Devilink CC Manuel utilisateur

Devilink™ CC – Central Controller
System Overview and Installation Manual
INT

2
Devilink™ System Overview ................................................................................... 2
1.0 Placement of Devilink™ CC ........................................................................... 5
2.0 Mounting of Devilink™ CC............................................................................. 6
3.0 Configuration of Devilink™ .......................................................................... 7
4.0 Modifying an exiting Installation................................................................ 13
5.0 Troubleshooting ............................................................................................... 20
6.0 Technical specifications ................................................................................. 23
Devi Warranty .............................................................................................................. 26
Devilink™ is a wireless control system for electrical floor heating.
The central brain in the system is the Devilink™ CC (Central
Controller) equipped with a colour touch screen. From this
you can control the entire installation. The Devilink™ CC
communicates wirelessly with all other Devilink™ devices in
the installation.
If you want to operate on room temperature you have the option
of installing a Devilink™ RS (Room Sensor). This has a built-in
room sensor and thus measures the ambient temperature. You
can also adjust the temperature with Devilink™ RS
The Devilink™ RS (Room Sensor) has a built-in temperature
sensor which measures the ambient temperature. It allows
you to control the heating based on room temperature, in the
specific room where installed. With the Devilink™ RS you can also
adjust the temperature.
Devilink™ PR (Plug in relay) is a device supporting two types of
operation modes, either for controlling heating element or other
electrical equipments ON/OFF manually or by schedule.
Index / Devilink™System Overview

3
Devilink™ System Overview
When using Devilink™ PR as heating regulation you also have
to install a Devilink™ RS, which allows you to control the
heating based on room temperature, in the specific room
where installed. With the Devilink™ RS you can also adjust the
temperature.
Devilink™ PR is to be put in to a socket/outlet together with a
SCHUCKO plug.
Devilink™ HR (Hidden relay) is a device supporting two types
of operation modes, either for controlling heating element or
other electrical equipments ON/OFF manually or by schedule.
When using Devilink™ HR as heating regulation you also
have to install a Devilink™ RS, which allows you to control
the heating based on room temperature, in the specific room
where installed. With the Devilink™ RS you can also adjust the
temperature.
Devilink™ HR is to be mounted in to a build in box in the wall.
Devilink™ FT (Floor Thermostat) or FTS (FT with sensor)
is one device supporting 3 types of operation modes, for
controlling of heating elements or other electrical equipments
ON/OFF manually or by schedule.
By controlling of floor heating DEVI always recommends
installing of a floor sensor.
Comfort heating – where a comfortable warm surface of the floor is
required you have only to connect a floor sensor to the Devilink™ FT as
heating regulation.
By Total heating you have to connect a floor sensor to the Devilink™ FT and
combined the installation with a Devilink™ RS, which allows you to control
the heat through both air and floor measurements. Devilink™ FT is to be
mounted in to a build in box in the wall or external box on the Wall.

4
Installation scenario:
Devilink™ System Overview
devireg™550
devireg™550
22.
0
22.
0
Devilink™ RS
Devilink™ HR or PR Devilink™ CC Devilink™ FT

5
Limitations – Devilink wireless controls
The Devilink wireless system’s transmission range is sufficient for most appli-
cations; however each building has different obstacles affecting communi-
cation and maximum transmission distance. If communication trouble exists
DEVI suggests that accessories would be required to support the system,
such as repeaters. In exceptional cases the wireless system may not be suit-
able for your installation.
Not on a wall where it will be subjected to direct sunlight.
Installation height should typically be between
140-170 cm.
In wet rooms it should be installed on an even surface,
according to local building regulations.
At least 50 cm away from windows/doors that will be left
open occasionally.
Not on the inner side of a wall facing the outside.
1. Placement of Devilink™ CC

6
The Devilink™ CC can be installed with either a
Do not power the Devilink™ CC until the manual tells you to do so.
Do not remove the protective film on the touch screen, the end user
should do this.
Mounting Devilink™ CC with In-Wall PSU:
• HoldthePSUoverthewallboxandmarkupthe4screwholes.
Make sure the top is level.
• Drillholesandputttingplugsin.
• ConnectthePSUaccordingtotheconnectiondiagramonthebackside.
• MountthePSUwiththe4screws.
Mounting Devilink™ CC with NSU:
• Holdthemountingplateonthewallandmarkupthe4screwholes.
Make sure the top is level.
• Drillholesandputttingplugsin.
• Mountthemountingplatewiththe4screws.
Do not mount the Devilink™ CC yet.
• ConnecttheNSUtoapoweroutlet.
Now mount all the room units according to their manuals. When that is done
continue with Configuration.
Devilink™ PSU (in-wall Power Supply)
or with a
2. Installing of Devilink™ CC
Devilink™ NSU (Net supply)

7
Start only at this point when all devices (FT, RS, HR and PR) have been
mounted in the rooms.
Adding devices to the system:
When you want to attach devices like FT, RS, HR, PR to your system the CC
must be within 1.5 meter from the device. To enable this, a battery pack,
Devilink™ BSU, is offered as an installer tool.
a. Put 10 fresh AA alkaline batteries in the BSU by sliding the lid off . Be
aware of the correct battery polarity. Slide the lid back on and attach the
Battery Pack BSU on to the back of the Devilink™ CC. When you are ready
to do the commissioning turn the switch located on the BSU to the ON
position.
Devilink™ CC will now start up, this takes several minutes. Please be patient…
Devilink™ BSU (Battery Supply Unit)
3. Configuration of Devilink™

8
b. When the system is powered for the first time you will be asked to set
Country, Language and Date/Time.
c. Remove the front cover from the CC by gently pulling it off. Press and
hold the setup pin with a pen for 3 seconds to start the installer menu.
If you are in doubt you can always press in
the lower right hand corner to get on screen
help.
3. Configuration of Devilink™
Operation mode
Devilink™ supports two types of operation modes.
1. Heating regulation. Go to section 3.d
2. ON/OFF function. Go to section 4.2

9
d. Now create the rooms where the local units are installed.
Add New Room:
The Configure Room menu now appears.
Press Room Devices and then Add a Device
3. Configuration of Devilink™

10
Repeat this step until all devices in the room have been added
When you have completed adding all the
devices for the room, you will get an overview
of the devices associated to the room.
Max 1.5 m
3. Configuration of Devilink™
Devilink™ automatically selects the regulation principle according to the
types of devices in the room.
If you want to change regulation, first read section 4.3 and then choose
Heating control. This is also where you set the maximum limit for your
floorings.