INSTALLATION
Installation of the cooler must be done according to applicable local codes or equivalent.
Ambient Environment
• Place cooler on an even surface to reduce
vibration and noise.
• To transport, do not tilt the cooler beyond
a 45 degree angle.
• Do not place cooler in direct sunlight or
near any heat sources.
• Do not place cooler in environment
temperatures that exceed 90°F.
• Do not place cooler in below normal
temperatures.
• Do not place cooler in extreme humid
environments, this may cause components
to rust.
• Do not place cooler near constant running
or splattering water, this may cause
immediate damage to refrigeration system.
• Must allow at least 4” between rear of
cooler and wall for proper ventilation and
heat dissipation of cooler.
• Do not place furniture or other articles with
sharp edges near the cooler in order to
prevent damage to the glass door.
• This cooler is for indoor use.
•
there is adequate ventilation in the room.
WARNING: Warranty is void if ventilation
Preparation Prior to Operation
Electrical Requirements
• Remove all packaging materials before
using cooler. This includes: foam pedestal,
protective gaskets.
• Inspect cooler for concealed damage.
carrier if there is damage. Dellcool is not
responsible for damage incurred during
shipping.
• Cooler must remain unplugged in an
upright position for 1 hour prior to use.
• Clean the interior surface with a soft cloth
and lukewarm water before operation.
• Ensure that drain hose or hoses are
positioned in the pan.
• Remove plug and cord from inside the
lower rear of the cooler.
• The unit should be placed close enough
to the electrical supply so that extension
cords are not used.
• This model operates with a 110-120V/60Hz
power supply. Check the electrical outlet
for proper voltage.
• Dedicate one outlet for the use of the
cooler.
• Do not use an extension cord or any other
multiple connectors as this can lead to
compressor failure.
• If the cord is damaged, it must be replaced.
• For your safety, plug the unit into a
grounded wall outlet. Please check with a
WARNING: Do not use extension cords.
WARNING: Compressor warranties are
void if compressor burns out due to low
voltage.
WARNING: Power cord ground pin must
NOT be removed!
MAINTENANCE
Cleaning
• Before cleaning the appliance, always
remember to unplug it.
• Unplug the cooler at the electrical outlet;
never pull the service cord.
• Do not use sharp or pointed objects for
cleaning.
• Clean the inside cabinet of the cooler with
a clean damp cloth. Avoid damage by
using non-abrasive and non- ammable
cleaning products.
• Clean the condenser at least once a
month with a vacuum cleaner or a brush to
eliminate the dust accumulation.
Light Replacement
• Unplug the cooler before removing the
LED light strip.
• Remove the screws.
• Remove the light cover gently.
• Take out the LED light strip.
• Replace the used strip with new equivalent
light strip.
• Install the light cover and tighten the
screws.
• Plug in the cooler.
Power Failure
• Please minimize the frequency of opening
the door during a power failure.
• If your cooler is unused for an extended
period of time, unplug, empty, and clean
your cooler and keep the door open to
avoid condensation, formation of mold, or
odors.
Moving The Cooler
• Empty the unit.
• Secure all loose parts inside the cooler.
• Tape the door shut.
• During transportation, make sure that the
cooler is in an upright position.
Drip Pan
• During normal compressor cycle, water will
drain into the drain pan and evaporate.
• To clean, gently pull the drain pan towards
you and remove. Slowly reinstall it after
cleaning.
LOAD LEVEL
• When loading cooler, do not place product in direct contact with the evaporator fan cover in a
manner that prevents the movement of air. Leave approximately 1” of free space in front of the
Mate series
8 9
Instruction Manual
Dellcool
Place unit in it’s final location,making certain
is insufficient
adhesive tape (used to fix accessories) and
Immediately file a claim with the freight
certified electrician for details.
cover to allow sufficient airflow and proper function of the refrigeration system.