Deister electronic proxSafe maxx Manuel utilisateur

maxx
Wiring & Installation
Instructions
#896097

proxSafe maxx
2
ps_maxx_wi_en
V08/07/09
© Copyright 2008 by deister electronic GmbH
All rights reserved. No part of this publication may be reproduced, stored in a retrieval
system, or transmitted, in any form or by any means, electronic, mechanical, photocopying,
recording, or otherwise, without prior written permission of deister electronic GmbH.
deister electronic GmbH reserves the right to make changes to any and all parts of this
documentation without obligation to notify any person or entity of such changes.
September 2008 CL/IO/BF
deister electronic GmbH
Hermann-Bahlsen Str. 11
30890 Barsinghausen
Germany
Phone: +49 (0) 51 05 - 51 6111
Fax: +49 (0) 51 05 - 51 62 17
E-Mail: info.de@deister.com
Web: www.deister.com

proxSafe maxx
V08/07/09
ps_maxx_wi_en
3
Contents
1. Technical Data ............................................................. 4
2. proxSafe maxx Delivery .............................................. 5
3. proxSafe maxx Installation ......................................... 6
3.1 Installation of proxEntry Reader ......................................................................... 6
3.2 Prepare Terminal for left-side mounting ............................................................. 7
3.3 Open Cabinet................................................................................................. 9
3.4 Mount Terminal to Cabinet ............................................................................ 11
3.5 Operating Cabinet without proxSafe Terminal .................................................. 12
3.5.1 Install Communication Adapter (e.g. SNG3) ............................................... 12
3.5.2 Jumper Setting of Jumper J26.................................................................... 12
3.6 Install Ethernet Adapter .................................................................................. 13
3.6.1 Install DigiConnect Adapter....................................................................... 14
3.6.2 Install USB-Serial-Converter SNG3 ............................................................ 16
3.6.3 Install MOXA N-Port Adapter..................................................................... 17
3.7 Install Power Supply and Back-up Battery ......................................................... 19
3.8 Install/Activate tamper switches....................................................................... 20
3.9 Install further Cabinets ................................................................................... 20
3.10 Mount Cabinet to the Wall ........................................................................... 21
3.11 Close Cabinet............................................................................................. 22
4. Assembling a proxSafe keyRing ............................... 23
5. Commissioning of the proxSafe System.................... 25
5.1 Selftest ......................................................................................................... 25
5.2 Creating an Administrator Card ...................................................................... 26
5.3 Addressing of Cabinets .................................................................................. 27
5.4 Teach-in of keyTags....................................................................................... 28
5.5 Test Operation.............................................................................................. 28
6. Emergency Opening of Roller Shutter ...................... 29
7. Emergency Unlock of proxCylinders ......................... 29
8. Regulatory Notices .................................................... 30

proxSafe maxx
4
ps_maxx_wi_en
V08/07/09
1. Technical Data
Dimensions (mm): 513 x 600 x 210
Housing: sheet metal, powder coated ASA, PC
Weight: approx. 26 kg
Operating temp.: -5...50 °C, for indoor use, non-condensing
Closing force of
roller shutter: max. 30 N
Power supply: 13.8 V/DC, max. 3.0 A, back-up battery in case of power failure
Terminal Interface: RS485/deBUS

proxSafe maxx
V08/07/09
ps_maxx_wi_en
5
2. proxSafe maxx Delivery
Before you start installation of your proxSafe system, please carefully check that you have
received all components that are listed on your delivery note.
The Cabinet package contains:
•the proxSafe cabinet
•2 keys for opening the cabinet
•32 proxSafe keyTags
•32 proxSafe keyRings
•50 pairs of proxSafe one-time seals
•2 cabinet connection cables
Depending on your order, the following components can be part of your delivery:
1) proxSafe Terminal
2) proxSafe power supply
3) SNG3 adapter for USB connection
with power supply
4) TCP/IP adapter for network connection
with cable set
5) proxEntry card reader
6) proxSafe software and manual
7) proxEntry user cards
8) proxSafe desealing tool
1
2
3
4
7
5
8
6

proxSafe maxx
6
ps_maxx_wi_en
V08/07/09
3. proxSafe maxx Installation
3.1 Installation of proxEntry Reader
If your system includes a proxEntry card reader, then this reader has to be installed into
proxSafe terminal:
Attention:
The following instructions are solely intended for installing a reader into a
proxSafe C3 terminal!
1.
Remove the two front screws of the terminal
housing and carefully open the housing.
2.
Remove the two screws of the reader
compartment.
3.
Insert the card reader into the reader
compartment and connect the reader.
4.
Fix the two screws of the reader
compartment.
Please make sure that the reader is mounted in the correct orientation!
Otherwise the three LEDs are hidden in the housing and cannot be seen blinking.
If you want to install the reader on the left-side mounting, please continue with the next chapter.

proxSafe maxx
V08/07/09
ps_maxx_wi_en
7
5.
Close the terminal housing and fix the two
housing screws.
6.
Put the two screw covers in place.
3.2 Prepare Terminal for left-side mounting
The terminal is delivered for mounting on the right side of the cabinet. If you want to mount the
terminal on the left side of the cabinet, you need to prepare the terminal bracket as follows:
1.
Remove the adjusting screw at the curved
slot of the terminal bracket and the second
screw which holds the socket pin. Pull out
the socket pin.
2.
Now carefully pull the two parts of the
terminal bracket apart.
4. 4.

proxSafe maxx
8
ps_maxx_wi_en
V08/07/09
3.
Remove the four screws, which hold the
base plate of the bracket to the back of the
terminal.
5.
Push the second part of the terminal bracket
back into place, insert the socket pin and
tighten it with the according screw and
metal washer.
Now turn the base plate of the terminal
bracket half way around so that the curved
slot is facing towards the left side (when
looking at the front of the terminal) and
tighten the four screws again.
6.
Then tighten the adjusting screw together
with the flexible washer (see picture above).
5.

proxSafe maxx
V08/07/09
ps_maxx_wi_en
9
3.3 Open Cabinet
For the further steps of installation you need to open the proxSafe Cabinet.
1. 2.
You find the key for opening the cabinet
attached to the cabinet.
3.
Carefully move the cabinet insert towards
you. If it is blocked, push the insert into the
frame before opening it.
Slide down the key covering and open the lock.
4.
Unplug the connection cable between the
cabinet insert and the backplane PCB.

proxSafe maxx
10
ps_maxx_wi_en
V08/07/09
5.
Unhook the red safety-wire.
7.
Carefully push open the roller shutter.
6.
Now you can fully remove the cabinet insert.
8.
You can now remove the packages with the
accessories:
-32 keyTags
-32 keyRings
-50 pairs of one-time seals
-2 cabinet connection cables.
Watch out that you do not tear any cables!
Autres manuels pour proxSafe maxx
1
Table des matières
Manuels Sûr populaires d'autres marques

Honeywell
Honeywell 2077D - 1.21 Cubic Foot Anti-Theft Safe Manuel utilisateur

Hornady
Hornady SnapSafe Trunk Safe II Manuel utilisateur

SPORTS AFIELD
SPORTS AFIELD SA-HD5-BIO Manuel utilisateur

Honeywell
Honeywell 5912 Manuel utilisateur

Phoenix
Phoenix FS1280F Manuel utilisateur

Phoenix
Phoenix SS0992K Fiche d'information produit