1. Introduction
Congratulations on choosing a Dennard 2060 Precision Dome camera.
Models covered in this guide include Dennard 2060, Dennard 2060 with drx, Dennard 2060
outdoor, Dennard 2060 outdoor with drx and Dennard 2060 fixed attitude.
This operation manual will provide all the necessary information to install the Dennard 2060
Precision Dome Camera. Please refer to the Menu System manual for operation and programming
features.
2. Index
1. Introduction. 1
2. Index. 1
3. List of contents. 2
4. Mounting configurations. 3
5. Safety bond. 4
6. Standard ceiling mounting. 5
7. Bracket mounting. 6
8. Tile mounting. 7
9. Dome mounting. 8
10. Electrical connections. 9
11. Address switches. 10
12. Control configurations. 11
13. Circuit diagrams. 12
14. Addendum contents. 13
addendum 1. Dennard 2060 fixed attitude dome camera. Addendum 1
addendum 2. Dennard 2060 fixed attitude connections. Addendum 2
addendum 3. Dennard 2060 fixed attitude ‘zoom cam’. Addendum 3

Dennard 2060 Operation Manual Page. 2
3. List of contents
Components supplied
Before installing the dome, please remove the components from the packaging
and verify that all items listed below have been supplied:
1 x Dennard 2060 Dome enclosure (with safety bond)
1 x Power supply
1 x Flying lead connector
1 x Fixing bag containing the following:
1 x 4mm A/F Hexagonal socket key
1 x 5mm A/F Hexagonal socket key (Indoor only)
4 x M6x16 Soc. Cap. Screws (Indoor only)
N.B. Mounting bracketry may have been ordered and delivered separately.
In addition to the above components, the following paperwork is supplied:
A
CD
B
- Dennard 2060 Operation Manual - Dennard 2060 quick setup guide
- Dennard 2060 Menu System Manual - Final test procedure

Dennard 2060 Operation Manual Page. 3
4. Mounting Configurations
With appropriate bracketry the Dennard 2060 dome enclosure can be mounted in any of the
orientations shown above.
1. Wall/Pendant Mount (order code Dennard 90002) giving pendant or wall mount options.
2. Pendant mount bracket (order code Dennard 90003) with drop length to suit customers
requirements.
3. Snowdrop mount bracket (order code Dennard 90004) for mounting at the top of a pole or
column.
4. Vintage mount bracket (order code Dennard 90005) for a vintage feel around historical
buildings.
5. Ceiling mount bracket (order code Dennard 90006) for solid or suspended ceilings.
6. Tile mount (order code Dennard 90001) for suspended ceilings.
7. Corner Bracket (order code Dennard 90007) for mounting to corners of buildings in conjunction
with Dennard 90002.
8. Extended corner bracket (order code Dennard 90008) for mounting to corners of buildings with
Dennard 90002.
9. Extended wall mount (order code Dennard 90009) for extending out from a wall.
All bracket variants can be supplied with optional rain shield (order code Dennard 90010).
All mounting variants are suitable for both weatherproof ( IP66 BS EN 60529 ) & indoor units.
1. 2. 4.
5.
8.
Fig.2 Bracket mounting variants
3.
9.
6.
7.

Dennard 2060 Operation Manual Page. 4
5. Safety Bond
For wall, pendant & snowdrop mounted domes (wall mount shown in Fig.3), clip carbine to the
mounting bracket eyelet (B) on flange of bracket to secure.(shown above).
For standard ceiling mounted domes attach the supplied safety bond, as shown in Fig.4. Fit bond
over M6 stud (position D) and secure with M6 nut, plain washer & spring washer supplied. Clip
carbine to eyelet (E) on dome to secure (see sheet 5 ‘Ceiling mounting instructions’ for details on
eyelet mounting).
Note: Always support dome with bond prior to mating connector (C). Weight of dome should be supported by
bond ensuring no stress is placed on centre connector (C) at any time.
Fig.3 Safety bond (Bracket mount) Fig.4 Safety bond (Ceiling mount)
B
C
E
D
B

