DIGITIZE DDI-11E Mode d’emploi

DDI-11E
Dual Line Digital Dialer Receiver
Installation & User Manual
Digitize, Inc.
158 Edison Road
Lake Hopatcong, New Jersey 07849
Tel: (973) 663-1011 Part Number: 700289-0001
E-mail:info@digitize-inc.com Revision: B
Website: http://www.digitize-inc.com Issue Date: 10/21

Digitize, Inc.
158 Edison Road
Lake Hopatcong, NJ 07849-2217
The Digitize logo (stylized) is a registered trademark of Digitize, Inc.

PROPRIETARY NOTICE
AND
DISCLAIMER
DIGITIZE, INC.
158 EDISON ROAD
LAKE HOPATCONG, NJ 07849-2217
PH: (973) 663-1011
E-Mail: info@digitize-inc.com
Website: http://www.digitize-inc.com
This manual has been prepared by DIGITIZE, INC. for use by its licensees,
distributors and customers. The information contained herein is the property of
DIGITIZE, INC. and may not be copied, disclosed or reproduced, in whole or in part,
without the prior written approval of DIGITIZE, INC. Any unauthorized disclosure to,
or use of the enclosed information by, unauthorized third persons shall void any and
all representations, warranties and obligations on the part of DIGITIZE, INC.
DIGITIZE, INC. reserves the right to make changes to the specifications and
material contained herein without prior notice. The information and/or examples
(including, but not limited to circuitry, wiring diagrams, programming, the operation
or use shown) described in this manual are intended solely to illustrate the operating
principles of the particular product. They are not a warranty, representation or
guarantee that a particular example or use shown will perform in a particular
situation. They are given for illustration purposes only. DIGITIZE, INC. shall not be
responsible, nor does it represent, that any example of illustration will perform in a
particular environment or practice unless it specifically makes a representation to
that effect.
The material set forth herein is for informational purposes only, and DIGITIZE, INC.
assumes no patent liability with respect to any information or illustrations contained
herein.

FCC NOTICE
In compliance with Paragraph 15.105 of the FCC Rules and Regulations, the
following notice is provided.
NOTE: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy, and, if not installed and used in
accordance with the instruction manual, may cause interference to radio
communications. Operation of this equipment in a residential area is likely to cause
interference, in which case the user will be required to correct the interference at his
own expense.
P/N 770120 Rev C

Table of Contents
1 Introduction ........................................................................................... 1-1
1.1 Purpose..........................................................................................................................................1-1
1.2 Scope.............................................................................................................................................1-1
1.3 System Organization......................................................................................................................1-1
2 Describing the System ........................................................................... 2-1
2.1 What is the DDI-11E Receiver?.....................................................................................................2-1
2.2 How are systems configured? ........................................................................................................2-2
2.3 What Dialer Panels work with the DDI-11E Interface?..................................................................2-3
2.4 Description of DDI-11E Parts........................................................................................................2-4
2.4.1 DDI-11E Front Panel..............................................................................................................2-4
2.4.2 DDI-11E Rear Panel...............................................................................................................2-5
2.5 Retrofits / Upgrades.......................................................................................................................2-6
3 Installation............................................................................................. 3-1
3.1 Handling........................................................................................................................................3-1
3.1.1 Unpacking and Inspection ......................................................................................................3-1
3.1.2 Precautions.............................................................................................................................3-1
3.2 Parts of the DDI-11E.....................................................................................................................3-1
3.3 Installing the DDI-11E. .................................................................................................................3-2
4 Setting up the System............................................................................. 4-1
4.1 Setting up the DDI-11E .................................................................................................................4-1
4.2 Setting up the System 3505............................................................................................................4-1
4.3 Main Menu....................................................................................................................................4-3
4.4 Configuration Tables.....................................................................................................................4-3
4.4.1 Translate Alarm Codes to Zones.............................................................................................4-4
4.4.2 Set English Equivalents..........................................................................................................4-6
4.4.3 Opening and Closing Codes....................................................................................................4-7
4.4.4 Configuration Table Details....................................................................................................4-9
4.4.5 Data Loss .............................................................................................................................4-10
4.5 Main Menu Selections.................................................................................................................4-10
4.5.1 Customer ADD/CHG/DEL account......................................................................................4-10
4.5.2 Set up configuration tables (translations)..............................................................................4-12
4.5.3 Copy one config table to another ..........................................................................................4-13
4.5.4 Convert SIA designators to Contact ID text..........................................................................4-14
4.5.5 DDI/Intellitize Various setup selections................................................................................4-14
4.5.6 Force a daily test after the following.....................................................................................4-15
4.5.7 Rings to Answer the Phone...................................................................................................4-16
4.5.8 On the Fly Zone Conversion.................................................................................................4-17
4.5.9 Sort Customers in numeric order & exit................................................................................4-17
4.5.10 Select DDI-9E starting handshake sequence .......................................................................4-17
5 Operation............................................................................................... 5-1
5.1 Redundant Operation.....................................................................................................................5-2
5.2 Missed Dialers...............................................................................................................................5-2
5.3 Data Loss ......................................................................................................................................5-3
6 Testing the System................................................................................. 6-1
7 Appendix A ............................................................................................... i
8 Appendix B.............................................................................................. vi


