e-motion Premium series Manuel utilisateur

Premium Whirlpool
Operating and Installation Instructions


Ladies and Gentlemen,
Thank you for choosing our product.
Prior to installing the product and the initial start-up, please take some time
to read this manual carefully to familiarize yourself with the safety aspects.
Please open the package (wooden crate) using a cordless screw driver
(TX20 bit). Please save the crate until the whirlpool has been tested and installed.
If you have any questions or suggestions concerning your new hot tub,
feel free to use our customer hotline. Hotline: 020 - 34 99 50 19
TABLE OF CONTENTS
Safety instructions ................................................................................................ 4
Care and maintenance ........................................................................................ 4
Part names ........................................................................................................... 5-6
Specications and installation .................................................................... 7-8
Operating instructions.................................................................................9-10
Initial start-up / test run .................................................................................. 11
Final assembly ...............................................................................................12-15
INCLUDED IN THE SHIPMENT
WITH YOUR WHIRLPOOL
1 x waterfall spout and gasket (optional)
1x handheld shower head attachment (optional)
1x mounting material for the skirt, incl. wall mount
1x siphon / odor eliminator

4
SAFETY INSTRUCTIONS
1. Children or anyone needing assistance should not use the whirlpool spa
without supervision. People with heart conditions, high blood pressure
or diabetes or other serious illnesses should exercise increased caution or
consult a doctor before using the whirlpool tub.
2. Alcohol consumption or high levels of physical exhaustion may
represent a hazard during use.
3. Caution – Danger of slipping when entering and exiting the whirlpool tub.
Please note that there may be an increased risk of slipping due to residues
of bath additives on the tub bottom.
4. All water connections and electrical work must be performed by a specialist.
5. The water pump is equipped with dry-run protection and can only
be placed in operation when the water level sensors are covered with water.
6. The water pump, air pump and ozone generator require air circulation to
ensure heat dissipation. If you decide to tile the whirlpool tub, please ensure
adequate ventilation.
CARE AND MAINTENANCE
1. We recommend the use of 2000 grit sandpaper for the removal of
supercial scratches. Afterwards, the sanded surface must be polished.
2. For cleaning the hot tub surfaces, only use cleaners suitable for the
maintenance of sanitary-grade acrylic.
3. Do not use acidic or alkaline cleaning agents.
4. If the bottom air nozzles, side jets, back jets and the suction ttings are
clogged with hair etc., they can be unscrewed and cleaned.

5
3-unit xtures (optional)
Waterfall (optional)
Handheld shower head
(optional)
Side jets and suction tting
Drain and bottom
air nozzles
PART NAMES (Features may vary depending on the conguration.)

6
Back massage jets
Drain and overow tting
Venturi (air admixture valve)
LED touch-display
control panel
3-color light therapy LED

7
SPECIFICATIONS AND INSTALLATION
- 230 V voltage
- 16 A fuse
- 50 Hz frequency
- water supply hose (½ to ½ inch) (Important: No rigid pipe connection
between whirlpool tub and water line – risk of breaking!)
- 50 mm drain
Important information for the electrical installation
- All electrical work must be performed with the power shut off
(if applicable, remove the bathroom fuse).
- Make sure all electrical contacts with the connecting elements are
reliable (insert stripped wires completely into clamps; perform tension test);
this is especially important for the ground wire connection.
- Do not store extra wire (loops, individual ends of wires stripped too long etc.)
in the fuse box.
- Check to make sure the entire piece of equipment is properly connected.
Faulty connections and terminals may lead to equipment failures
or compromise of the safeguards provided.
Compliance with Protection Class IP 55
1. The external line enclosures (sheaths) must be inserted completely into
the screw mounting connections.
2. Any unused entry ports must be sealed or replaced by dummy plugs
made of insulating material.
3. Cable entry openings must be placed downwards or laterally.
4. The housing covers must be properly reattached.
5. Always make sure that electrical equipment is placed, installed and attached
in such a way that it cannot fall into the bathtub.
6. Upon completion of the electrical installation, an inspection and testing
(functional check) must be performed by a licensed electrician.

