IP
H.264 Full HD over IP Video Extenders
USER MANUAL

2
INDEX
1. IMPORTANT REMARK ..........................................................................................................4
2. IMPORTANT SAFETY INSTRUCTIONS ............................................................................. 4
3. IMPORTANT NOTE ................................................................................................................6
4. INTRODUCTION .....................................................................................................................6
5. PACKAGE CONTENTS ..........................................................................................................7
6. PANEL DESCRIPTION ...........................................................................................................8
6.1. Transmitter Front and Rear Panel......................................................................................... 8
6.2. Receiver Front and Rear Panel............................................................................................... 9
6.3. IR Sensor and IR Blaster connection..................................................................................10
7. INSTALLATION AND CONFIGURATION.........................................................................10
7.1. IP Address Settings.................................................................................................................10
7.1.1. Static IP Address Configuration...................................................................................10
7.1.2 DHCP (Dynamic Host Configuration Protocol) ........................................................11
7.1.3. Network Requirements...................................................................................................11
7.2. Point-to-Point Connection and Operation: ......................................................................11
7.3. Point-to-Multipoint Connection and Operation..............................................................12
7.4. Multipoint-to-Multipoint Connection and Operation.....................................................13

3
8. GROUP ID SELECTION........................................................................................................14
8.1 Group ID and RS-232 baud rate selection using IR Remote Control .......................14
8.1.1. Group ID ..............................................................................................................................14
8.1.2. Baud Rate............................................................................................................................15
8.1.3. Special Functions..............................................................................................................15
8.2. Group ID and RS-232 baud rate Selection using Web Browser ..............................15
Transmitter ID Group...................................................................................................................15
Receiver ID Group.........................................................................................................................16
Transmitter and Receiver RS-232 baud rate.......................................................................16
8.3. Group ID Selection using Telnet..........................................................................................16
9. PC UTILITY SOFTWARE.....................................................................................................17
10. HOW TO RECEIVE STREAMING WITH VLC..................................................................19
11. FACTORY RESET..................................................................................................................21
12. TECHNICAL SPECIFICATIONS..........................................................................................22

4
1. IMPORTANT REMARK
The lightning flash with arrowhead symbol, within an equilateral triangle, is
intended to alert the user to the presence of uninsulated “dangerous voltage”
within the product’s enclosure that may be of sufficient magnitude to
constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the
user to the presence of important operating and maintenance (servicing)
instructions in the literature accompanying the appliance.
WARNING (If applicable): The terminals marked with symbol of “ ” may be of
sufficient magnitude to constitute a risk of electric shock. The external wiring connected
to the terminals requires installation by an instructed person or the use of ready-made
leads or cords.
WARNING:To prevent fire or shock hazard, do not expose this equipment to rain or
moisture.
WARNING:An apparatus with Class I construction shall be connected to the main
socket-outlet with a protective earthing connection.
2. IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions.

5
8. Do not install near any heat sources such as radiators, heat registers, stoves, or
other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding type plug. A
polarized plug has two blades with one wider than the other. A grounding type
plug has two blades and a third grounding prong. The wide blade or the third
prong are provided for your safety. If the provided plug does not fit into your
outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at the
plugs, convenience receptacles, and at the point where they exit from the
apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Unplug the apparatus during lightening sorts or when unused for long periods of
time.
13. Refer all servicing to qualified personnel. Servicing is required when the
apparatus has been damaged in any way, such as power supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or
has been dropped.
14. Disconnecting from mains: Switching off the POWER switch all the functions
and light indicators of the amplifier will be stopped, but fully disconnecting the
device from mains is done unplugging the power cord from the mains input
socket. For this reason, it always shall remain readily operable.
15. Equipment is connected to a socket-outlet with earthing connection by means of
a power cord.
16. The marking information is located at the bottom of apparatus.
17. The apparatus shall not be exposed to dripping or splashing and that no objects
filled with liquids, such as vases, shall be placed on apparatus.
NOTE: This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
WARNING:This product must not be discarded, under any circumstance, as
unsorted urban waste. Take to the nearest electrical and electronic waste
treatment centre.
NEEC AUDIO BARCELONA, S.L. accepts no liability for any damage that may be
caused to people, animal or objects due to failure to comply with the warnings above.

