Specifications
The following table outlines the electrical and mechanical specifications of the
Plasmasonic DRSSTC Musical Tesla Coil.
Specification
Value
Input Voltage Range
100VAC to 120VAC
(See note 1)
Max. Input Voltage
120VAC
(See note 1)
Line Frequency Range
50
-
60Hz
Dimensions
15” x 15” x 36”
Toroid Dimensions
18” DI
A x 4.5” Height
Weight
45 LBS
Max. Input Current
(
Pulse Mode
)
TBD
Max. Input Power
(
Pulse Mode
)
TBD
Inrush Current
(Start
-
up)
TBD
DC Capacitor Discharge Time
(Active discharge circuit)
5s (discharge to 30V)
8s (discharge to 5V)
DC Capacitor Discharge Time
(Passive discharge circuit)
3.5 min (discharge to 30V)
5.0 min (discharge to 5V)
Note 1: Higher input voltages are possible with user modifications, however higher input voltages do require a change in the Power
Distribution control transformer and possibly a separate AC feed for the AC cooling fans. Also, these types of user modifications void
all warranty and technical support.
Replacement Fuse Specifications
The following table lists all the replacement fuse sizes for the Plasmasonic DRSSTC
system. All fuses are located on the Power Distribution board assembly.
Fuse
Type
Control Power
–
F1
1A, Fast Acting, 1 ¼” x ¼”, Glass
Fan Power
–
F2
2A, Fast Acting, 1 ¼” x ¼”, Glass
DC Bus Power
–
F3
20A, Fast Acting, 1 ¼” x ¼”, Glass

Plasmasonic®DRSSTC Instruction Manual
December 2019, REV - − 3 − http://www.EasternVoltageResearch.com
Plasmasonic®1.3 DRSSTC Instruction Manual
WARRA TY / TAMPER I FORMATIO
PLEASE OTE THAT A Y WARRA TY PROVIDED BY EASTER
VOLTAGE RESEARCH IS PROVIDED U DER THE CO DITIO S THAT
THE EQUIPME T SOLD IS OPERATED U DER THE PRE-PROGRAMMED
OPERATIO AL CO DITIO S AS SHIPPED. THE REMOVAL OF A Y
TAMPER PROOF DECALS, O BOTH THE PLASMASO IC HA DHELD
MIDI CO TROLLER A D/OR PLASMASO IC ADVA CED CO TROLLER
MODULE, OR A Y MODIFICATIO OF A Y COMPO E T WITH THE
PLASMASO IC DRSSTC SYSTEM WILL VOID ALL WARRA TIES.
TECH ICAL SUPPORT MAY ALSO BE REFUSED IF MODIFICATIO S OR
CUSTOMER REPAIRS ARE MADE A D THAT THE TAMPER PROOF
DECALS ARE REMOVED OR ALTERED I A Y WAY FROM THE
ASSEMBLIES THEY ARE AFFIXED TO.

Plasmasonic®DRSSTC Instruction Manual
December 2019, REV - − 4 − http://www.EasternVoltageResearch.com
Plasmasonic®1.3 DRSSTC Instruction Manual
WARRA TY I FORMATIO
Plasmasonic Systems – Limited Warranty Statement
Eastern Voltage Research will repair or replace any failed component or assembly , with the listed exceptions below, that Eastern
Voltage Research has determined to be a result of a manufacturer defect.
To ensure a reliable product, all Plasmasonic systems are thoroughly tested, including a minimum 1 hour burn-in test. Customers can
be assured that they will receive a product that has been rigorously tested with the probability that all latent manufacturer defects have
been tested out through high power burn-in testing.
What is covered:
Any component that has been proven by Eastern Voltage Research to be the result of a manufacturer defect with the exceptions below.
Eastern Voltage Research will review each component failure to determine if it is covered.
What is not covered:
Because these are high power commercial Tesla Coil devices, and that we cannot control the manner and method in which a customer
uses them, the following components are not covered:
•IGBT Modules
•DC Bus Capacitors
•Rectifier Modules
•Secondary Coil
•Fiber Optic connectors and cables
User Modification / User Repair
Any user modification or user repair will void any warranty offered.
US Shipping and Warranty Repair Service
Customers are responsible for all shipping costs for returning failed components back to us for evaluation and in the determination of
warranty service. If a component failure has been determined to be a result of a manufacturer defect, Eastern Voltage Research will
cover return shipping costs for individual components or small assemblies. If service requires a full Plasmasonic assembly to be
shipped, the customer is responsible for all shipping charges to and from our facility.
International Shipping and International Warranty Repair Service
International customers are responsible for all shipping costs, including export fees, taxes, and duties, for any warranty or repair
services.

