DHR 230RCB Series Manuel technique

Navigation Lights
Signalling Lights
Searchlights
Whistles
TECHNICAL DOCUMENT
DHR 230RCB220
Remote Controlled Searchlight
Den Haan Rotterdam
S
i
n
c
e
1
9
2
2

2Version 1.1 January 2019
Den Haan Rotterdam
(Intentionally blank page)

3Version 1.1 January 2019
Den Haan Rotterdam
Safety notes:
• Turn power off before inspection, installation or removal
• Keep combustible materials away from lamp
• Do not exceed 105% of rated voltage
• Allow lamp/fixture to cool before handling
• Do not use the searchlight if outer glass is scratched or broken
Damage due to inappropriate handling is
not covered by the warranty.
© Copyright, Den Haan Rotterdam B.V.
Version 1.1 January 2019
This document contains proprietary information that is protected by copyright.
All rights reserved.
!

4Version 1.1 January 2019
Den Haan Rotterdam
Den Haan Rotterdam is a family-owned company established in 1922. Started as a small tinsmith, it has
evolved into a globally respected producer of navigation lights, searchlights, air horns and a wide range of
nautical lamps made from copper and brass. By introducing products with advanced LED-technology, DHR
has safeguarded a visibly safe future for marine vessels in all weather conditions.
With the 230RCB-series searchlight, DHR introduces an entry level remote controlled LED searchlight. The
75W LED engine produces a color output of 5.000K and an intensity close to the same performance levels
of 1.000W halogen searchlights. Using the best available parabolic mirror reflectors on the market, a crisp
& clear spot with no visible stray light has been ensured. The 230RCB is equipped with an unique bracket
design to realize an extreme downward vertical angle. This is specifically useful for close range targets.
Positions on high structures or foremasts of inland navigation vessels, where high angles up to 60° are
desired, the 230RCN is the answer.
DEN HAAN ROTTERDAM B.V.
D.M. Den Haan
Managing Director
PREFACE
QUALITY STANDARDS
Excellent Optics
Maintenance Friendly
Light Weight Construction
IP66 Water Ingress Protection
Remote Control
LED Technology
Large Vertical Angle

5Version 1.1 January 2019
Den Haan Rotterdam
TABLE OF CONTENTS
1. Mounting instructions 6
2. Specifications 8
3. Dimensions 11
4. Photos 13
5. Wiring diagrams 14
6. Maintenance and correct use 19
7. Replacing of motor frame 20
8. Recommended spare parts 21

6Version 1.1 January 2019
Den Haan Rotterdam
1. MOUNTING INSTRUCTIONS
Mounting the panel
Place the control panel inside the wheelhouse, where it is protected against weather influences. The panel
has been designed in order to be flush-mounted in an instrument cabinet, as shown in the illustration below.
The minimum space needed behind the panel is 110 mm. (depth)
97 ± 1 mm
97 ± 1 mm
Cut-out panel
Searchlight installation
Install the searchlight in a horizontal upright position with sufficient space around the head of the searchlight
to ensure it can move freely. The dimensions can be found on page 9.
Bolt M10x (60 + M)
Insulation sleeve
Lantern base
Insulation sleeve
Washer M10
Mounting plate Min. 5 mm
Nut M10
M
All dimensions in mm
Fasteners
• The permissible torque should be 8 Nm
• Use only A4-grade stainless steel
Caution!
Even though the housing is made of corrosion resistant materials, galvanic corrosion may still occur. To
prevent galvanic corrosion use the supplied insulation sleeves to isolate the aluminium housing from
other metal parts.
4 x Ø10
162,5
162,5
Warning!
Den Haan Rotterdam does not accept responsibility for any damage if the searchlight is in-
stalled incorrectly and/or used improperly. When in doubt consult a qualified electrical techni-
cian.
!

7Version 1.1 January 2019
Den Haan Rotterdam
Electrical installation
Install the electrical wiring according to the wiring diagrams showed on pages 11 - 14. Keep the distance
between the power supply and halogen lamp as short as possible. Long wires will increase a voltage drop
near the halogen lamp, which affects the light output.
Cable glands
ØD
Cable
• Prefered diameter D is 7 - 12 mm
• Material: Neoprene H07RN-F
Cable too tight!
This gives unwanted stress at the sealing of the
cable gland and water ingress will occur.
Include cable slack at the entering
point of the cable gland
Replacing cable gland
• Use gasket between housing
and cable gland
• Tighten firmly (6Nm) with
wrench
Remove the plug before placing the cable.
If no cable is connected, leave the plug in place!
Note
The cable glands on the searchlight prevent water ingress. Do not use (electrical) tape to cover the
cable where it enters the cable gland as this will cause water ingress. Do not use a rubber or shrink-
able cover on the cable gland to improve water tightness.

8Version 1.1 January 2019
Den Haan Rotterdam
2. SPECIFICATIONS
Control panel
Model PAN2011
Dimensions
Depth 110 mm
Width 110 mm
Weight 0,6 kg
Electrical
Voltage 24 VDC±20%
Maximum wattage 20 W
Fuse T2A
Electrical insulation class III
Housing
Front Stainless steel 316
Back Aluminium, painted black
Operating temperature 0° / + 45° C
Switches
1. BEAM ON/OFF, switches the searchlight on or off.
2. Joystick, controls the direction of the movement.
3. ON/OFF, switches the panel on or off.
Potentiometers
4. SPEED U/D, speed of the movement up and down.
5. SPEED L/R, speed of the movement left and right.
ON/OFF
BEAM ON/OFF
SPEED U/D SPEED L/R
1
3
2
4 5

9Version 1.1 January 2019
Den Haan Rotterdam
Searchlight
Model 230RCN220
Dimensions
Height 617 mm
Width 331 mm
Weight 16 kg
Electrical
LED-driver 230 VAC / 75W
Motor voltage 6-13 VDC
Preferred cable type H07RN-F
Cable diameter Ø 6-12 mm
Optics
Mirror Parabolic mirror reflector Ø 230 mm
Range 775m
Adjustable Focus No
² 6° x 6°
Luminous intensity 600.000 cd
LED
Model CLU731
Luminous flux 8.767 lm
Rated LED voltage -
Rated LED wattage -
Average life-time 50.000 h
Color temperature 5000 K
Base -
Heater
Type PTC-heater
Voltage 24VDC
Maximum wattage 70 W
Motor Unit
Tilt + 30° / - 60°
PAN 340°
Max. speed left / right approx. 34°/ sec
Max. speed up / down approx. 3,2° / sec
Housing
Material Chromated seawater resistant aluminium
Finish UV resistant powder coating - White RAL9016
Front glass Hardened front glass
Seals Silicone / Neoprene, black
Cable gland M25x1.5
Operating temperature - 25° / + 40° C
Ingress protection class IP66 c/w Membrane vent

10 Version 1.1 January 2019
Den Haan Rotterdam
(Intentionally blank page)
Ce manuel convient aux modèles suivants
2
Table des matières
Autres manuels DHR Projecteur
Manuels Projecteur populaires d'autres marques

VIZULO
VIZULO Micro Martin Guide de l'utilisateur

EuroLite
EuroLite LED IP FL-100 SMD Manuel utilisateur

Cooper Wheelock
Cooper Wheelock XB12 Manuel utilisateur

Allen + Roth
Allen + Roth 17624-000 Manuel utilisateur

ADJ
ADJ 4 STAGE PAK Manuel utilisateur

Cooper Lighting
Cooper Lighting EGL91SW233 Manuel utilisateur