1
A MESSAGE TO OUR CUSTOMERS
We are glad that you selected the Professional Side Burner by DCS. Because this appliance contains features
not found on any other burner, we recommend that you read this entire booklet before your first use. Keep
it in a handy place as it has answers to questions that may occur during future use.
Feel free to contact us if we can help you. When you write please include the model number of the Burner.
We thank you for buying the Made in America Side Burner and wish you many years of enjoyment.
To help serve you better, please fill out and submit your Ownership Registration Card by visiting our website
at www.dcsappliances.com and selecting“Customer Service”on the home page and then select“Ownership
Registration” or submit the enclosed Ownership Registration Card to the address below. In addition, keep
this guide handy, as it will help answer questions that may arise as you use your new appliance.
For your convenience, product questions can be answered by a DCS Customer Service Representative by
or by mail:
DCS
Attention: Customer Service
5800 Skylab Road
Huntington Beach, CA 92647
WARNING
Do not try lighting this appliance without reading the “Lighting Instructions”
section of this manual. Improper installation, adjustment, alteration, service
or maintenance can cause property damage, injury or death. Read the instal-
lation, operating and maintenance instructions thoroughly before use,
installing or servicing this equipment. This outdoor cooking gas appliance is
not intended to be installed in or on recreational vehicles and/or boats.
PRECAUTION
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
FOR YOUR SAFETY
IF YOU SMELL GAS:
Shut off gas to the appliance
Extinguish any open flames.
Open lid.
If odor continues, immediately call your gas supplier.
Installation and service must be performed by a qualified installer, service
agency or the gas supplier.
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE.

TABLE OF CONTENTS
2
SAFETY PRACTICES AND PRECAUTIONS ..................................................................................................3-4
LOCATING THE PROFESSIONAL SIDE BURNER..........................................................................................5
GAS REQUIREMENTS
Natural Gas Hook-up..............................................................................................................................................6
LP Gas Hook-up........................................................................................................................................................7
LP Tank Requirements .......................................................................................................................................... 8
BUILT-IN INSTALLATION FOR MODELS BGA131-BI & BGA132-BI ..............................................9
CART INSTALLATION FOR MODELS BGA131 & BGA132 .................................................................10
LEAK TESTING AND LIGHTING INSTRUCTION
Lighting Instructions ..........................................................................................................................................11
Match Lighting.......................................................................................................................................................12
FINAL CHECKLIST ...........................................................................................................................................................13
GENERAL CLEANING....................................................................................................................................................13
BURNER REMOVAL ........................................................................................................................................................14
TROUBLESHOOTING ....................................................................................................................................................15
PAR TS LIST .....................................................................................................................................................................16-17
WIRING DIAGRAM..........................................................................................................................................................18
WARRAN T Y .........................................................................................................................................................................19
SERVICE ..................................................................................................................................................................................20

3
SAFETY PRACTICES & PRECAUTIONS
Improper use or installation is dangerous. Carefully follow these instructions.
Always remove the cover before lighting the Professional Side Burner. Never use the Side
Burner if a leak is present.
Do not use a flame to check for gas leaks.
Do not let children use the professional Side Burner.
Do not leave children unattended near the Side Burner.
Never let children crawl or hang on the Side Burner.
Exercise care when operating the Professional Side Burner. The burner grate can get hot
enough to cause burns during operation .
Never leave the Side Burner on unattended.
Always wait 5 minutes before relighting the burner to allow any accumulated gas to dissipate.
Should the burner go out during use, turn off the gas valve and wait 5 minutes before
attempting to relight. Always follow the lighting instructions. Never lean over a lit burner.
Never cook without the drip pan in place, pushed all the way to the rear of the burner box.
Use only in well ventilated areas.
Do not use in garages, breezeways, sheds, or other such enclosed areas.
Keep the area surrounding the Professional Side Burner clear and free from combustible
materials, gasoline, other flammable liquids or vapors, charcoal lighter fluid, and trash.
Do not obstruct the flow of combustion and ventilation air to the Professional Side Burner. On
cart mounted units keep area beneath the burner free of debris. If the burner is built-in do not
store gas cylinders beneath the unit without adequate ventilation.
CAUTION:
Do not store items of interest to children above or at the back of any appliance.
Children could be seriously injured if they should climb onto the appliance to
reach these items.
Keep the Professional Side Burner covered when not in use. Never connect an unregulated gas
line to the Professional Side Burner. If the Professional Side Burner has not been used for an
extended period of time (over winter, for example) the unit should be checked for gas leaks and
obstructions in the burner. Thoroughly clean the Professional Side Burner on a regular basis.
Only use the Professional Side Burner with the type of gas specified on the rating plate. To
change from LP gas to natural, or vice versa, a factory conversion kit (See page 6 for conversion
kit information) is required.