Plasmasonic®DRSSTC Instruction Manual
December 2019, REV - − 5 − http://www.EasternVoltageResearch.com
Plasmasonic®1.3 DRSSTC Instruction Manual
AGE DISCLAIMER
THIS KIT IS A ADVA CED, HIGH POWER SOLID STATE POWER
DEVICE. IT IS I TE DED FOR USE FOR I DIVIDUALS OVER 18 YEARS
OF AGE WITH THE PROPER K OWLEDGE A D EXPERIE CE, AS WELL
AS FAMILIARITY WITH LI E VOLTAGE POWER CIRCUITS.
BY PURCHASI G, BUILDI G, USI G, OR OPERATI G THE
PLASMASO IC DRSSTC SYSTEM, YOU ACK OWLEDGE THAT YOU ARE
OVER 18 YEARS OF AGE, A D THAT YOU HAVE THOROUGHLY READ
THROUGH THE SAFETY I FORMATIO PRESE TED I THIS MA UAL.
THIS PRODUCT SHALL OT BE USED AT A Y TIME BY I DIVIDUALS
U DER 18 YEARS OF AGE OR BY A YO E U FAMILIAR WITH THE
SAFETY ASPECTS OF THIS DEVICE.

Plasmasonic®DRSSTC Instruction Manual
December 2019, REV - − 6 − http://www.EasternVoltageResearch.com
Plasmasonic®1.3 DRSSTC Instruction Manual
EMI CO SIDERATIO S
IT IS THE RESPO SIBILITY OF THE E D USER / CUSTOMER TO COMPLY
WITH ALL FCC OR RELATED EMI / EMC REGULATIO S A D TO E SURE
THAT PROPER FILTERI G A D SHIELDI G IS UTILIZED TO PREVE T
A D / OR MI IMIZE THE EFFECT THE PLASMASO IC DRSSTC SYSTEM
HAS O OTHER ELECTRO IC, I CLUDI G COMPUTER, EQUIPME T I
THE VICI ITY OF OPERATIO .
EASTER VOLTAGE RESEARCH IS OT RESPO SIBLE FOR A Y
DAMAGE THE PLASMASO IC DRSSTC SYSTEM MAY CAUSE TO OTHER
ELECTRO IC A D SIMILAR EQUIPME T A D MAKES O CLAIMS
REGARDI G THE COMPATABILITY OF SUCH EQUIPME T WHE
OPERATI G I THE GE ERAL VICI ITY OF THE PLASMASO IC
DRSSTC SYSTEM OR WHE SHARI G THE SAME ELECTRICAL CIRCUIT
AS OTHER ELECTRO IC EQUIPME T.
EASTER VOLTAGE RESEARCH DOES HAVE EMI / EMC EXPERTS
AVAILABLE IF YOU HAVE A PARTICULAR ISSUE OR CO CER . FOR
MORE I FORMATIO A D / OR QUOTE OF THESE SERVICES, PLEASE
CO TACT US THROUGH OUR SALES DEPARTME T.

Plasmasonic®DRSSTC Instruction Manual
December 2019, REV - − 7 − http://www.EasternVoltageResearch.com
Plasmasonic®1.3 DRSSTC Instruction Manual
SAFETY A D EQUIPME T HAZARDS
PLEASE BE SURE TO READ A D U DERSTA D ALL SAFETY A D
EQUIPME T RELATED HAZARDS A D WAR I GS BEFORE
ASSEMBLI G A D OPERATI G THE PLASMASO IC DRSSTC SYSTEM.

Plasmasonic®DRSSTC Instruction Manual
December 2019, REV - − 8 − http://www.EasternVoltageResearch.com
Plasmasonic®1.3 DRSSTC Instruction Manual
PACEMAKER WAR I G
THIS DEVICE WHE OPERATI G WILL PRODUCE ELECTRICAL A D
MAG ETIC FIELDS. EXPOSURE TO THESE FIELDS SHOULD BE
LIMITED. DO OT USE THIS KIT IF YOU HAVE A IMPLA TED
PACEMAKER OR OTHER BIOMEDICAL DEVICE OR A Y IMPLA TED
METALLIC MATERIALS.

Plasmasonic®DRSSTC Instruction Manual
December 2019, REV - − 9 − http://www.EasternVoltageResearch.com
Plasmasonic®1.3 DRSSTC Instruction Manual
ELECTRICAL HAZARD
This circuit utilizes dangerous line voltages up to 115VAC and a
340VDC DC power bus. Failure to handle this circuit in a safe manner
may result in serious injury or death!
POWER SEMICO DUCTOR HAZARD
This is a solid state power device. Components may fail explosively
at any time and eject high velocity projectiles.
EYE PROTECTIO IS REQUIRED AT ALL TIMES!

Plasmasonic®DRSSTC Instruction Manual
December 2019, REV - − 10 − http://www.EasternVoltageResearch.com
Plasmasonic®1.3 DRSSTC Instruction Manual
ELECTROMAG ETIC FIELD HAZARD
This device when connected to a resonator will produce strong
electric and magnetic fields. Exposure to this field should be limited.
DO OT USE THIS KIT IF YOU HAVE A IMPLA TED BIOMEDICAL
DEVICE!
E ERGY STORAGE WAR I G
This device contains high voltage energy storage capacitors. Please
allow at least 5 minutes from the time the unit is unplugged to the
time you handle or move the Plasmasonic DRSSTC system. There are
two levels of bleed resistors installed in the system which are
designed to safely and quickly bleed down the energy storage
capacitors. The primary bleed resistor is a relay activated high power
resistor designed to quickly bleed the energy storage capacitors
upon removal of AC input power. The secondary bleed resistors are
smaller resistors which are placed across each energy storage
capacitor and will safely bleed the energy storage capacitors within 5
minutes after the removal of AC input power.