700289-0001 Rev. B 10/21 1-1
1 Introduction
1.1 Purpose
The purpose of this manual is to inform the user on how to install, test, operate, and
maintain the DDI-11E Dual Line Receiver.
Although the primary subject of this manual will be the DDI-11E Dual Line
Receiver, the manual will also provide information on the System 3505.
1.2 Scope
This document is intended as an introduction and tutorial on the installation and use
of DDI-11E Dual Line Receiver. The DDI-11E Dual Line Receiver was designed
specifically for Fire and Security applications, therefore most of the examples and
exercises here also deal with these applications.
This manual assumes the reader has a background in electronics. Furthermore, this
manual assumes the reader is familiar with Digital Dialer Interface Panels, Fire
panels, RS-232 Interfaces, Ethernet interfaces, and the Digitize System 3505.
1.3 System Organization
The manual is broken down into six major areas of discussion for the DDI-11E
Digital Dialer Receiver and other components of the dialer interface. They are:
•Introduction
•System Description
•Installation.
•Setup
•Operation
•Testing

Introduction Digitize Inc.
1-2 700289-0001 Rev. B 10/21
This page is intentionally blank.

700289-0001 Rev. B 10/21 2-1
2 Describing the System
Chapter 2, Describing the System will explain what a DDI-11E Receiver is, how it
is connected and setup, and what type of information it reports.
2.1 What is the DDI-11E Receiver?
The DDI-11E is a dual line dialer receiver and one of the components of the
Digital Dialer interface option. The DDI-11E allows the SYSTEM 3505 to receive
alarm information through the dial-up telephone network. The dialer option
software provides conversion of coded information from the receiver into the
proper format for processing by the SYSTEM 3505.
Figure 2-1, DDI-11E Dual Line Digital Dialer Receiver
The DDI-11E is a dual line external dialer receiver capable of processing a variety of
dialer protocols. The DDI-11E is connected to a SYSTEM 3505 with the Digital
Dialer option, thus permitting two incoming telephone lines to be monitored.
DDI-11E receivers are equipped with Caller ID. If the Alarm monitoring location
subscribes to Caller ID, the Caller ID information is printed at the System 3505 after
the first ring is received and the DDI-11E processes the data.

Describing the System Digitize Inc.
2-2 700289-0001 Rev. B 10/21
The DDI-11E receiver is connected to the System 3505 via a supervised RS-232
Cable. An additional connection to the System 3505 provides the operating power
for the DDI-11E, both normal and standby power.
2.2 How are systems configured?
Redundant operation can take several forms. When using a redundant head end,
one dual-line DDI-11E can be installed on each of the redundant units. The online
unit will answer the phone. The backup unit will be in standby. Both DDI-11E units
will have the phone lines in parallel. Or, one dual-line DDI-11E may be used
between the redundant SYSTEM 3505 units. Simply route the RS-232 signals via
the T-Bar so that the online unit has access to the DDI-11E.
Figure 2-2, Simple Standalone System
Fire code requires two phone lines to the monitoring equipment. On SYSTEM 3505
units with DDI-11E, if the first phone line is unable to make a connection, the phone
automatically hunts to the second phone line. (Please note: The hunt feature is
provided by the local phone company, not Digitize, Inc. equipment.).
Figure 2-3, Completely Redundant System
On installations with two SYSTEM 3505'S, automatic transfer, and a DDI-11E
module for each unit, the backup SYSTEM 3505 provides a second system of
coverage. In this case, redundant operation would require at least two SYSTEM
3505 units and two DDI-11E modules