SAFETY PRACTICES & PRECAUTIONS
4
SPIDER AND INSECT WARNING!
Spiders and insects can nest in the burner(s) of this or any other gas appliance
and cause the gas to flow from the front of the burner. This is a very dangerous
condition which can cause a fire to occur behind the valve panel, thereby
damaging the unit and making it unsafe to operate.
You must inspect the burner(s) at least once a year or immediately if any of the
following conditions occur:
1. The smell of gas in conjunction with the burner flames appearing yellow.
2. The Professional Side Burner does not reach temperature.
3. The Professional Side Burner heats unevenly.
4. The burner(s) make popping noises.
Do not attempt to disconnect any gas connections while your burner is in use, or the gas supply
is on.
When the Professional Side Burner is stored indoors the gas supply must be disconnected and,
if using an LP gas cylinder, the cylinder must be stored outdoors in a well-ventilated area.
Keep any electrical supply cord away from the heated surfaces of the Professional Side Burner.
On cart mounted units, never move without first allowing the Side Burner and/or grill to cool
and ensuring that the gas supply is turned off. Fold the side shelf down, and push; never pull
the grill.
Never use the Professional Side Burner in a windy area.

5
LOCATING THE SIDE BURNER
1" min.
to combustible
material
1" min.
to combustible
material
1" min.
1" min.
6"
6"
COMBUSTIBLE
CONSTRUCTION
FIG.01
INSTALLATION OF BURNER:
A minimum of 6”from the back and sides must be maintained from the Professional Side Burner above
the cooking surface and a minimum of 1” below the cooking surface to combustible construction.
(Fig. 01)
When determining a suitable location take into account concerns such as exposure to wind, proximity
to traffic paths, and keeping any gas supply lines as short as possible. Locate the Side Burner only in a
well-ventilated area. Never locate the Side Burner in a garage, breezeway, shed, or other such enclosed
areas.
GAS REQUIREMENTS:
Verify the type of gas supply to be used, either natural or LP. Make sure the marked gas on the
appliance rating plate(s) and hook-up kit agrees with that of the supply.
Never connect an unregulated gas line to the appliance.
An installer supplied gas shut-off valve must be installed in an easily accessible location. All installer
supplied parts must conform to local codes, or in the absence of local codes, ANSI/NFPS-770-1984.
All pipe sealants must be an approved type and resistant to the actions of LP gases. Never use pipe
sealant on flare fittings.

