Define Instruments Merlin Manuel utilisateur

MER-MAN-14V01 (1002)Copyright © 2014 Dene Instruments
1
Soware
Setup (p9)
Soware
Install (p7)
Hardware
Install (p6)
›Universal input
›22V excitation
›Smart, simple, USB powered setup
›Optional relay outputs
›Optional isolated analogue output
›Designed for harsh environments
›Large 0.8" super-bright display
›Flexible 32 point linearization table
General Description
The Merlin universal digital indicator accepts
analogue inputs from a range of industrial
sensors, including: process, temperature,
ow, frequency, and voltage from 200mV to
300V. It features a wide range power supply
that suits both AC mains and 24V DC appli-
cations, and supplies the excitation required
for common sensors and transmitters.
The Merlin can be scaled into any engineer-
ing unit, and the result displayed on the
large 0.8” 4 digit super-bright LED display.
Auto ranging is available to increase the dy-
namic range of viewable data.
The Merlin R2A adds two Form A 3 Amp
relays for a variety of control and alarm
functions, and a 4-20mA active output for
retransmission to PLCs and SCADA systems.
The unit boasts a 1 minute setup time using
the Dene Toolbox conguration soware.
All functions and features are explained ex-
pertly in the dynamic sidebar help - perfect
for the novice starting out who can use it to
learn about industrial sensors and applica-
tions, or the expert who wants to save com-
missioning time.
The Merlin has been designed for harsh in-
dustrial environments. With NEMA 4X/IP65
sealed bezel and extensive testing of noise
eects to and beyond CE requirements, the
meter provides a tough and reliable applica-
tion solution.
Merlin
Universal Indicator
Quick start
Wiring (p12)

MER-MAN-14V01 (1002) Copyright © 2014 Dene Instruments
2
Contents ................................................. 2
Order Codes ............................................ 2
Safety Notices ......................................... 3
1 - Specications .................................... 3
1.1 - General Meter Specications .... 3
1.2 - Display ....................................... 4
1.3 - Case Dimensions ....................... 5
2 - Hardware Installation ...................... 6
2.1 - Installation Instructions ............ 6
2.2 - Installation Environment .......... 6
3 - Soware Installation ....................... 7
4 - Soware Conguration ................... 9
Using ToolBox
4.1 - Bridge Key ................................. 9
4.2 - Using ToolBox ......................... 10
4.3 - ToolBox Interface Overview ..... 11
5 - Wiring ............................................. 12
5.1 - Wiring Overview ..................... 12
5.2 - EMC Installation Guidelines .... 12
5.3 - Back Panel ............................... 13
5.4 - Power Supply .......................... 13
5.5 - Sensor Input ............................ 14
5.6 - Analogue Output .................... 14
5.7 - Relay Outputs .......................... 14
5.8 - User Input ............................... 14
6 - Input Types ..................................... 15
6.1 - Thermocouple Input ............... 15
6.2 - RTD Input ................................ 16
6.3 - NTC Input ................................ 17
6.4 - Current Input .......................... 18
6.5 - Voltage Input .......................... 19
6.6 - Digital Pulse ............................. 21
6.7 - Potentiometer Input ............... 22
6.8 - AC Current Sensor ................... 23
7 - Maintenance ................................... 24
7.1 - Calibration ............................... 24
7.2 - Troubleshooting ...................... 24
A - Appendix A - EMC Test Results ...... 25
B - Appendix B - Warranty & ............... 27
User's Responsibility
CONTENTS
ORDER CODES
Merlin MER Universal Indicator
Universal Voltage UV 24–250V AC / 19.5–250V DC
Output R2A 2 x relay outputs, 1 x analogue output (4–20mA)
Merlin Universal
Voltage
Output
(Optional)
MER – UV – R2A

MER-MAN-14V01 (1002)Copyright © 2014 Dene Instruments
3
SAFETY NOTICES
For your safety and the prevention of damage to the Merlin unit and other equipment con-
nected to it, please read and carefully observe all safety regulations and instructions. Use
of this instrument in a manner not specied by the manufacturer may compromise the protec-
tion provided by the instrument.
This instrument should not be used to directly drive valves, motors, or other actuators, unless
equipped with appropriate safeguards. It is the responsibility of the user to indentify potential
hazards that may arise in the event of a fault to unit, and implement safeguards for the pre-
vention of harm to persons or equipment.
CAUTION
Risk of electric shock
CAUTION
Risk of danger
For your safety, please read complete instructions prior to installation and operation of
the Merlin. In particular, consult this manual in all cases where hazard symbols are marked
on your Merlin unit, in order to understand and avoid potential hazards. The safety of any
system incorporating this unit is the responsibility of the assembler of the system.
1SPECIFICATIONS
1.1 - General meter specications
Power
Power supply 24–250V AC / 19.5–250V DC,
47–63Hz, 6VA max
Isolation 2,300Vrms for 1min to all inputs
and outputs
Analogue input
Input Universal (see Section 6 for full input
specications and wiring)
Excitation power
Excitation 22V ±10% (25mA max)
Relay output OPTIONAL
Type 2x Form A relays
Isolation to sensor and user input com-
mons 2,300Vrms for 1min
Working voltage 240Vrms
Contact rating
One Relay energized: 3amps @ 120/240V AC
or 28V DC (resistive load)
3amps max total current with both relays
energized
Life expectancy 100K cycles min at full load
rating