Dennard 2060 Operation Manual Page. 5
6. Ceiling Mounting
Cut/drill hole pattern in ceiling as shown in (fig.5) (Note: fixings for hole (A) are not supplied by
Dedicated Micros due to the variation of ceiling materials / thicknesses found on site. Use suitable
M6 fixings, with countersunk head, for your application.) Attach mounting disc (B) to ceiling with
chosen fixings and screw 4 off M6 x 16 soc cap hd. screws supplied into bushes as shown (C).
Attach transfer disc (E) to top of dome enclosure (G) with 4 off M6 dome hd. self tapping trilobular
screws (D) pre-fitted (fig.6) (Note: Fit safety bond bracket (F) as shown) Offer dome enclosure to
ceiling mounting disc (fig.7) engaging the screw heads (C) into keyhole slots (G). Twist to locate
and tighten fixings (C) to secure.
Please ensure safety bond is fitted as descibed on sheet 4.
Fig. 7
Fig.5 Ceiling hole pattern
5mm
B
C
D
E
GDFG
4 x Ø6.5mm
A
Fig. 6

7. Wall Mounting Bracket
A. Remove bracket base casting by unscrewing outer trilobular fixings, then assuming masonry
wall mounting, mark & drill 4 x Ø7 holes using bracket base casting as pattern, shown above.To
assist with orientation flats are provided on all 4 axes allowing the use of a spirit level for
alignment. (Fig 8) (use goggles when drilling).
B. Insert 4 x M6 Rawlplugs into wall until flush.
C. Offer bracket base casting into position & screw wall fixing screws through into inserts.
D. Tighten fixings to secure. Note: An optional spreader plate (9011) is recommended when fixing
to brickwork to reduce the ‘pull out’ forces on a single brick.(Available from Dedicated Micros on
request).
Note: Locating a dome on a corner of a building will give an increased area of surveillance. For this application
Dedicated Micros are able to offer an optional corner bracket (9007) to adapt the standard wall bracket.
E. Thread cable from bracket through cable entry hole in bottom of bracket base casting, then fit
the bracket (Fig 9) (Note: bracket base casting can be orientated to position the entry hole to
either side or at the top.).
F. Using supplied trilobular fixings attach bracket to base casting as shown. (Fig 10).
Dennard 2060 Operation Manual Page. 6
4 x Ø7mm
22.5º
Fig.8 Bracket Base Casting
Fig. 9 Fig. 10
Wall Fixing Screws
E
F
Outer Trilobular Fixings (M6 x 16)

Dennard 2060 Operation Manual Page. 7
8. Tile Mounting
Cut/drill hole pattern in tile as shown in (fig.11).
Attach the mounting disc to the dome as shown in (fig.12) using 3 of the existing M4 dome hd. self
tapping trilobular screws, that attach the hemisphere to the dome (item A).
Offer dome complete with attached mounting disc (item B) up to the hole in the tile from beneath
and clamp to tile using 2 off split clamp rings (items C) from above.
Secure mounting disc with 4 off M6 soc button hd. fixings (supplied) (item D) as shown in (fig.13).
Fit safety bond supplied (item E) to an attachment point in ceiling.
Note: For use with soffit mount the split clamp ring needs to be fixed into position using 4 off M4 pan hd. self
tapping fixings (supplied) (item F) (fig.14).
Fig.14 Split bezel mounting
Fig.11 Ceiling hole pattern
255mm
255mm
4 x Ø7mm
Ø215mm
Fig.12 Mounting disc attachment
A
E
D
F
C
B
Fig.13 Mounting to tile (ceiling)

9. Dome Mounting
Fig.15 Mounting dome to bracket
A. Secure & hang dome to bracket by attaching safety bond carbine to eyelet, as shown.
BMate central connector supplying power & control to dome. (Ensure power is off when
connecting).
C. Lift dome to bracket flange ensuring head of screws (previously fitted M6x16 Trilobular self
tapping screws) pass through keyhole slots. Twist to locate.
D. Tighten 4 top mounting fixings with 4mm A/F Hexagonal key supplied to secure, finally secure
plasic cover to metal pins on bracket flange .
Dennard 2060 Operation Manual Page. 8
B
A
CD