Detex VALUE SERIES V40 x EB Manuel utilisateur

FV40 / V40 x EB, EH, EHxR, EX
P/N: 100482
P/N: 100088
Mortise
Strike Shim
98 Strike *, P/N: 100855-1
P/N: 100480
P/N: 100234-1
Mortise Strike
Strike Shield
P/N: 101899
P/N: 100212
2" Narrow Stile
Plastic Template
P/N: 100481
101275 Page 1
Fillerplate SubAssembly (EX x CD)
Owner's Copy
P/N: 104356-1 (3-0)
P/N: 100783
Hex Nut
P/N: 101815-X (4-0)
P/N: 101810-X (3-0)
Pushpad Wrap
Fillerplate SubAssembly
RIM
99 Strike *, P/N: 100855-2
P/N: 101805-1
Centercase Cover
Mounting plate
Subassembly
P/N: 100696-1
Strike ShimNon-Roller Strike
Standard
Plastic Template
P/N: 104350-X
Plastic Template
Centercase/Pushpad SubAssembly
Use for ease of installation
Parts Check List
Fillerplate SubAssembly (EX x HD)
(Electrified Models)
Fillerplate Subassembly (EX x LD)
Fillerplate SubAssembly
P/N: 104358-X
P/N: 104357-1 (3-0)
P/N: 104355-1 (3-0)
P/N: 100783
P/N: PP-5567
Hex Nut
9V Battery
Hex Key
P/N: 100450
Endcap Bracket
U.S. PATENT NUMBERS:
6009732
6205825B1
6532777B2
INTERNATIONAL PATENT NUMBER:
PCT6009732
P/N: 101844
P/N: 101822
Endcap
P/N: 101821
INSTALLATION INSTRUCTIONS FOR DETEX VALUE SERIES® V40 RIM PANIC HARDWARE,
FV40 RIM FIRE EXIT HARDWARE AND "H" MODELS (HURRICANE)
Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045
(830)629-2900 / 1-800-729-3839 / Fax (830)620-6711
E-MAIL: detex@detex.com INTERNET: www.detex.com
101275 November 09, 2007
-GlassBeadKit
-SexNuts
-TamperKit
- Double Door Strike Kit
-KeyStopKit
- Narrow Stile Kit
See
Optional Accessories
For:
Mortise cylinder not included with device.
Standard Yale type cam required.
Note: Parts listed above will vary
according to product configuration.
*Narrow Stile "NS" option
Latchbolt Monitoring
Centercase Assembly
P/N: 104354
P/N: 104357-3 (4-0)
P/N: 104355-3 (4-0)
P/N: 104356-3 (4-0)
L9 = Less 9v Battery
SI = Status Indicator "ON"

frame engages at
Minimum door stile 2" (51mm)
RHR Door
Inside Face
C
L
Floor
Finished
40"
101275 Page 2
RHR Door
Reference
Stop Face
Horizontal
LHR Door
Inside Face
LHR Door
Face
Mullion
Door Must Not Bind
NOTE: 750mm MAXIMUM DOOR WIDTH OPENING FOR EUROPE FOR 36" DEVICE
(1000mm MAXIMUM DOOR WIDTH OPENING FOR EUROPE FOR 48" DEVICE)
THE SAFETY FEATURES OF THIS PRODUCT ARE ESSENTIAL TO ITS COMPLIANCE WITH EN 1125.
NO MODIFICATION OF ANY KIND, OTHER THAN THOSE DESCRIBED IN THESE INSTRUCTIONS ARE PERMITTED.
X
Door Must Swing Freely Door Must Not be Warped
Surface strike possible
Mortise strike recommended
least (3) screw
threads.
Door Must Not Sag
X
Door Skin
X
Blind Rivet Nut
X
Doors and frames with walls having a structural thickness (metal skin
plus reinforcement, or solid wood) to engage less than (3) full
screw threads, are considered unreinforced for hardware.
!!!CHECK BEFORE STARTING!!!
Unreinforced Doors: Use Sex Nuts and Bolts
Fasteners for unreinforced openings are not supplied by Detex.
Unreinforced Frames: Use Blind Rivet Nuts (see sketch)
Minimum door stile 4-1/2" (114 mm)
Wide Stile (Surface Strike)
Template drawings provide door and frame
door and frame preparation.
structural and dimensional specifications for
Narrow Stile
Reinforced door or Reinforcement