8
7. In addition, the effectiveness of the implemented protective measures,
ground and insulation connections, potential equalization, insulation status
etc. of the newly installed equipment must be veried and documented.
8. If the tub control is to be used in other (e. g. medical) areas, such as hospitals,
outpatient clinics, health spas and rehabilitation facilities, the additional
requirements for the installation of such systems must be complied with.
(We recommend that you contact us before attempting such an installation.)
Whirlpool tub installation (incl. optional xture elements)
- Connect the whirlpool tub to the water connections.
- Connect the tub drain to your sewer connection.
- If applicable, attach the waterfall spout on the bathtub rim (Ø 22 cm opening)
and place the gasket between the tub and the waterfall. Then connect the
waterfall with the supply line from the switch.
- If applicable, connect the overow with the supply and drain lines.
- If applicable, connect the handheld shower head attachment with the shower
head hose.

9
OPERATING INSTRUCTIONS
On/Off and key lock
Press Key 10 to activate the whirlpool system. This will activate the backlighting
of the touch control panel. If this is not followed by another key press, the key
lock will automatically turn on after approx. one minute. Press and hold Key 4 to
release/activate the key lock
Dry-run protection system (TLS)
The dry-run protection system is factory-installed on the outside of the tub, e. g.
with silicone. Following the nal assembly, the dry-run protection system is cove-
red. Please make sure during the initial start-up and test run that the LED turns on.
The system comprises a capacity proximity switch (dry-run protection – TLS) with
a maximum switching distance of 20 mm (tub wall thickness). To operate the pump,
a certain water level is required.
Water pump and massage jets
The water pump controls the back and side jets as well as the suction tting. Press
Key 1 to turn the water pump on and off. The water pump will not turn on or will
automatically turn off (TLS) if the water level is too low.
1water pump
2air pump
3heater
4key lock
5colored lighting LED
6ozone disinfection
7display
8plus
9minus
10 On/Off
*FM/Radio /Bluetooth
These functions are not
included in the feature set.
123
456
7
8
9
*
10

10
Venturi (air admixture valve)
If you open the Venturi valve while the water pump is running, the jet system will
be supplied with extra air, the water pressure increases and the massage effect is
intensied. In most cases, the valve is factory-preset set to the maximum value and
open.
Heater and water temperature
Please note that the heater can only be used while the water pump is running. To
turn on the heater, press Key 3. The preset temperature is 45°C (113°F) when the
heater is turned on. The selectable temperature ranges from 30°C and 50°C (86°F
to 122°F). Note: The recommended maximum bathing temperature for healthy
adults is usually 38°C (100°F). To adjust the temperature, press and hold Key 3
briey until the temperature display starts to ash. Now you can adjust the tempe-
rature using Key 8 (up) and Key 9 (down). When the actual temperature is shown
on the display, the adjusted temperature was applied.
Air pump and draining of residual water
The air pump controls the bottom air nozzles. Press Key 2 to turn the air pump on
and off. The air pump generally turns off automatically after about 45 minutes to
prevent overheating. Following automatic turnoff, the air pump can be re-activated
by pressing Key 2.
TIP: Once the water is completely drained from the tub, use Key 2 to activate the
air pump in order to drain the residual water from the bottom air nozzles.
Let the air pump run for a few seconds until no more water exits from the bottom
nozzles. Do not leave the hot tub unattended during this process and turn off the
air pump when nished.
3-color light therapy LED
Use Key 5 to turn the 3-color light therapy LED on and off.
The colors change automatically within a xed interval.
Ozone disinfection (O3)
Just use ozone disinfection while you are taking a bath. Please use ozone
disinfection only when the tub is lled with water and the water pump is turned
on to allow the ozone to spread in the hose system. Press Key 6 to turn ozone
disinfection on and off.
Table des matières
Autres manuels e-motion spa
Manuels spa populaires d'autres marques

Bestway
Bestway Lay-Z-Spa 54189 Manuel utilisateur

Jacuzzi
Jacuzzi ARGA ARG101C0110 Manuel de la liste des pièces

Morphy Richards
Morphy Richards Essentials PC4006 Manuel utilisateur

Softub
Softub PRESTIGE Manuel utilisateur

JNJ SPAS
JNJ SPAS SPA-318 Manuel d'installation

KIRAMI
KIRAMI Comfort Family Manuel utilisateur