DotFit Exerspy Manuel utilisateur

ARMBAND USER GUIDE

Purpose of the System .......................................................... 02
Wearing the Armband ...........................................................03
Removing the Strap/Wing Assembly From Armband.......... 03
Armband Care and Maintenance..........................................04
Status Indicators ................................................................... 05
Important Information About the Armband ........................ 07
Product Specifications...........................................................11
Accuracy.................................................................................12
User Environment .................................................................13
Regulatory Statement............................................................17
Copyright, Patent, and Trademark Notices...........................18
Table of Contents
exerspy armband
TM
1

2
User Guide
Intended Use
The exerspy calorie and activity tracking system works with the dotFIT Me Program
to record, analyze and report parameters. These objective health metrics enable you
to maintain a healthy weight and an active lifestyle, which are continually cited as the
keys to combating and managing serious medical conditions including obesity,
cardiovascular disease and diabetes. The information presented by the system can
be used by your physician or healthcare practitioner to assess your physical activity
level and help you reach dietary and weight control goals.
Risks and Benefits
The predominant benefit of the product is the enabling of the monitoring and
management of daily metabolic and lifestyle data in order to reach your activity and
weight goals. In addition to weight management, known benefits of increasing
activity levels include increased life expectancy, improved sleep, and enhanced
appearance and “self-perception”.
Analysis and post market surveillance indicates that the risks of using the product
are extremely low. No significant health risks have been identified. The most fre-
quently reported health risk, occurring in less then 1% of users, is a mild to severe
skin irritation resulting from wearing the armband. Following proper wear and
cleaning instructions often resolves this issue. If irritation continues, discontinue
use and consult a physician. Follow all instructions regarding how to properly wear
and clean the armband to minimize the chance of irritation. If you have a known
metal allergy consult your physician prior to using the product. Read the instruc-
tions provided and all cautions before using the armband.
Purpose of the System

3
Wearing the exerspy Armband
Refer to the enclosed Start Here! card for instructions
on how to start using your exerspy activity and
calorie tracking system.
The exerspy armband (the “armband”) is
designed to be worn on the back of the upper left arm
(the triceps) with the logo towards the shoulder and
the sensors touching the skin.
Slide the armband onto your left arm.1.
Adjust the strap so that it fits on your arm2.
comfortably, and secure the pull-tab. Ensure
that the sensors maintain continuous
contact with your skin at all times and that
the armband does not slide off your arm.
Be sure not to secure the strap too tightly.
Removing the Armband Strap From the Armband
Start with the armband text facing up. Apply1.
continuous downward pressure to the right
side of the armband until it separates from
the armband strap.
Reattach by first aligning the USB port with2.
the indentations on the left side of the strap/
wing assembly. Apply upward pressure to the
right side until it snaps into place.
exerspy armband
TM
TM
TM

4
User Guide
Clean the armband daily especially after sweating or when it becomes noticeably
moist or dirty. Disinfecting the armband with isopropyl alcohol may be required
occasionally. Failure to keep the armband clean or improper cleaning may irritate
the skin and affect the sensor performance.
Cleaning
To clean the armband: Gently wipe the side of the armband touching the skin
with a soft cloth or towel moistened with a mild soap and water. Wipe with a
clean damp cloth to remove any excess soap remaining. Use a dry, soft cloth or
towel to completely dry the armband before wearing it.
Never use solvents to clean the armband.
To clean the strap/wing assembly: Hand wash with mild soap and warm water,
rinse, then air dry. Machine drying may affect the performance and lifespan of
the strap.
Disinfecting
The armband may need to be disinfected occasionally. Wipe the entire armband
with a soft cloth dampened with 70% isopropyl alcohol. Allow the armband to
dry for 5-10 minutes before wearing it. Always disinfect the armband and replace
the armband strap prior to use by others.
DO NOT STERILIZE THIS UNIT.
Water Resistance
DO NOT IMMERSE THE ARMBAND IN WATER. The armband is not designed
to be used underwater or to come into continuous contact with water.
exerspy Armband Care and Maintenance
TM

