Delta Electronics HEC1200PB Manuel utilisateur

Specification and Manual
Customer :
Description :
Air Conditioner for Equipment (Through Wall Mounting)
Customer Part No : Rev :
Delta Model No :
HEC1200PB
Rev : 02
Sample Date Code:
Sample Issue Date : SEP 15 2020
DELTA ELECTRONICS, INC
252, SHANG YING ROAD, KUEI SAN TEL : 886-(0)3-3591968
TAOYUAN CITY 333, TAIWAN FAX : 886-(0)3-3591991
Please send one copy of this specification back after you
signed approval for production pre-arrangement
Approved by :
Date :

Part no :
Delta model no : HEC1200PB
Page 2
Table of content
Description.......................................................................................................................................... 4
Packing & Shipping ........................................................................................................................... 4
Safety Notes ....................................................................................................................................... 4
1 Product Instruction .................................................................................................................... 8
1-1 General Description .......................................................................................................... 8
1-2 Main Feature & Model Number ....................................................................................... 8
1-3 Dimension ......................................................................................................................... 10
1-4 Mounting Panel Cutout ................................................................................................... 11
1-5 Configuration & Maintenance ........................................................................................ 12
1-6 Thermal and Airflow ........................................................................................................ 13
2 Electrical Specification ........................................................................................................... 14
2-1 Indicator & Connector ..................................................................................................... 14
2-1-1 Power Supply & Alarm Connector ...................................................................... 14
2-1-2 Protection ............................................................................................................... 15
3 Environmental Condition ........................................................................................................ 17
3-1 Operating Temperature .................................................................................................. 17
3-2 Storage Temperature ...................................................................................................... 17
3-3 Operation Humidity ......................................................................................................... 17
3-4 Ingress Protection Rating ............................................................................................... 17
4 Reliability Table ........................................................................................................................ 17
5 Safety Certification .................................................................................................................. 17
6 Accessory ................................................................................................................................. 18
7 Parameters Table .................................................................................................................... 18
7-1 System Setup ................................................................................................................... 18
7-2 Alarm Logs & Fault Processing ..................................................................................... 19
8 Installation Notice .................................................................................................................... 21

Part no :
Delta model no : HEC1200PB
Page 3
9 Reclaim ..................................................................................................................................... 21
10 Versions .................................................................................................................................... 21

Part no :
Delta model no : HEC1200PB
Page 4
Description
This document is an installation and the characteristics of Delta HECX1P series Before installing the
unit, please read this manual thoroughly, and following the instructions contained in it The document is the
exclusive property of Delta Electronics, Inc it should not be distributed, reproduced, or any other format
without prior permission of Delta Specifications are subject to change without notice
Packing & Shipping
During handling or transport, air conditioner must be upward placed, “NO” inverted, flat, excessive
tilt and collision Air conditioner is a precision instrument, it should be handled or transported with care, do
not stand on the box, or place heavy objects on it Please pay attention to the following icons on the
package
If air conditioner is toppled, over slanted or dropped unfortunately, please follow below steps: a stand
for 12 hours to ensure refrigerant pressure stability, b power on and execute self-test to make sure no
alarm happened, c air conditioner keeps 1 hour operating and make sure there is no abnormal acoustic
noise
Safety Notes
Please read the safety notes carefully before installing air conditioning unit and be sure to install it
correctly After completing the installation, make sure that the unit operates properly during the start-up
operation
Meaning of WARNING and CAUTION notices:
Warning:
Failure to follow these instructions properly may result in personal injure or loss life
Caution:
Failure to observe these instructions properly may result in property damage or personal injury,
which may be serious depending on the circumstance

