Easymax R2N Manuel utilisateur

AX
EASY ®
M
SELF-MONITORING
BLOOD GLUCOSE SYSTEM
USER’S MANUAL
R2N

R2N Self-Monitoring Blood Glucose System
User’s Manual
Please read this User’s Manual thoroughly
before using your blood glucose meter.

Dear EasyMax®R2N SMBG System Owner,
Thank you for using the EasyMax®R2N Self-Monitoring Blood Glucose (SMBG) System.
We designed this system to be dependable, easy-to-use, compact, lightweight and portable to
help you monitor your blood glucose on a regular basis.
Please read this manual thoroughly before you begin testing. This manual provides you and
your diabetes care team with important information and step-by-step direction to use the
EasyMax®Self-Monitoring Blood Glucose System. To start testing quickly, you can also refer to
the Quick Reference Guide.
Thanks again for choosing the EasyMax®R2N SMBG.
Intended Use
The EasyMax®R2N Self Monitoring Blood Glucose Test System is intended for the
quantitative measurement of glucose in venous whole blood or fresh capillary whole blood from
fingertip. Testing is done outside the body (In Vitro diagnostic use). It is indicated for use at
home (over the counter [OTC]) by persons with diabetes, or in clinical settings by healthcare
professionals, as an aid to monitor the effectiveness of diabetes control.

Standard Accessories
Your new EasyMax®R2N Blood Glucose meter and accessories work together to measure
the amount of glucose in your blood. The system includes:
Optional Accessories
EasyMax
®
Control Solutions are available. For purchase, please contact
your local dealer.
• Kit Box
• User’s Manual
• Quick Reference Guide
• Test Strip Instructions
• Warranty Card
• CR2032 Battery x 2
• Carrying Case
• Blood Glucose Meter
• Test Strip x 10 ct.
• Lancet x 10 ct.
• Lancing device
• EasyMax
®
Low Control Solution
• EasyMax®Normal Control Solution
• EasyMax®High Control Solution

Why is it so important to test blood glucose regularly?
Testing your blood glucose regularly can make a big difference in how you manage your
diabetes every day. We’ve made this SMBG system as simple as possible to help you to use
the meter regularly. Your meter is easy to use, and you can adjust the lancing device for your
comfort.
Do you need Help?
If you have questions or need assistance, please contact your healthcare professional or visit
EasyMax®Website www.easymax.us for diabetes management tools and product
demonstrations.
Please complete your warranty card and mail it, so you receive the best customer service
possible and news about product update.
Although the EasyMax
®
R2N SMBG System is easy to use, you may need to consult
with your healthcare professional (this may be your doctor, pharmacist or diabetes
nurse educator) for instructions on how to use the system. Only the correct use of
the system will ensure accurate results.

Important Information about Your New EasyMax®R2N
EasyMax®R2N blood glucose meter is designed and approved for testing fresh capillary
whole blood samples from your fingertip. The meter is for in vitro diagnostic use ONLY (for
testing outside the body). It should not be used to diagnose diabetes.
EasyMax®R2N blood glucose meter can only be used with EasyMax®Blood Glucose
Test Strips. Other test strips will give inaccurate results.
Testing is not valid for neonatal blood specimens.
Do not disassemble the meter as this may cause damage to the components resulting in
incorrect readings. Disassembling the meter will also void the warranty.
Always keep the meter clean and store it in a safe place. Protect the meter from direct
sunlight to ensure a longer lifespan.
You should not store the meter and test strips in a car, bathroom, or refrigerator.
Keep the meter, test strips and lancing device away from children and pets.
You should not test critically ill patients with home-use blood glucose meters.
Incorrect results may occur when performing the test. If you believe you are not feeling
well, please contact your healthcare professional.
Remove batteries if the meter will not be used for one month or more.

Warning for potential biohazard: Healthcare professionals using this system on multiple
patients should be aware that all products or objects that come in contact with human
blood, even after cleaning, should be handled as if capable of transmitting a viral disease.
Consult with your healthcare professional before testing on your forearm or palm.
Do not touch the strips with wet hands.
Do not use expired strips (the expiration date is shown on the bottle.)
Do not bend, cut or twist the strips.
Up to the altitude of 3,048 meters has effect on readings.

Health-Related Information
If you are experiencing dehydration, frequent urination, low blood pressure, shock or
hyperosmolar hyperglycemic nonketotic coma (HHNKC), you may get a test result that is
lower than what your blood glucose really is. If you think you are dehydrated, call your
doctor right away.
If you have followed the steps in the user’s manual, but still have symptoms that don’t
seem to match your test results, or if you have questions, please talk to your doctor or
health care professional.
Please read your test strip instruction carefully for additional health-related information.
Warning for potential biohazard:
Healthcare professionals using this system on multiple patients should handle all
products or objects in contact with human blood carefully to avoid transmitting viral
disease, even after cleaning.

Explanation of Symbols
Consult instructions for use Caution
Batch code Do not re-use
In vitro diagnostic medical
device 3V (CR2032) x 1 battery only
Use by Temperature limitation
Manufacturer Catalogue number
SN/ Serial number Control
<n> Sufficient for Authorized representative in
the European Community
This product meets the requirements of Directive 98/79/EC in vitro
diagnostic medical devices

Table of Content
Chapter 1: Understanding Your Meter ….......................................................................11
The EasyMax®R2N Blood Glucose Meter …………………………….................................11
Setting the Time and Date – First Time Use .......................................................................13
Setting Hypo and Hyper .................................................................................................14
Using EasyMax®Blood Glucose Test Strips .................................................................15
Chapter 2: Control Solution Test ..........................................................................................16
Why Run a Control Solution Test ........................................................................................16
About the Control Solutions ................................................................................................17
Running a Control Solution Test .........................................................................................18
Understanding Control Test Results …...........................................................................20
Chapter 3: Testing Your Blood Glucose ...........................................................................22
Using the Lancing Device ................................................................................................22
Inserting a Lancet into the Lancing Device .........................................................................23
Running a Blood Glucose Test with Blood from Your Fingertip ..........................................25
Alternate Site Testing (Optional) ........................................................................27
Running a Blood Glucose Test with Blood from Your Forearm (Optional) ..........................29
Running a Blood Glucose Test with Blood from Your Palm (Optional) ...............................30
Discarding Used Lancets …............................................................................................31
Understanding Your Test Results..................................................................................32
Table des matières
Autres manuels Easymax lecteur de glycémie
Manuels lecteur de glycémie populaires d'autres marques

ReliOn
ReliOn Prime Manuel de l'opérateur

AgaMatrix
AgaMatrix Presto Manuel utilisateur

Polymer Technology Systems
Polymer Technology Systems A1C Now Self Check Manuel utilisateur

Medisana
Medisana GlucoDock Manuel utilisateur

Arkray
Arkray ASSURE PLATINUM Manuel utilisateur

Dexcom
Dexcom G4 Professional Manuel utilisateur

LabStyle
LabStyle Dario Manuel utilisateur

ACONLABS
ACONLABS ON CALL EXPRESS Manuel utilisateur

Higi Technology
Higi Technology iGlucose Manuel utilisateur

Bayer HealthCare
Bayer HealthCare CONTOUR NEXT Manuel utilisateur

Accu-Chek
Accu-Chek ADVANTAGE Manuel utilisateur

Sanofi-aventis
Sanofi-aventis BG STAR Caractéristiques techniques