6
3. IMPORTANT NOTE
Thank you for choosing our VEO-XTI1C & VEO-XRI1C H.264 Full HD over IP Video
Extenders. It is very important to carefully read this manual and to fully understand its
contents before making any connection in order to maximize your use and get the best
performance from this equipment.
To ensure optimal operation of this device, we strongly recommend that its maintenance
be carried out by our authorised Technical Services.
The VEO-XTI1C & VEO-XRI1C kit comes with a 3-year warranty.
4. INTRODUCTION
VEO-XTI1C encoder and VEO-XRI1C decoder are H.264 over IP extenders that allow
HDMI video distribution via local Ethernet network. This represents a very flexible,
expandable and cost-effective video distribution solution without the need of a
dedicated video cabling system. Encoder and decoder support 120m over single
Cat5e/6 cable in a point-to-point topology, or standard 100m Ethernet connection in
point-to-multipoint and multipoint-to-multipoint over standard Ethernet switch. The
over IP solutions are widely suitable for various applications such as meeting rooms,
classrooms, commercial and residential AV systems, Digital Signage systems, medical
information systems, transportation and mall advertisement.
Features:
Supports point-to-point, point-to-multipoint and multipoint-to-multipoint
configuration
Up to 120m over single Cat5e/6 cable in point-to-point connection, with 1x
looping HDMI output for daisy chaining
TCP/IP protocol compliant with selectable streaming bit rate up to 15Mbps per
stream
H.264 compression encoding that supports resolution up to 1080p@60hz.
HDCP Compliant
IR Remote control, with LED display to show Group ID. Fully operating just out of
the box without need of PC connection
Integrated web server for configuration, PC tool control and Telnet control.
Supports LPCM audio format
Wide-band IR pass-through for source control (38khz to 56khz)

7
2-way UART/RS-232 pass-through, with remote control function to select Baud
rate
Dual power input: 802.3af compliant POE & DC 5V (No need of external power
supply when encoders and decoders are connected to a POE Switch)
Included DC 5V/1A international power supply
5. PACKAGE CONTENTS
VEO-XTI1C Package
1 x H.264 Transmitter
1 x IR Remote control
1 x Local IR Receiver Cable
1 x IR Blaster Cable
2 x Mounting Ears
4 x Screws
1 x Phoenix plug for RS-232 cable termination
1 x 5V/1A International Power Supply
1 x User Manual
VEO-XRI1C Package
1 x H.264 Receiver
1 x IR Remote control
1 x Local IR Receiver Cable
1 x IR Receiver Cable
2 x Mounting Ears
4 x Screws
1 x Phoenix plug for RS-232 cable termination
1 x 5V/1A International Power Supply

8
6. PANEL DESCRIPTION
6.1. Transmitter Front and Rear Panel
1. DC 5V Power Connector
2. Data Status LED Indicator
3. Power Supply LED Indicator
4. HDMI local loop Output port
5. HDMI Input Port
6. RJ45 Ethernet Port
7. IR Blaster Port
8. Bi-directional RS-232 port
9. Local IR Receiver Port
10. Group ID channel Display
11. Group ID decrement button
12. Group ID increment button
13. Factory reset button

9
6.2. Receiver Front and Rear Panel
1. DC 5V Power Connector
2. Data Status LED Indicator
3. Power Supply LED Indicator
4. HDMI Output port
5. RJ45 Ethernet Port
6. IR Receiver Port
7. Bi-directional RS-232 port
8. Local IR Receiver Port
9. Group ID number LED Display
10. Group ID number decrement button
11. Group ID number increment button
12. Factory reset button

10
6.3. IR Sensor and IR Blaster
7. INSTALLATION AND CONFIGURATION
When VEO-XTI1C and VEO-XRI1C are connected as simple extension in a point-to-
point connection through a single Cat5e/6 cable, no configuration is needed. When
devices are connected to a standard Ethernet LAN in point-to-multipoint or multipoint-
to-multipoint topologies, please make sure that every device has unique IP address and
every transmitter is using a unique Group ID.
7.1. IP Address Settings
7.1.1. Static IP Address Configuration
When static IP addresses are required, the IP address of each device needs to be set
manually. The default IP address for transmitters and receivers is:
VEO-XTI1C: 192.168.1.11
VEO-XRI1C: 192.168.1.12
The IP address can be changed using the embedded web page or using the utility
software. For web page access, be sure that PC and VEO devices are in the same
Network Domain and just type the default IP address in your internet browser. The
default credentials for login are:
User name: admin
Password: admin
After changing default Ethernet settings press the related “Update” button and Reboot
the unit.
Autres manuels pour VEO-XTI1C
1
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Ecler Extenseur

Ecler
Ecler VEO-XPS43 Manuel utilisateur

Ecler
Ecler VEO-XRI1C Manuel utilisateur

Ecler
Ecler VEO-XTI1C Manuel utilisateur

Ecler
Ecler VEO-XPS15 Manuel utilisateur

Ecler
Ecler VEO-XTI2L Manuel utilisateur

Ecler
Ecler VEO-XTI2L Manuel d'utilisation et d'entretien

Ecler
Ecler VEO-XTI2L Manuel utilisateur

Ecler
Ecler VEO-XPT24 Manuel utilisateur

Ecler
Ecler VEO-XTI1CG2 Manuel utilisateur

Ecler
Ecler VEO-XPT44 Manuel utilisateur