GAS REQUIREMENTS
6
All gas connections should be made by a qualified technician and in accordance with local codes and
ordinances. In the absence of local codes, the installation must comply with the National Fuel Gas
Code ANSI Z223.1-1094.
Gas conversion kits are available from the factory. When ordering have the model number, and the
type of gas (natural or LP) which you need.
Total gas consumption of the Professional Side Burner with burner(s) on “HIGH”: Table 1 below.
TABLE 1
The appliance and its individual shut-off valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of 1/2 PSIG (3.5kPa.).
The appliance must be isolated from the gas supply piping system by closing its individual manual
shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or
less than 1/2 PSIG (3.5 kPa.).
The installation of this appliance must conform with local codes or in the absence of local codes, with
the national fuel gas code, ANSI Z223.1a-1987. Installation in Canada must be in accordance with the
Standard Can1-b149 and / or .2 (installation code for gas burning appliances and equipment) and local
codes.
NATURAL GAS HOOK-UP:
CONNECTION: 1/2” NPT male with 3/8” flare adapter.
OPERATING PRESSURE: 4.0”W.C.
SUPPLY PRESSURE: 5” to 14”W.C. if in excess of 14”W.C., a step down regulator is required.
Check with your local gas utility company or with local codes for instructions on installing gas supply
lines. Be sure to check on type and size of run, and how deep to bury the line. If the gas line is too
small, the Professional Side Burner will not function properly.
MODEL Btu/hr
BGA131 15,000
BGA131-BI 15,000
BGA132 30,000
BGA132-BI 30,000

7
GAS REQUIREMENTS
To hook-up the fittings supplied with the
Professional Side Burner, assemble as shown
in Fig.02. Use joint compound on male
threads only.
Do not use joint compound on the flare end of
the 1/2” NPT to 3/8” flare adapter. Ensure that
the regulator arrow points in the direction of
gas flow-towards the unit, away from the
supply.
Do not forget to place the installer-supplied
gas valve in an accessible location.
LP GAS HOOK-UP
CONNECTION: 1/2” NPT male with 3/8” flare
adapter (included).
OPERATING PRESSURE: 10.0”W.C.
Side Burner uses the LP regulator from
adjoining grill.
Apply joint compound to the threaded end of
the Side Burner gas inlet and tighten the
adapter to the pipe. Assemble the (2) 24”
hoses to the 3/8” flare tee, as shown in Fig.03.
Tighten the regulator hose to the remaining
fitting of the 3/8” flare tee.
Open Top
Manifold
Bottom of
131 &132 Burner
1/2" Coupling
1/2" Nipple
1/2" NPT to 3/8"
Flare Adapter
Regulator
To Gas Supply
FIG.02
FIG.03

GAS REQUIREMENTS
8
LP TANK REQUIREMENTS
A dented or rusty LP tank may be hazardous and should be checked by your LP supplier. Never
use a cylinder with a damaged valve.
The LP gas cylinder must be constructed and marked in accordance with the specifications for
LP gas cylinders of the U.S. Department of Transportation (DOT) and designed for use with a
Type 1 system only.
Do not change the regulator/hose assembly from that supplied with the unit or attempt to use
a Type 1 equipped regulator/hose assembly with a standard 510 POL tank/valve assembly. The
cylinder must be provided with a shut-off valve terminating in an LP gas supply cylinder valve
outlet specified, as applicable, for connection Type 1.
If the appliance is stored indoors, the cylinder must be disconnected and removed from the
appliance.
Cylinders must be stored outdoors in a well ventilated area out of the reach of children.
Gas must be turned off when not in use.

9
BUILT-IN INSTALLATION FOR BGA131-BI & BGA132-BI
The Professional Side Burner (BGA131-BI and BGA132-BI) is designed for easy placement into masonry
enclosures. Review the detail drawing below and take into account the provisions shown for the gas
line hook-up clearance in the left rear corner. (Fig. 04)
It is recommended that ventilation holes are provided in the enclosure in the event of a gas leak. The
counter and supporting ledges or deck must be level and flat.
IMPORTANT:
Gas fittings, regulator, and installer shut-off valves must be easily accessible.
22 -1/8"
2
"
25 -
1/2"
10-1/16"
25 - 1/2"
11-
3/4 "
2
"
14
-3/4"
Single Side Burner Dual Side Burner
Standard layout for non-combustible only.
12"
10 - 1/16"
2" X 2" opening
for gas supply line
A
MODEL A
BGA131-BI 12"
BGA132-BI 22-3/4"
10-1/16"
FIG.04
Ce manuel convient aux modèles suivants
3
Table des matières
Autres manuels DCS Brûleur