MER-MAN-14V01 (1002) Copyright © 2014 Dene Instruments
4
1.2 - Display
Digits 4 digit red LED, 0.8" (20mm),
7-segment characters
Display range -1999 to 9999
Annunciators 2x setpoint indicator
LEDs (R2A model only)
NEMA 4X/IP65 sealed front bezel
User input OPTIONAL
One user input is available on R2A model
only. It can be programmed as a manual
relay reset switch or a latching switch
Max continuous input 20V DC
Isolation to sensor input common
Not isolated
Analogue output OPTIONAL
Type 1x 4–20mA or 20–4mA DC
Isolation to sensor and user input com-
mons 1,400Vrms for 1min
Working voltage 125V
Max output drive 20mA (600Ω max load at
12V DC)
Accuracy/repeatability 0.05% of FSO
Resolution 1μA
Temperature dri 30ppm/°C typical
Powered Self-powered (active)
Environmental conditions
Operating humidity 5–85%RH max
(non-condensing)
Operating temperature -10 to 50°C
Storage temperature -20 to 60°C
Altitude Up to 2,000m
Certications & compliances
EN 61326-1 Immunity to Industrial Locations
Emission CISPR 11 Class A (EN 61326)
Safety requirements for electrical equip-
ment for measurement control, and labora-
tory use:
EN 61010-1 General Requirements
EN 61010-2-030 Particular Requirements
for Testing and Measuring Circuits
NEMA 4X/IP65 Enclosure rating (face only)
Construction
Panel mount enclosure Rated for NEMA
4X/IP65 outdoor use. Installation Category
II, Pollution Degree 2. Flame resistant. Panel
gasket and mounting clips included.
Dimensions 48H x 95W x 62D (mm)
Cutout area 45x92mm ±.5 (1.77x3.62" ±.02)
Space behind panel 80mm (3.15") minimum
space required behind panel (includes space
for connectors/wiring)
Weight 195g (6.87oz)

MER-MAN-14V01 (1002)Copyright © 2014 Dene Instruments
5
1.3 - Case dimensions
95mm (3.74")
107mm (4.21")
91mm (3.58")
80mm (3.15") minimum
depth required behind panel
62mm (2.44")
22mm
(0.87")
4mm (0.16")
48
mm
(1.89")
44
mm
(1.73")
Connectors
& wiring

MER-MAN-14V01 (1002) Copyright © 2014 Dene Instruments
6
2HARDWARE INSTALLATION
2.1 - Installation instructions
The Merlin is designed to be mounted into
an enclosed panel, and meets NEMA 4X/
IP65 requirements when properly installed.
A Prepare the Panel Cutout to 92x45mm
±.5 (3.62x1.77" ±.02) as shown below.
B Remove the Mounting Clips from the
Merlin unit.
C Slide the Panel Gasket over the rear of
the unit to the back of the Bezel.
D From the front of the panel, insert the
Merlin into the Panel Cutout. Holding
the unit in place, engage the Mounting
Clips so that the tabs snap into place
over the notches on the case.
E To achieve a proper seal, tighten the
Screws evenly until the unit sits rmly
against the panel (torque to approxi-
mately 70N-cm [6.2 in-lbs]). Do not over-
tighten the screws.
Panel Bezel
Panel
Gasket
Mounting
Clips
Screws
92mm ±.5
(3.62″ ±.02)
45mm ±.5
(1.77″ ±.02)
Panel Cutout
2.2 - Installation environment
The Merlin should be installed in a location
that does not exceed the maximum operat-
ing temperature, and at a safe distance from
other devices that generate excessive heat.
The installation environment should provide
good air circulation to the unit.
The bezel, plastic casing and product label
may be cleaned, if required, using a so,
damp cloth and neutral soap product.
Continuous exposure to direct sunlight
should be avoided, as this may accelerate
the aging process of the bezel.