5
Status Indicators
Power
The armband does not have a power button. When the armband makes secure
contact with your body it will power on automatically. This may take up to 10
minutes. Activation is indicated by a series of audio tones.
Battery
It is recommended to fully charge the battery before use. To charge the battery,
remove the armband strap and plug the USB cable into your PC. Then plug the
other end of the USB cable into the armband. The battery charges via the USB
cable from a completely depleted state to full capacity in approximately 3 hours.
The battery light will flash green when the armband is fully charged.
Starting with a fully charged battery, the armband battery will last for 5-7 days of
steady use before needing to be recharged.
To check the status of the battery, remove the armband from your arm and press
the Status Button. The battery light will turn on as follows:
battery before continuing use.
exerspy armband
TM
a

6
User Guide
Memory
During steady use the armband will hold 14 days of data.
To check the memory status, remove the armband and press the Status Button.
The memory light will turn on as follows:
upload data before continuing use.
Status Button
Status Lights
For more information or troubleshooting help, please go to www.dotFIT.com/exerspyhelp
or call Technical Support at 877.436.8348.

7
Important Information About the Armband
Follow operating instructions
CAUTION
The Waste Electrical and Electronic Equipment Regulations
indicates separate collection for electrical and electronic equipment
Electrical Safety
Non-ionized radiation
Type B Applied Part
FCC Logo
CE (Conformité Européenne) mark
exerspy armband
TM
Information on Proper Disposal of the exerspy Armband
Attention: If you want to dispose of the equipment, please do not use the ordinary
trash!
The product must not be disposed of with your other household waste. Instead, it
is your responsibility to dispose of your waste equipment by handing it over to a
designated collection point for the recycling of waste electrical and electronic equip-
ment. The separate collection and recycling of your waste equipment at the time
of disposal will help to conserve natural resources and ensure that it is recycled in
a manner that protects human health and the environment. For more information
about where you can drop off your waste equipment for recycling, please contact
your local authority, your household waste disposal service or the shop where you
purchased the product.
TM

8
User Guide
Cautions
Always consult a physician before starting any new diet or exercise program. This
system is not to be used for diagnostic purposes. This system is not intended as a
substitute for the medical advice or supervision of your personal physician.
CAUTION: This product is not defibrillation proof.
CAUTION: Do not get the device close to other devices that can cause
electromagnetic interferences of any nature.
CAUTION: EQUIPMENT not suitable for use in the presence of a FLAMMABLE
CAUTION: Medical electrical equipment needs special precautions regarding EMC
and needs to be installed and put into service according to the EMC information
provided on pages 14 –17. Portable and mobile RF communications equipment can
affect medical electrical equipment.
CAUTION: The equipment or system should not be used adjacent to or stacked with other
equipment and if adjacent or stacked use is necessary, the equipment or system should be
observed to verify normal operation in the configuration in which it will be used.
CAUTION: Keep the armband out of reach of children. It contains smaller, removable
parts which can become choking hazards.
CAUTION: The device and wireless accessories should not be used in airplanes,
hospitals, or locations where cellular telephones or electronic devices are prohibited.
CAUTION: Do not use unapproved accessories with the armband.

9exerspy armband
TM
CAUTION: Reminders should not be used for life-critical events, such as taking
certain medications, if they are vital to your daily health.
CAUTION: When the armband is on the arm, DO NOT connect it to the USB cable.
CAUTION: If you have known metals allergies, you should consult your physician
prior to wearing.
CAUTION: Check armband for sharp edges or damage before each use.
CAUTION: Avoid wearing the armband when it has been exposed to excessively hot
temperatures (i.e., direct sun exposure) to avoid burns to the skin.
CAUTION: Users should avoid wearing the armband excessively. To reduce
potential for skin irritation wear the armband for a maximum of 23 hours per day.
CAUTION: The tab should be aligned with the strap to avoid unintended contact
with the skin which may cause scratching.
CAUTION: Do not wear the armband on an open wound, sore or burn.
CAUTION: Be careful not to over-tighten the armband while on your arm. If you
feel constriction or loss of circulation at any time, simply loosen the adjustable
strap and re-fasten it to a more comfortable setting.
CAUTION: Each material was chosen for its precedent in other skin contact prod-
ucts or has been independently approved for skin contact. However, everyone’s
skin is different and you may experience irritation or redness after wearing the
armband. If this occurs, discontinue use and consult your physician.
Important Information About the Armband (Continued)
Autres manuels pour Exerspy
1
Table des matières