DEVOLA DV16L Manuel utilisateur

DEHUMIDIFIER INSTRUCTION MANUAL
Model (s):
DV16L/DV16LWF
DV20L/DV20LWF

1
Please keep this manual carefully for future reference!
Thank you for purchasing our Devola dehumidifier. Be sure to read this manual carefully
before using it. Any questions, please contact a professional service, or alternatively our
customer service team for help.
1. BEFORE YOU BEGIN
Please read the operating instructions carefully before using your dehumidifier for the
first time.
1.1 PRODUCT DESCRIPTION
The dehumidifier is used to remove excessive moisture from the air. The resulting reduction in
relative humidity protects buildings and their contents from the adverse effects of excess humidity.
The environmentally friendly R290 is used as the refrigerant. R290 has no damaging influence
on the ozone layer (ODP), a negligible greenhouse effect (GWP) and is available worldwide.
Because of its efficient energy properties, R290 is highly suitable as a coolant for this application.
Special precautions must be taken into consideration due to the coolant's high flammability.
SYMBOLS FROM THE UNIT AND USER MANUAL
warning
This unit uses a flammable refrigerant.
If the refrigerant leaks and comes in contact with fire or
another heating source, it will create a harmful gas and
there is risk of fire.
Read the USER MANUAL carefully before operation.
Further information is available in the USER MANUAL,
SERVICE MANUAL, and the like.
Service personnel are required to carefully read the USER
MANUAL and SERVICE MANUAL before operation.

2
1.2 THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY
⚫This appliance is intended for domestic use but can also be for commercial use if the
environment is safe to do so.
⚫This appliance can be used by children aged 8 years and above. It can also be used by
individuals with reduced physical, sensory, or mental capabilities if they have been given
supervision or instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children aged below 8 years should not play with or use the
appliance. Cleaning and user maintenance should not be made by children 8 years and
above without supervision.
⚫The unit is designed only for use with R-290 (propane) gas as the designated refrigerant.
⚫The refrigerant loop is sealed. Only a qualified technician should attempt to service!
⚫Do not discharge the refrigerant into the atmosphere.
⚫R-290 (propane) is flammable and heavier than air.
⚫It collects first in low areas but can be circulated by the fans.
⚫If propane gas is present or even suspected, do not allow untrained personnel to attempt
to find the cause.
⚫The propane gas used in the unit has no odor.
⚫The lack of smell does not indicate a lack of escaped gas.
⚫If a leak is detected, immediately evacuate all persons from the device’s location and
contact the local fire department to advise them that a propane leak has occurred.
⚫Do not let any persons back into the room until the qualified service technician has arrived
and that technician advises that it is safe to return to the device location.
⚫No open flames, cigarettes or other possible sources of ignition should be used inside or
in the vicinity of the units.
⚫Component parts are designed for propane and non-incentive and non-sparking.
Component parts should only be replaced with identical repair parts.
FAILURE TO ABIDE BY THESE WARNING COULD RESULT IN AN EXPLOSION, DEATH,
INJURY AND PROPERTY DAMAGE.

3
2. FOR YOUR SAFETY
Your safety is of upmost concern to us!
Please read this manual carefully and fully understand before operating your dehumidifier.
2.1 OPERATIONAL PRECAUTIONS
WARNING- to reduce the risk of fire, electric shock or injury to persons or property:
⚫If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons to avoid a hazard.
⚫The appliance should be disconnected from its power source during maintenance.
⚫Always operate the unit from a power source of equal voltage, frequency and rating as
indicated on the product rating label.
⚫Always use a power outlet that is grounded.
⚫Unplug the power cord when cleaning or when not in use.
⚫Do not operate with wet hands. Prevent water from spilling onto the unit.
⚫Do not immerse or expose the unit to rain, moisture or any other liquid.
⚫Do not leave the unit running unattended. Do not tilt or turn over the unit.
⚫Do not unplug while the unit is operating.
⚫Do not unplug by pulling on the power cord.
⚫Do not use an extension cord or an adapter plug.

4
⚫Do not put objects on the unit.
⚫Do not climb or sit on the unit.
⚫Do not insert fingers or other objects into the air outlet.
⚫Do not touch the air inlet or the aluminum fins of the unit.
⚫Do not operate the unit if it is dropped, damaged or showing signs of product malfunction.
⚫Do not clean the appliance with any chemicals.
⚫Ensure the unit is far away from fire, inflammable, or explosive objects.
⚫The unit should be installed in accordance with national wiring regulations.
⚫Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacture.
⚫The appliance should be stored in a room without continuously operation sources (for
example: open flames, an operating gas appliance or an operating electric heater).
⚫The appliance should be stored when out of use for long periods, to prevent mechanical
damage from occurring.
⚫Do not piece or burn, even after use.
⚫Be aware that refrigerants may not contain an odor.
⚫Pipework should be protected from physical damage and should not be installed in an
unventilated space, if that space is smaller than 4m².
⚫Compliance with national gas regulations should be observed.
⚫Keep any required ventilation openings clear of obstruction.
⚫The appliance should be stored in a well-ventilated area where the room size corresponds
to the room area as specified for operation.

