DEMA 606T Manuel utilisateur

DEMA MODELS 606T
INSTALLATION INSTRUCTIONS
I-564 Pg. 1 of 6
Rev. E-41206 11/17/15
I. PARTS:
A. Select-O-Spray Assembly
B. 2 Pcs. Foot Strainers & 1/4" ID Tubing
C. 4 Pcs. Mounting Screws & Anchors
TABLE 1
Hose I.D. 3/8" 1/2" 5/8"
Max. Length 15 ft. 50 ft. 100 ft.
D. 1 Pc. 100-15K Metering Tip Kit
II. INSTALLATION:
A. Mounting and Water Supply.
Mount the unit on a vertical surface using the 4 screws provided through the mounting holes in the cover. The water inlet is
equipped with a female garden hose fitting. The fitting may be removed to permit direct connection to 1/2" NPT pipe.
Water supply pressure should not exceed 125 PSI. Water temperature must not exceed 160 degrees Fahrenheit.
B. Outlet Connection.
Connect the discharge hoses to the outlet garden hose fitting. Spray guns, spray nozzles or foaming wands may be used on
the hose outlets, note that the Select-O-Spray is designed to operate with nozzle flow rates not less than 4 GPM total at 40
PSI. When a spray gun or nozzle is used, hose lengths must not exceed those shown in Table 1. Hoses, spray guns and
foam wands are available through Dema. See the parts list on page 5, under Optional Accessories for various styles.
C. Chemical Supply.
WARNING: USE CARE WHEN HANDLING HAZARDOUS CHEMICALS.
Place the chemical container in a convenient location not more than six feet below the Select-O-Spray. (Greater lifts will
reduce injection capabilities). The top of the container should not be above the Select-O-Spray. Cut the vinyl tubes to any
convenient length that will allow the tubing to reach the bottom of the container. Drop the tubing ends with the strainers into
the chemical containers. Push the other tubing ends over the chemical inlet barbs located on the sides of the unit.
III. FEED RATE ADJUSTMENT:
Model 606T:
The chemical feed rate is controlled by a metering tip screwed into the metering barb on the side of the unit. The feedrates can be
changed by using a different size metering tip, which is available through Dema (See parts list on page 5). To select a proper size
metering tip for the desired dilution ratio refer to Table 2.
IV. OPERATION:
A. Select-O-Spray permits the operator to select one of two chemicals or clear water rinse by opening and closing the
appropriate valve. Only one valve should be opened at any time. If two valves are opened simultaneously, the injector will
not induct chemical. When using a spray gun or foaming wand make sure that the gun on the end of the hose is in the full
open position when inducting chemical.
This product is designed only to be used as described in this instruction sheet. Adhere to all warnings and
cautions identified in this document.
WARNING: Installations must conform to all local and national plumbing codes and use
approved backflow prevention and pressure relief devices where required.
ALWAYS DISCONNECT DISPENSER FROM WATER SOURCE WHEN DISPENSER
IS NOT IN USE.
Always read SDS for all chemicals used and follow personal protective guidelines.

DEMA MODELS 606T
INSTALLATION INSTRUCTIONS
I-564 Pg. 2 of 6
Rev. E-41206 11/17/15
V. SERVICING:
CAUTION: TURN OFF WATER SUPPLY BEFORE SERVICING.
A. If unit fails to draw chemical.
1. Is more than one valve open?
2. Is the hose too long? (See Table #1)
3. Is the gun or nozzle(s) sized properly? (Refer to Section II B). Remove gun and/or nozzle(s) and turn on water. If the
injector inducts chemical, the gun and nozzle(s) are improperly sized.
4. Is the metering tip blocked? Remove tip and clear blockage.
5. Is the hose kinked or otherwise obstructed?
6. Is the spray gun fully open?
B. If unit stops drawing chemical.
1. Is the foot strainer clogged? Lift from drum and clean.
2. Are the spray nozzle(s) partially clogged? Remove and clean.
3. Is the metering tip blocked? Remove and clean.
4. Is the injector check valve clogged? Unscrew the four cover screws to take the Select-O-Spray unit off the wall.
Remove the three ball valve handles to separate the cover from the manifold. Remove the square, plastic metering knobs
to inspect the check valve ball, spring and O-ring.
CAUTION: WHEN SERVICING UNIT BE SURE THAT REPLACEMENT PARTS HAVE BEEN INSTALLED
ACCORDING TO DRAWING. BE CERTAIN CHECK VALVE PARTS ARE IN PLACE.
TABLE 2
SELECT-O-SPRAY DEMA MODEL 606T
METERING TIP SELECTION CHART
FLUID DILUTION RATIOS
METERING TIPS (100-15)
Metering Tip Color
Injection Rate for Viscosities Shown
1 cps 75 cps 200 cps
Oz/Gal Ratio Oz/Gal Ratio Oz/Gal Ratio
Tan 0.40 320-1 0.25 512-1 0.20 640-1
Orange 0.50 256-1 0.35 366-1 0.25 512-1
Turquoise 0.70 183-1 0.50 256-1 0.35 366-1
Pink 0.95 135-1 0.65 197-1 0.45 284-1
Light Blue 1.30 98-1 0.80 160-1 0.55 233-1
Brown 1.50 85-1 0.90 142-1 0.60 213-1
Red 1.90 67-1 1.00 128-1 0.70 183-1
White 2.20 58-1 1.30 98-1 0.80 160-1
Green 2.60 49-1 1.50 85-1 0.90 142-1
Blue 3.20 40-1 1.75 73-1 1.00 128-1
Yellow 4.85 26-1 2.25 57-1 1.10 116-1
Black 6.50 20-1 2.40 53-1 1.15 111-1
Purple 9.20 14-1 2.70 47-1 1.20 107-1
Gray 10.40 12-1 2.85 45-1 1.25 102-1
No Tip 12.80 10-1 3.50 37-1 1.55 83-1
All injection ratios are based on 40 PSI inlet water pressure and a water flow rate of 2.8 GPM.