(2) Mortise Cylinder NOT Provided.
Note: (1) Fastener selection will vary per catalog configuration and kits ordered.
PPH
PPH
PFH
PFH
PFH
PPH
PFH
Screw Driver
Safety Glasses
Level
Sex Nut
#1/4-20
#10-32
Power Drill
Sheetmetal Screws
#1/4-20 x 1"
#6 x 1"
#10 x 1"
#1/4-20 x 1/4"
#10-24 x 5/8"
#6-32 x 3/8"
#14 x 1"
Center Punch
101275 Page 3
Tape Measure
Hammer
Hack Saw
Used on Strike, Mounting plate, and Endcap Mounting Holes
Used on Strike, Mounting plate, and Endcap Mounting Holes
Recommended on Fire Rated Wood and
9/32" Interior Door Face -----
----
13/64" Interior Door Face
5/16" Exterior Door Face
3/8" Exterior Door Face
-----
-----
-----
Pencil
Tools Required
----
----
----
Used on Strike Hook Mounting Holes
Unreinforced Hollow Metal Doors
Unreinforced Hollow Metal Doors
Recommended on Fire Rated Wood and
Used on Mounting plate and Endcap Mounting Holes
#7 or 13/64"
9/64"
-----
#25 or 9/64"
-----
-----
-----
-----
-----
#10-24 Tap
#1/4-20 Tap
-----
Metal Applications
Used on 99 Strike Center Mounting Hole
Used to Mount Centercase Cover and Endcap
Used to Fasten Centercase Unit onto Mounting plate
Used on 99 Strike Center Mounting Hole
Used on 98 Strike Shield Mounting Holes
PFH
#6-32 x 5/8"
Machine Screws
Fastener Table
Drill Bit Tap Wrench
#36 or 7/64 #6-32 Tap
Comments
Use Either Machine Screws, Sheetmetal Screws,
Used on 98 Strike Shield Mounting Holes
or Sex Nuts
Self-drilling Screws
No pilot hole necessary for
self-drilling screws

101275 Page 4
Strike holes (2)
For 1/4-20 machine screws
drill #7 holes
No pilot hole necessary
for #14 self-drilling screws
(see fastener table)
screws or #14
Fasten tightly with
1/4-20x1" machine
lockwashers and
self-drilling screws
Mark centerline
finished floor
40 inches above
for unit
two 1/4-20x1" machine
screws or #14
self-drilling screws
Fasten loosely with
6
label temporarily
if necessary.
(see outside
trim instructions)
Trim input hole
5
Slide99strikelocator
into mounting plate.
(ifusinga98strike,see
98 STRIKE INSTALLATION page)
1
holes
Mounting plate holes (2)
For 1/4-20 machine screws drill #7 holes.
For #14 self-drilling screws no pilot holes
necessary.
For sex nuts drill 3/8" holes.
(see fastener table)
and strike holes
Mark mounting plate
4
Punch marked
Mounting plate Hole
Strike holes
to mark trim hole
2
Mounting plate
hole
If necessary, remove
3
RECOMMENDED

101275 Page 5
When using Pushpad Wrap with text
(LHR handing shown)
verify handing before installing wrap.
Peel off backing
to expose tape.
IMPORTANT:
Install Pushpad Wrap.
by snapping in place.
Verify wrap is secured
3
Position cam as shown
Insert centercase into slots
of centercase mounting plate,
depress pushpad, rotate
toward door.
1
MUST BE INSTALLED!
to mounting plate
Fasten rim device
with 1/4-20 x 1/4" PPH
2
DOOR

2
1
101275 Page 6
(Call factory at (800) 729-3839 for assistance)
(Cut-Off procedure if required)
CHECKING FOR DEVICE CLEARANCE
onto extrusion
Slide endcap assembly
Secure
Protect wires
during cutting
Place battery in endcap.
Battery should not contact
circuit board.
Battery
4" 10"
Max. Cut-Off
Length (L) inches
beyond edge of cut fillerplate.
Reassemble electronics
Electronics may extend
36" Unit
after cutting.
48" Unit
longer than the standard
REMOVE battery clip
for CUT-OFF lengths
Procedures for Maximum Cut Down Lengths
REMOVE electronics
prior to cut down
34
Caution Required-Special Handling
1
with
tape
Align fillerplate
FLUSH to extrusion
prior to cutting
CAUTION:
Check for device & door
frame clearance. If no
cut-off needed, proceed to
MORTISE CYLINDER INSTALLATION
Cut fillerplate & extrusion to
desired length*
Install battery
(where required)
3
EX
Electrified
model
Cut fillerplate & extrusion to
desired length*
Protect wires
during cutting
6in
2in
12 in
8in
Secure
with
tape
2
36" Unit
Type 48" Unit
Length
Align fillerplate
prior to cutting
FLUSH to extrusion
5
cut-off length

