DeTech2OneGateWL REV.D 10/04/19
6 Programming and calibrations
DIP 1 Pos ON LED Off disabled
displaying
DIP 2 Pos ON seismic mode is on
DIP 3 Pos ON
Roller impulses calibration
DIP 4Pos ON Antirip mode is on
Default: DIP in Pos OFF
6.1 LED OFF
DIP 1 PosON
If you want to disable the LED displaying,
set the DIP 1 on ON and close the
cover,the leds will go off in 2 minutes, to
verify the right functioning of the sensor.
6.2 Seismic calibration
The sensor has its calibrated sensitività by
default.If you want to change it, follow these steps
position the DIP on OFF. Push the Tamper key and position
the DIP 2 on ON, release the Tamper and wait fot the GREEN
LED to turn on. This confirms the system is now in
calibration mode. Hit the frame or the window 10 times
(you choose the intensity you need). Every hit the system
acquires will be confirmed by the blinking of the GREEN LED.
The sensor sets the new sensitivity limits, based on the average
hit, for the alarm condition. The calibration will end when the LEDs will
blink alternately, otherwise the previous limits will stay put. To restore
the initioal sensitivity, enter the calibration mode and push the Tamper
key.
6.3CV Rapid contact (Roller)
Connect the roller between the clamp (-) and (CV-IN); the alarm is
reported on the CV-OUT output. It’s possible to change the
number of impulses through the following procedure: while
pushing theb Tamper, set the DIP3 on ON; the leds will blink to
show the system is in programming mode. Release the Tamper and
generate the number of impulses you want: at every impulse, the
GREEN LED will blink to confirm the right acquisition of the
impulses. Position, now, the DIP3 on OFF
6.4Antirip
DIP 4 Pos On
Any attempt of removal from its position, will generate a Sabotage
alarm.
ADDITIONAL INPUTS (NC)
On this clamp, it’s possible to connect an outern contact that will work
in AND with the main contact.
LOW BATTERY report
The low battery report is shown on the sensor through the blinking of
the RED LED.
At the same time, the sensor will send the low battery status to the
DeUnire, on the BATT LOW output.
Change the battery within 15 days.
7BATTERY REPLACEMENT
To replace the battery position the alarm system in MAINTENANCE mode,
open the sensor, remove the battery, push the tamper button repeatedly and
insert the new battery and close back the lid and the eventual door with the
magnet. The sensor will predispose to heating and after the SELF TEST,
afterwards it will be enabled to operative functioning. This will take 2 minutes.
Once the lid is closed, you can exit from MAINTENANCE mode on the board.
8 WARNING:
•explosion danger if the battery isn’t replaced correctly.
Replace it only with an equal or equivalent type.
•In case the battery shows leakage of liquid, change it
immediately. Afterwards, clean your hands if you touched the
fluid.
Warning: Because of its small dimensions, the product can be ingested
easily. Keep away from children.
11 INFORMATION RELATING TO THE DISPOSAL (RAEE GUIDELINE)
•Warning: don’t throw this product in the normal trash bin!
•The electrical and electronical equipment must be managed
separately in accordante with the legislation requiasting the
management, the disposal and recycling of such products
DISPOSAL OF THE BATTERY:
Warning: the battery contains polluting substances, therefore it must
be put in special predisposed to the collecting and disposal of polluting
waste.
The correct disposal of this product will contribute to the right
treatment, recovery and disposal, preventing an eventual negative
impact on the environment and
on human health. Penalties may
be imposed in case of non
compliance of the 151/05
Legislative Decree.