Deimic One Master Manuel utilisateur

ONE
Master
Installation guide
smart home for everyone

WARNINGS ...................................................................................................................................... 1
1. DEiMiC ONE MASTER DEVICE SPECIFICATION ......................................................................... 3
1.1. DESCRIPTION............................................................................................................................3
1.2. TECHNICAL DATA .....................................................................................................................4
1.3. THE DEVICE PINOUT DESCRIPTION ...........................................................................................5
1.4. APPLICATIONS..........................................................................................................................6
2. ASSEMBLY ................................................................................................................................... 7
2.1. PREPARATION TO ASSEMBLY....................................................................................................7
2.2. GUIDELINES..............................................................................................................................8
2.2.1. WIRES................................................................................................................................8
2.2.2. ELECTRICAL SWITCHGEAR................................................................................................10
2.2.3. CONNECTIONS INSIDE ELECTRICAL SWITCHGEAR.............................................................11
2.2.4. MARKING ........................................................................................................................12
2.2.5. GOOD ADVICES................................................................................................................13
3. EXAMPLES OF WIRING DIAGRAMS......................................................................................... 15
3.1. POWER SUPPLY CONNECTION................................................................................................15
3.2. NETWORK CONNECTION ........................................................................................................16
3.3. OUTPUTS CONNECTION - LIGHTS............................................................................................17
3.4. OUTPUTS CONNECTION –SHUTTERS......................................................................................18
3.5. OUTPUTS CONNECTIONS –GATES, GATEWAYS.......................................................................19
3.6. OUTPUS CONNECTIONS –LED LIGHTS ....................................................................................20
3.7. OUTPUTS CONNECTION –CONTACTORS ................................................................................22
3.8. INPUTS CONNETION –SWITCHES AND BUTTONS....................................................................23
3.9. MOTION SENSORS CONNECTION............................................................................................24
3.10. EXTENSIONS MODULES CONNECTION ..................................................................................25
4. FIRST START .............................................................................................................................. 26
4.1. TEST BUTTON.........................................................................................................................26
4.2. DEiMiC ONE MOBILE APPLICATION.........................................................................................26
4.3. FIRST START OF DEiMiC ONE APPLICATION.............................................................................27
5. GUIDELINES ............................................................................................................................... 28
5.1. ROLLER BLINDS, SHUTTERS AND MARQUISE...........................................................................28
5.2. GATE DRIVES..........................................................................................................................30
5.3. CENTRAL HEATING .................................................................................................................31
6. REVISION HISTORY ................................................................................................................... 33
CONTENS

1Installation guide DEiMiC ONE MASTER v1.8
WARNINGS
This instruction is a part of the product and shall be kept for future reference. Before
installation you should read product documentation, which contains important information
on the device settings and operation.
The module is comply with EU directives, including EMC 2004/108/EC, LVD2006/95/
EC. Declaration of Conformity is available on www.deimic.one.
The producer takes no responsibility for damages caused by inappropriate usage of the
device, inappropriate assembly or not obeying assembly instructions.
The installation must be performed in accordance with every safety standards for electrical
installations and electrical regulations .
The device should be installed by qualified electrician.
Every installation work should be done with power off.
Every repairs must be performed be authorized service only. Device modifications or repairs
done by anyone who is not authorized by the producer are forbidden and means lose of the
warranty.
To avoid risk of electrical shock never open the device and do not touch any
inside components of the device with your hands.
For safety reasons it's necessary to obey all the instructions in this document. Failure to
follow these instructions may result in death or serious injury.
DEiMiC company products are not intended for use in medicine, avionics and industry.
DEiMiC company devices should be installed inside rooms, in places available for a fitter and
conservator.
Remember to ensure proper ventilation for the device and do not expose it to the effects
of weather conditions.
Because of continuing products development, the producer reserves the right to change and
modify the device and its documentation without notice.

2Installation guide DEiMiC ONE MASTER v1.8
RoHS
WARNINGS (continued)
Utilization of waste electrical and electronic equipment is regulated by the EU directive
2002/96/EC. The Directive prohibits disposal of waste electrical and electronic equipment
with other garbage under penalty of a fine.
According to the law, worn out devices must be separately collected and sorted. Customers
should contact their local authorities or the seller to get information about disposal of a
waste electrical and electronic equipment.