101275 Page 7
cylinder with
Install mortise
hex nut provided
the fillerplate
subassembly
Slide/remove
NOTE:
installing slide in fillerplate.
(2) Turn key max CCW before
(3)Useacylindercollarwheninstalling
(4) Reinstall fillerplate subassembly
(1) All cylinder spacers must be used.
a 7-pin mortise cylinder.
and cylinder collar (not included)
length with spacers (provided)
Adjust for LONGER cylinder
Be careful when installing fillerplate assembly not to damage cable
MORTISE CYLINDER INSTALLATION
PRECAUTIONARY NOTE:
See View A
1
Longer cylinder
Cylinder collar optional
(see note 3)
(Detex p/n: ECL-1595)
2
CAUTION:
Tighten with hand
tools only. Do not
overtighten
View A
Install cable assembly
For Latch Bolt Monitoring (LBM) units only
Refer to switch options pages

101275 Page 8
for added security
Slide and mount endcap
to endcap bracket with two
1/4-20x1" PPH machine screws
or #14 self-drilling screws.
DO NOT OVERTIGHTEN
5
Slide fillerplate & endcap bracket into
extrusion & level pushpad assembly.
Note: Endcap Bracket must bottom-out
on extrusion. DO NOT REMOVE
NYLON SPACER ON BACK OF
BRACKET!
see HARDWIRE TRANSFER OPTIONS page
For 1/4-20 machine screws drill #7 holes.
For #14 self-drilling screws no pilot holes
necessary.
For sex nuts drill 3/8" holes.
Install (2) 6-32 FH Screws
IMPORTANT:
4
With pushpad assembly level,
secure the endcap bracket to door
by tightening the factory installed
self-drilling screw.
3
12

101275 Page 9
extend its life.
Care and Maintenance:
The Detex Value Series® devices are designed to provide many years of maintenance
free service under normal usage. Periodically inspect and lubricate the unit to with hand tools only.
Install cover with 6-32
machine screws. Tighten
4
Fasten rim device to mounting
plate and door with 1/4-20x1"
machine screws(drill #7 holes)
or #14 self-drilling screws
center screw.
strike engagement BEFORE
Align the 99 strike with
Firmly tighten screws
the latchbolt.
marking and drilling for
Check device function and
(use shim if necessary)
3
Note:
2
Mark and drill center hole.
9/64" for 10-24 machine
screws.
No pilot hole necessary
for #10 self-drilling screws.
(see fastener table)
Secure the 99 strike.
Deadlatch
99 strike
For Hurricane Models
(see Hurricane kit)
1

4
N.O. contactViolet
BrownPin 1 Common Pin 4
Contacts rated at 1.0A @ 30VDC or 0.5A @ 125VAC
Pin 5
Pin 6
Normally Closed
Yellow
Gray-Green
Pin 2
Pin 3
Normally Open N.O. contact
101275 Page 10
Violet
---- ----
Figure 3
P1 detail
1
25
36
P1 (see Fig. 3)
Figure 2
Battery Connector
(Standard)
(P1 wire usage)
Wiring Detail
Remote Signal
Table 5
(EHxR)
Bypass/Remote Signal
P2
J2
Remote Bypass
The device flashes one red LED and one beep about every 45 seconds
The Device gives no indication of battery being low.
On
Off (factory set)
J1
Protect wires
Switch selections must be made before applying power or installing battery (See Figure 1)
Table 2
See
See Table 1
Alarm sounds until turned off with key.
Unit sounds alarm as long as door is open.
Extended bypass is enabled.
Alarm turns off 2 minutes after door is closed
Auto Rearming Feature Setting
Status Description
Note: AC power must be applied
Table 3 (EH models only)
Disable Auto rearm
On (factory set)
Off
Disable Low Battery
Table 2
Status Description
The Device gives no indication of armed or disarmed status.
Status Indicator
On
Off (factory set)
SWITCH OPTIONS
Table 1
Disable
AUTOREARM
DisLo Bat
ON
ON
ON
INDICATOR
STATUS
Brown Common
Open
Closed
Yellow
Gray-Green
Install armored cable kit (if required)
V40 x EX Wiring Assembly
Fillerplate subassembly
Wire Color Connection
Endcap bracket
Endcap
(see Table 5)
Figure 1
See Table 3
(jumper w/L9)
TheDeviceflashesredorgreenLEDevery3seconds.
Red indicates armed status and green indicates disarmed.
12/24V AC/DC External Supply
(black wire)
Ce manuel convient aux modèles suivants
4
Table des matières
Autres manuels Detex Système de sécurité
Manuels Système de sécurité populaires d'autres marques

EDM
EDM Solution 6+6 Wireless-AE Manuel utilisateur

Highway Safety Group
Highway Safety Group EA401 Manuel utilisateur

Siren
Siren LED GSM Manuel utilisateur

Detection Systems
Detection Systems 7090i Instructions de montage

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manuel utilisateur

Siemens
Siemens FDM273 Manuel utilisateur