Part no :
Delta model no : HEC1200PB
Page 5
Warning:
1 Installation work and electrical wiring must be done by qualified person(s) in accordance with all
applicable codes, standards and national wiring
regulations
2 Use this unit only in the manner intended by the manufacturer If you have questions, please contact the
manufacturer
3 Install the air conditioner in accordance with the instructions in this installation manual Improper
installation may result in water leakage, electric shocks or fire
4 Make sure that all wiring is secured, the specified wires are used, and there is no strain on the terminal
connections or wires
5 If refrigerant gas leaks during installation, ventilate the area immediately Do not directly touch refrigerant
that has leaked from refrigerant pipes or other areas, as there is a danger of frostbite
6 Before serving or cleaning unit, switch power off and disconnect power supply
7 When cutting or drilling into wall or ceiling, do not damage electrical wiring or hidden utilities
8 Be sure to use only the specified accessories and parts for installation work
9 Protective earth connection: The enclosure must be earthed at the protective earth terminal Use 2 5
mm
2
(14 AWG) wire and use spring washer to avoid loosening
10 The air conditioner shall be not accessible to the general public
11 The installation must contain a device to disconnect all poles of the air conditioner from the power supply
The contact distance in all poles must be 3 mm minimum
12 To reduce the risk of electrical shock Means for disconnection must be incorporated in the fixed wiring in
accordance with the wiring rules
13 This appliance is intended to be used by expert or trained users in shops, in light industry and on farms,
or for commercial use by lay persons”
.
Caution :
1 Install the air conditioner on a wall/ door strong enough to withstand the weight of the unit
2 Do not block air inlets or exits
3 Do not install the air conditioner at any place where there is a danger or flammable gas leakage
4 Arrange the drain to ensure complete drainage

Part no :
Delta model no : HEC1200PB
Page 6
5 To avoid injury, do not touch the air inlet or aluminum fins of unit
6 Watch your steps at the time of fin cleaning or air conditioner inspection
7 Do not topple the air conditioner while moving or storage
8 The hole in the bottom of the air conditioner should be connected to a sealed container through a
drainpipe
9 The appliance is not to be used by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction
10 Children being supervised not to play with the appliance

Part no :
Delta model no : HEC1200PB
Page 7
Specification for Approval
Customer :
Description : Air conditioner for Equipment with 1500 W Rated Cooling Capacity (Through
Wall Mounting)
Customer P/N : Rev :
Delta model no : HEC1200PB Rev : 02
Sample revision : Date Code :
Sample issue date : Quantity : one sets
INTERNAL EXTERNAL

Part no :
Delta model no : HEC1200PB
Page 8
1. Product Instruction
1-1. General Description
HEC1200PB is a DC air conditioner with 48 VDC power input, it is designed for IP55 sealed outdoor
telecom cabinet to provide stable and optimum internal conditions for equipment and avoid hotspot inside
the cabinet
HEC X1
P
B - XXX
(1)
(2)
(3)
(4) (5)
No Item Digit Specification
(1) Product Message HEC Compressor Air Conditioner
(2) Cooling Capacity X1 X1=1200
(3) Operation Voltage P DC 48V for door
(4) Product Version B N/A
(5) Customer ID XXX N/A
1-2. Main Feature & Model Number
Dimensions, Weight & Mounting method
Dimension (H x W x D) (without flange) mm (inch) 700 x 500 x 200 (27 7 x 19 8 x 7 9)
Application Outdoor
Weight Kg (lbs) 28 0 (61 7)
Mounting Method Door/Side
Color (optional) RAL7035
Environmental Protection & Performance
Operating Temperature Range °C (°F) -10 to +55 (+14 to +131)
Operating Humidity External : 0~100% RH
Internal: 0~80% RH
Storage Temperature °C (°F) -40 to +70 (-40 to +158)
Storage Relative Humidity RH 5~95%
Refrigerant R134a, 285 g±10 g
Protection for Dust ,Wind and Water (External)
IEC 60529 /GR487
IP55 / GR487
Noise (1m) dB-A 65
Operating Status N/A LED Indicator / Display Board
Cooling Capacity & Operational Data
Rated Cooling Capacity at L35/L35 W (Btu/hr) 1200 (4080)
Rated Cooling Current A 7 3
Rated Internal Airflow (L35/L35) m
3
/h (CFM) 420 (250)
Rated External Airflow (L35/L35) m
3
/h (CFM) 470 (275)

Part no :
Delta model no : HEC1200PB
Page 9
Power & Range
Input Voltage VDC 48
Max Operating DC Current A 14 3
Alarm N/A Dry Contact Output
Key Components
Controller Built-in Smart Controller
Fans Delta High Efficiency Blowers
Compressor Rotary, DC

Part no :
Delta model no : HEC1200PB
Page 10
1-3. Dimension
mm(inch)
(1) Material: Case SGCC Sheet
(2) Finish: Powder coating 75~120 uM, Color RAL 7035
(3) Dimensional Tolerance: ±1 mm