DEMA MODELS 606T
INSTALLATION INSTRUCTIONS
I-564 Pg. 3 of 6
Rev. E-41206 11/17/15
RETURNS: NO MERCHANDISE MAY BE RETURNED FOR CREDIT WITHOUT DEMA’S WRITTEN
PERMISSION. RETURN MERCHANDISE AUTHORIZATION NUMBER REQUIRED IN
ADVANCE OF RETURN.
WARRANTY: DEMA products are warranted against defective material and workmanship under normal use and service for
one year from the date of manufacture. This limited warranty does not apply to any products which have a
normal life shorter than one year or failure and damage caused by chemicals, corrosion, improper voltage
supply, physical abuse, or misapplication. Rubber and synthetic rubber parts such as “O”- rings, diaphragms,
squeeze tubing and gaskets are considered expendable and are not covered under warranty. This warranty is
extended only to the original buyer of DEMA products. If products are altered or repaired without prior
approval of DEMA, this warranty will be void.
Defective units or parts should be returned to the factory with transportation prepaid. If inspection shows them
to be defective, they will be repaired or replaced without charge, F.O.B. factory. DEMA assumes no liability
for damages. Return merchandise authorization number, to return units for repair or replacement, must be
granted in advance of return.

DEMA MODELS 606T
INSTALLATION INSTRUCTIONS
I-564 Pg. 4 of 6
Rev. E-41206 11/17/15
WATER
INLET
METERING
LOCATION
CLEAR VINYL
SUCTION TUBE
WITH FOOT
STRAINER
WATER/CHEMICAL
SOLUTION OUTLET
(GARDEN HOSE
OUTLET)
CHEMICAL
METERING
LOCATION
TIP
VALVE #1
TIP
RINSE
CLEAR
CHEMICAL
VALVE #2

DEMA MODELS 606T
INSTALLATION INSTRUCTIONS
I-564 Pg. 5 of 6
Rev. E-41206 11/17/15
NO. PART NO. DESCRIPTION
1 66-153 Pipe Plug w/O-Ring
2 65-100-1 Inlet Adapter Stem
3 65-10 Swivel Coupling
4 100-38 Strainer Washer
5 65-2
81-19-20 Ball Valve
Screw for Ball Valve Turn Knob
6 P203CTC Injector (exploded view shown on
separate page)
7 76-2-3 Worm Screw Clamp
8 99-5-11 3/8 NPT Pipe x 5 1/5” Lg.
9 66-99-9 Elbow Hose Barb
10 63-47 3/8 NPT Inlet Adapter
11 65-18-1 3/8 NPT Outlet Adapter
NO. PART NO. DESCRIPTION
12 100-12 Vinyl Tubing ¼”I.D. x 8’ LG
13 61-107-2 Ceramic Weight
14 24-11MP Foot Strainer
15 292QD Foam Wand w/Quick Disconnect
16 40-14QD Heavy Duty Spray Gun w/Quick
Disconnect
17 40-14HD Heavy Duty Spray Gun
18 44-3 Hose (Black) 25’x ½” I.D.
19 44-3RG Hose (Red) Spring Guard 25’x ½” I.D.
20 44-3W Hose (White) 25’x ½” I.D.
21 44-89 Backflow Preventer (A.S.S.E. 1012)
15
16
OPTIONAL ACCESSORIES
17 20
19
18
10
11
13
9
6
8
1
5
7
12
6
2
21
INLET
VENT
14
3
4

DEMA MODELS 606T
INSTALLATION INSTRUCTIONS
I-564 Pg. 6 of 6
Rev. E-41206 11/17/15
NO. PART NO. DESCRIPTION
1 24-67 Screw (4 Req’d.)
2 100-15- Metering Tip (Specify Color)
3 24-62-SP Check Valve Repair Kit
4 24-25S O-Ring
5 24-24P Check Valve Ball
6 24-23-2 Check Valve Spring
7 24-34-7 Check Valve Core
8 25-29S O-Ring
9 24-68 Injector Body (P203C Series)
NO. PART NO. DESCRIPTION
10 100-15K Metering Tip Kit
P
203CTC INJECTOR BREAKDOWN
6
98
7
2
10
4
5
3
1
Table des matières
Autres manuels DEMA Pompe à eau
Manuels Pompe à eau populaires d'autres marques

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guide de dépannage

DUROMAX
DUROMAX XP WX Series Manuel utilisateur

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manuel utilisateur

Franklin Electric
Franklin Electric IPS Manuel utilisateur

Xylem
Xylem e-1532 Series Manuel utilisateur

Milton Roy
Milton Roy PRIMEROYAL Manuel utilisateur