5
Any person who is involved with working on or breaking into a refrigerant circuit should
hold a current valid certificate from an industry-accredited assessment authority, which
authorizes their competence to handle refrigerants safely in accordance with an industry,
recognized assessment specification.
Servicing should only be performed as recommended by the equipment manufacturer.
Maintenance and repair requiring the assistance of other skilled personnel should be carried out
under the supervision of the person competent in the use of flammable refrigerants.
If you do not understand something or need help, please contact the dealer services
2.2 SAFETY PRECAUTIONS ON SERVICING
Please follow these warnings when to undertake the following when servicing a dehumidifier
with R290.
2.2.1 Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety checks are
necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system,
the following precautions should be complied with prior to conducting work on the system.
2.2.2 Work procedure
Work should be undertaken under a controlled procedure to minimize the risk of a flammable
gas or vapor being present while the work is being performed.
2.2.3 General work area
All maintenance staff and others working in the local area should be instructed on the nature of
work being carried out. Work in confined spaces should be avoided. The area around the
workspace should be sectioned off. Ensure that the conditions within the area have been made
safe by control of flammable material.
2.2.4 Checking for presence of refrigerant
The area should be checked with an appropriate refrigerant detector prior to and during work, to
ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak
detection equipment being used is suitable for use with flammable refrigerants, i.e. no sparking,
adequately sealed or intrinsically safe.

6
2.2.5 Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any associated parts,
appropriate fire extinguishing equipment should be available to hand. Have a dry powder or
CO2 fire extinguisher adjacent to the charging area.
2.2.6 No ignition sources
No person carrying out work in relation to a refrigeration system which involves exposing any
pipework that contains or has contained flammable refrigerant should use any sources of
ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition
sources, including cigarette smoking, should be kept sufficiently far away from the site of
installation, repairing, removing and disposal, during which flammable refrigerant can possibly
be released to the surrounding space. Prior to work taking place, the area around the
equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks.
“No Smoking” signs should be displayed.
2.2.7 Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before breaking into the
system or conducting any hot work. A degree of ventilation should continue during the period
that the work is carried out. The ventilation should safely disperse any released refrigerant and
preferably expel it externally into the atmosphere.
2.2.8 Checks to the refrigeration equipment
Where electrical components are being changed, they should be fit for the purpose and to the
correct specification. At all times, the manufacturer’s maintenance and service guidelines should
be followed. If in doubt consult the manufacturer’s technical department for assistance.
The following checks should be applied to installations using flammable refrigerants:
– The charge size is in accordance with the room size within which the refrigerant containing
parts are installed.
– The ventilation machinery and outlets are operating adequately and are not obstructed.
– If an indirect refrigerating circuit is being used, the secondary circuit should be checked for the
presence of refrigerant.
– Marking to the equipment continues to be visible and legible. Markings and signs that are
illegible should be corrected.

7
3 Color Digital Display
Front shell
– refrigeration pipe or components are installed in a position where they are unlikely to be
exposed to any substance which may corrode refrigerant containing components, unless the
components are constructed of materials which are inherently resistant to being corroded or are
suitably protected against being so corroded.
2.2.9 Checks to electrical devices
Repair and maintenance to electrical components should include initial safety checks and
component inspection procedures. If a fault exists that could compromise safety, then no
electrical supply should be connected to the circuit until it is satisfactorily dealt with. If the fault
cannot be corrected immediately but it is necessary to continue operation, an adequate
temporary solution should be used. This should be reported to the owner of the equipment, so
all parties are advised.
Initial safety checks should include:
-those capacitors are discharged: this should be done in a safe manner to avoid possibility of
sparking.
-that there no live electrical components and wiring are exposed while charging, recovering, or
purging the system.
-that there is continuity of earth bonding
3. PRODUCT OVERVIEW
Air Outlet
Castors
Control Panel

8
3.1 FEATURES
✓Powerful moisture removal (up to 20L/day dehumidification)
✓Humidity Monitor shows current air humidity
✓Auto mode automatically adjusts humidity levels
✓A 12-hour timer to set the time of operation
✓Effectively removes moisture, dust from the air
✓Low power consumption-energy efficient
✓Quiet fan has two speed settings
✓Auto-Defrost at low temperature
✓Auto shut-off/ auto restart
✓Electronic control
✓Laundry drying function
✓Antibacterial Filter
✓Continuous drainage or 4L water tank
✓Wi-Fi Function (Applicable to DV16LWF and DV20LWF only)
Handle
Air Filter
Back Shell
Top panel
Continuous drainage
口
Water tank

9
4. INSTALLATION
4.1 LOCATION
1. Place the unit on a firm, level surface in an area with at least 30cm of free space around it to
allow for proper air circulation.
2. Never install the unit where it could be subject to:
⚫Heat sources such as radiators, heat registers, stoves or other products that products that
produce heat.
⚫In an area where oil or water may be splashed
⚫Direct sunlight
⚫Mechanical vibration or shock
⚫Excessive dust
⚫Lack of ventilation, such as cabinet or bookcase
⚫Uneven surface
WARNING
Install the unit in rooms which exceed 4m².
Do not install the unit in a place where inflammable gas may leak.