Receiver E19
8 / 8 28506100_E19_EN_2012-08-07_EN.docx
8 Declaration of Conformity
Dickert Electronic GmbH declares with complete responsibility, that the product meets the
regulations of Directive 1999/5/EC of the Council of the European Union. The complete text
of the Declaration of Conformity can be found on the website www.Dickert.com under
"Download“.
9 Environmental protection / Disposal
The receiver does not contain any integrated batteries. Solely ROHS-conforming components
are used. Properly dispose of old and defective appliances and device parts in a collecting
point! Do not put them in domestic waste!
10Troubleshooting
Errors Possible causes Comments / Actions
LED remains off on
the socket receiver
during transmitter
activation.
Battery in the transmitter is
empty. Check / replace battery.
Transmitter not taught. Teach transmitter.
Transmitter has incorrect cod-
ing schematic. Delete all transmitters and teach again.
No power on the socket. Check mains fuse (circuit breaker).
Transmitter faulty. Replace transmitter.
Socket receiver faulty. Replace receiver.
LED on the wireless
socket goes on with
transmitter activation,
but the "consumer"
does not react.
Consumer possibly switched
off? Check and switch on if necessary.
"Consumer" faulty. Check whether the "consumer" functions if it is
run directly from mains. If yes, replace the wire-
less socket.
The "consumer" al-
ways goes off again
automatically after a
specific time.
Check whether the LED on the
wireless socket blinks when it is
switched on. If yes, the timer
mode was accidentally activat-
ed.
Delete timer.
11Technical data
The operation of the control system is only allowed according to these specifications / data!
Receiving frequency: 433.92 MHz/AM or 868.30 MHz/AM (see imprint)
Coding: 12 bit, 18 bit or Keeloq, self-teaching, max. 13 codes (transmitter keys) can be
taught
Antenna: integrated (no ext. antenna required)
Operating voltage: 230 V, ± 10 % 50 Hz
Power consumption: <0.5W (standby operation)
Output: max. 1000 W active load, 500 W lamp load, internal fuse (T5A)
Switch off timer: programmable from 1s to approx. programmierb18 h, in 1s intervals
Operating
temperature:
-20° C to +35° C at 20 % to 90 % rel. humidity, only indoor installation allowed.
Dimensions: approx. 96 mm x 64 mm x 49 mm (L x W x H) housing ABS, IP 20, self-extinguishing
Weight: approx. 155 g