MER-MAN-14V01 (1002)Copyright © 2014 Dene Instruments
7
3SOFTWARE INSTALLATION
ToolBox oers a smart, no-fuss setup experience for your Merlin universal indicator. It features
USB powered programming (no power supply required!) and has been designed to simplify
and speed up conguration.
You must install ToolBox before connecting the Merlin to your computer. If you have already
connected the meter using the Bridge Key, please disconnect it before continuing.
A Download the latest version of ToolBox from
www.deneinstruments.com/toolbox
For ease of access, we recommend saving the install le on your desktop. If you cannot locate
the install le, check whether your browser has saved it in your Downloads folder.
B Extract the install le from the zip folder. Right-click on the zip folder and choose 'Extract
All', (or extract the le using another extraction utility of your choice).
C Double-click on the extracted .msi install
le. This will launch the ToolBox installer.
Depending on your security settings, a
'Security Warning' dialogue may appear.
If you see the security message, click
'Run'.

MER-MAN-14V01 (1002) Copyright © 2014 Dene Instruments
8
D The ToolBox setup wizard will
launch.
Click 'Next' to get started.
E The wizard will also ask for
conrmation that you wish
to begin the installation.
Click 'Next' to continue.
F The wizard will prompt you to
select an installation folder.
You may accept the default
installation folder, or select
an alternative location by
clicking 'Browse'.
Click 'Next' to continue.
G The install wizard will now
install ToolBox.
Please wait. This process usu-
ally takes 2-3 minutes, but
may take longer in some
situations.
H When the installation has suc-
cessfully completed, the fol-
lowing dialogue will appear.
Click 'Close' to exit.
The installer will place an icon
on your desktop for easy ac-
cess to ToolBox.
The downloaded .zip and
.msi installer les are no
longer needed, and may be
deleted if desired.

MER-MAN-14V01 (1002)Copyright © 2014 Dene Instruments
9
4SOFTWARE CONFIGURATION USING TOOLBOX
4.1 - Bridge Key
Install the ToolBox soware (see Section 3) before connecting the Merlin to your PC.
Then connect the Merlin to your computer's USB port using the Bridge Key (supplied sepa-
rately), as shown below. The interface cable connects to the USB programming jack on the
unit's back panel (see 5.3D). A USB extension cable is supplied for your use if required - this is
oen used for convenience in accessing USB ports located at the back of the computer.
USB Bridge Key
Interface
Cable
USB Extension Cable
(If Necessary)
PC Connection
INSTALL SOFTWARE FIRST!
Merlin
Universal
Indicator
CAUTION
Risk of damage to equipment or PC
Ensure that all connections between the Bridge Key and your Merlin are secure. Connect-
ing your indicator with cables that are not rmly 'pushed in' will result in connection faults,
and in extreme cases could cause damage to your computer.
Always use the windows ‘Safely remove hardware’ function before unplugging the
Bridge Key from your computer.

MER-MAN-14V01 (1002) Copyright © 2014 Dene Instruments
10
4.2 - Using ToolBox
The ToolBox soware enables full conguration of your Merlin universal indicator. To set up
your indicator, only the Bridge Key is required - you do not need to supply power.
ToolBox features a comprehensive help panel that will guide you through the setup of your
Merlin universal indicator. Helpful hints and explanations will appear when you adjust a
setting using the ToolBox controls.
There are three main navigation pages/tabs:
›Input/Output: Input mode/range, Scaling/offset, Display, Retransmission scaling
›Setpoints: Alarm control/mode, Setpoint activation points, advanced modes
›Advanced: Load/save configuration, Create configuration certificate
A Double-click the ToolBox icon on your desktop to launch the ToolBox program.
B With the Merlin connected to your computer's USB port (see 4.1), click the green
'Connect' button. This will scan your computer's Com ports and automatically connect to
your device.
Connection problems?
ToolBox will auto-detect and connect to the Merlin when you click the 'Connect' button. If you
have problems establishing a connection, please check the following:
›Ensure that all connections between the device and your computer are secure. The main
interface cable must be fully inserted into both the USB programmer and the Merlin's
programming port. Press firmly.
›Try disconnecting and reconnecting the Merlin USB, or using a different USB port on
your computer.
›Disconnect any additional compatible devices. The software auto-detect feature does
not work if multiple Merlins are connected simultaneously.
Autres manuels pour Merlin
1
Table des matières
Autres manuels Define Instruments Écran tactile
Manuels Écran tactile populaires d'autres marques

IBASE Technology
IBASE Technology ASTUT-152-RE1S Manuel utilisateur

YASKAWA
YASKAWA TP 610C Manuel utilisateur

B&R
B&R Power Panel C Series Manuel utilisateur

Beijer Electronics
Beijer Electronics X2 control Manuel utilisateur

AXIOMTEK
AXIOMTEK GOT321W-521 Manuel utilisateur

TRIDONIC.ATCO
TRIDONIC.ATCO x-touchBOX Manuel utilisateur