3Installation guide DEiMiC ONE MASTER v1.8
1.
DEiMiC ONE MASTER
DEVICE SPECIFICATION
1.1. DESCRIPTION
Figure 1.
DEiMiC ONE MASTER
device
DEiMiC ONE MASTER
device is a base of intelligent building control system. The
device contains 55 inputs (e.g. for switches connections), 36 relay outputs, 4 outputs
dedicated to gates control and 4 dimmable LED outputs. Six of the inputs are dedicated to
motion sensors connections. The device also have two RJ-45 sockets - one for LAN
connection, second for connecting extension modules (
DEiMiC ONE EXPANDER
and
DEiMiC ONE COMFORT
).
DEiMiC ONE COMFORT
module extends the system capabilities by adding
temperature control functionality and increasing number of the system inputs and outputs.
The module includes 22 relay outputs, 8 dimmable LED outputs, 2 relays dedicated to
LEDs power suppliers switching, 32 discrete inputs and 10-channel temperature
controller, which contains a output for a recuperator control and a relay for central heating
furnace switching. Each temperature controller channel includes an analog input for a
temperature sensor connection and a relay output for a heater control.
DEiMiC ONE
EXPANDER module extends system capabilities by increasing number of
the system inputs and outputs. The module includes 64 inputs, 32 relay outputs and 8
dimmable LED outputs. Six of the inputs are dedicated to motion sensors connections.

4 Installation guide DEiMiC ONE MASTER v1.8
1.2. TECHNICAL DATA
Tab. 1. DEiMiC ONE MASTER device parameters
Parameter Value
Number of high-current relay outputs 36
Number of low-current relay outputs (1 A, 250 V AC) 4
Number of dimmable LED outputs (12 V or 24 V) 4
Number of all discrete inputs 55
Number of discrete inputs for motion
sensors connection 6
Number of Ethernet ports 1
Number of USB ports 2
Number of extensions headers 1
Power supply 12 V DC, min. 20 W
Dimensions (length/width/height) 321x109x54 mm
Used space in electric switchgear 18 modules
Installation place Electrical switchgear
Tab. 2. High-current relays maximum load
Load type Max. power
Resistive 2000 W
Fluorescent tube 500 W
Inductive 200 W

5 Installation guide DEiMiC ONE MASTER v1.8
1.3. THE DEVICE PINOUT DESCRIPTION
Figure 2.
DEiMiC ONE MASTER
pinout description
POWER
SUPPLY
LEDS LOW-
CURRENT
OUTPUTS
HIGH-
CURRENT
OUTPUTS
HIGH-
CURRENT
OUTPUTS
INPUTS FOR
MOTION
SENSORS
INPUTS
DISCRETE
INPUTS

6 Installation guide DEiMiC ONE MASTER v1.8
1.4. APPLICATIONS
DEiMiC smart home system provides control of all electrical devices inside
a building such as lights, shutters, car gates and garage gates, heating
devices, alarms, irrigation devices, ventilation and sound systems. The
device is cooperating with motion sensors, temperature sensors and switches.
Thanks to LAN network connection, the
DEiMiC
system can be controlled
via tablet or smartphone, providing the user all information about the
system state from almost every place in the world.
Figure 3. Smart home system with
DEiMiC ONE MASTER

7 Installation guide DEiMiC ONE MASTER v1.8
2. ASSEMBLY
2.1. PREPARATION TO ASSEMBLY
During assembly the following tools may be useful:
phillips screwdriver,
slotted screwdriver,
precision pliers,
flat pliers,
driller,
drill-driver,
nippers for cable cutting,
digital multimeter,
connectors crimper,
cable stripper, soldering
tool.
EVERY INSTALLATION WORK SHOLUD BE
DONE WITH POWER OFF
BEFORE ASSEMBLY, IT IS NECESSARY TO READ THE
INSTRUCTION, ESPECIALLY THE WARNINGS ON PAGE 1
Before assembly it is recommended to prepare a object plane.
Preparation of the object plane and putting there all system devices,
switches and sensors will make easier future work.

8 Installation guide DEiMiC ONE MASTER v1.8
2.2. GUIDELINES
2.2.1. WIRES
1. All standard light sections should be routed from an electrical switchgear
with a 3x1,5mm2 wire or other according to the lamp
producer recommendations.
2. Every roller blinder, marquise, shutter should be routed directly to an
electrical switchgear with 4x1mm2 wire or other according to the
driver producer recommendations.
3. Gate driver should be routed from an electrical switchgear according
to producer specification + UTP cat. 5 cable to the controller.
4. Every motion sensor should be connected with another UTP cat. 5 cable
directly from an electrical switchgear.
5. One UTP cat. 5 cable should be placed between Ethernet router and an
electrical switchgear.
During wires installation it is recommended to ensure appropriate
space between low-voltage wires and mains electricity wires. It is
recommended to avoid situations where signals wires are placed
parallel to the mains electricity wires.
Autres manuels pour One Master
1
Table des matières
Autres manuels Deimic Domotique