DEVI DEVIlink CC Manuel utilisateur

Installation Guide
DEVIlink™ CC
Central Controller
www.DEVI.com

DEVIlink™ CC
Installation Guide2
Table of Contents
1 Introduction � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 4
2 Guidelines for installation � � � � � � � � � � � � � � � � � � � � � � � 5
3 Installation plan� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 6
3.1 Correct installation plan . . . . . . . . . . . . . . . . . . . . . . . . .6
3.2 Incorrect installation plan. . . . . . . . . . . . . . . . . . . . . . . .7
3.3 Repeater units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
4 Installation� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 9
4.1 Preparing to add devices. . . . . . . . . . . . . . . . . . . . . . . 11
4.2 Initial settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4.3 Start up the installation menu . . . . . . . . . . . . . . . . . 12
4.4 Creating rooms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.5 Adding mains powered devices . . . . . . . . . . . . . . . . 14
4.6 Adding service devices - mains powered . . . . . . . 14
4.7 Adding room devices - mains powered. . . . . . . . . 15
4.8 Adding room devices - battery powered . . . . . . . 17
4.9 Performing network test . . . . . . . . . . . . . . . . . . . . . . . 17
4.10 Finalising the installation . . . . . . . . . . . . . . . . . . . . . . 19

DEVIlink™ CC
3Installation Guide
5 Modifying an existing installation� � � � � � � � � � � � � � � 19
5.1 Adding devices to an existing room . . . . . . . . . . . . 19
5.2 Changing parameters for heat regulations . . . . . 21
5.3 Removing a room or a service device. . . . . . . . . . . 23
5.4 Factory reset of DEVIlink™ CC . . . . . . . . . . . . . . . . . . 24
6 Wi-Fi and App connection� � � � � � � � � � � � � � � � � � � � � � � 24
6.1 Connect to Wi-Fi. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6.2 Connect to App. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
6.3 Edit connected devices . . . . . . . . . . . . . . . . . . . . . . . . 26
7 Upgrading software version � � � � � � � � � � � � � � � � � � � � 27
8 Warnings� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 29
8.1 Alert Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
9 Technical specications and approvals � � � � � � � � � � 31
10 Warranty� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 33
11 Disposal instructions � � � � � � � � � � � � � � � � � � � � � � � � � � � 33

DEVIlink™ CC
Installation Guide4
1 Introduction
The DEVIlink™ is a programmable,
wireless control system for heating
systems in residential buildings (up
to approximately 300 m2).
The DEVIlink™ CC is the central
control unit. It has a colour touch
screen from where the entire
installation can be controlled.
This installation guide contains all information about the
DEVIlink™ CC and how to get started.
It guides you through recommendations and considera-
tions that must be taken into account when handling a
wireless system - and it describes the conguration of the
system, to ensure a correct and reliable system set-up.
!
Individual instructions, supplied with the service and
room devices, contain information about connecting
the respective devices to the network. The instruction
will also state whether the device is considered a service device or
a room device.
The
?
key can be used at any point during installation.
Always look for the latest software version at www.DEVI.com
before installation. See "7 Upgrading software version".

DEVIlink™ CC
5Installation Guide
2 Guidelines for installation
The signal strength is sucient for most applications,
however, wireless signals are weakened on the way from
the DEVIlink™ CC to the room devices and every building
has dierent obstacles.
Ensure the best performance by keeping the following in
mind for planning and installation:
• Max. 30 m between devices in free space.
• Receiving devices should be placed on opposite or
next wall as the transmitter, if possible.
• All metal objects in the building construction can
weaken wireless signals.
• Reinforced concrete walls and oors weaken the
signal strength signicantly, but almost any types
of construction materials reduce the signal to some
degree.
• Corners that are a result of the building design, can
weaken the wireless signals, due to either long dis-
tances or inadequate reecting opportunities.
Note! These are guidelines only as many factors have inu-
ence on wireless communication.

DEVIlink™ CC
Installation Guide6
3 Installation plan
DEVI recommends that an installation plan is made
before beginning the actual installation.
1. Create an installation plan of all the room devices
(mains powered and battery powered).
2. Add the DEVIlink™ CC in a central location to the
installation plan.
3. Add necessary repeater units (if any) to the installation
plan. DEVI recommends that you include at least one
repeater unit within 5 meters from the CC.
3�1 Correct installation plan
• No metal objects between the DEVIlink™ CC and other
wireless DEVI units.
• The DEVIlink™ CC is installed as central as possible on the
oor plan (max. 30 m between devices in free space).
• Wireless signal through walls on shortest possible
diagonal distance.
!
RS Sensor
(room device) DEVIlink™ HC
(service device)
DEVIlink™ CC
living connect
(room device)
living connect
(room device)

DEVIlink™ CC
7Installation Guide
• No metal objects between the DEVIlink™ CC and other
wireless DEVI units.
• The DEVIlink™ CC is installed as central as possible on the
oor plan (max. 30 m between devices in free space).
• Wireless signal through walls on shortest possible
diagonal distance.
RS Sensor
(room device) DEVIlink™ HC
(service device)
DEVIlink™ CC
living connect
(room device)
living connect
(room device)
3�2 Incorrect installation plan
• Metal objects between the DEVIlink™ CC and other
wireless DEVI units.
• Decentral installation of the DEVIlink™ CC.
• Crossing walls diagonally.
!
!!
RS Sensor
(room device) DEVIlink™ HC
(service device)
DEVIlink™ CC
living connect
(room device)
living connect
(room device)

DEVIlink™ CC
Installation Guide8
3�3 Repeater units
A repeater unit strengthens the wireless signal when a
satisfying connection can not be established between
the DEVIlink™ CC and other wireless DEVI mains powered
devices.
Repeater units can be ordered on stock code no. 140F1138.
Placing repeater units
Plan view, single oor building
CC - central controller
FT - oor thermostat (room device)
HC - hydronic controller (service device)
RS - room sensor (room device)
RU - repeater unit (service device)
living connect - radiator thermostat (room device)
RS FT
FT
CC
RU
HC
living connect
living connect
FT
RS
RS
RS

DEVIlink™ CC
9Installation Guide
Cross section view - building with more than one oor
4 Installation
DEVIlink™ CC can be installed with either a PSU (in-wall
power supply) or a NSU (net power supply).
CC
RS
RS
RU
FT
FT
!
Do not
install in
bathrooms
Avoid direct sun
light onto the
DEVIlink™ CC
Install in
height of
140 - 170 cm

DEVIlink™ CC
Installation Guide10
Mounting the DEVIlink™ CC with In-Wall PSU
• Hold the PSU over the wall box and
mark up the 4 screw holes. Make
sure the top is level.
• Drill holes and insert tting plugs.
• Connect the PSU according to the
connection diagram on the back
side.
• Mount the PSU with the 4 screws.
• Do not connect the DEVIlink™ CC yet!
Mounting the DEVIlink™ CC with NSU
• Place the mounting plate on the wall and mark up the
4 screw holes. Make sure the top is level.
• Drill holes and insert tting
plugs.
• Fasten the mounting plate
with the 4 screws.
• Do not connect the
DEVIlink™CC yet!
• Connect the NSU to a power outlet.
PSU
UP
UP
NSU