No. Part Description
7Dual function button switches the fan on and off also used
to confirm
Fan
Enter
8Display the resting and operating time of the steam
generator
Time Display
Window
9Display the detected temperature of steam room
Temp Display
Window
10 Indicator LED for the lamp of steam room
Light LED
11
Indicator LED for water level .Red means water is filling,
green means ideal water level is reached. If the LED is
always in red (exceed 5 minutes). Check water supply and if
water level valve is blocked.Otherwise the water level inlet
valve may be damaged .
Water LED
12 Indicator LED for draining – shows red for manual draining
and green for automatic draining at the end of the cycle.
Drain LED
13 Operation mode indicator red is for steam on demand
mode and green for conventional timing.
Mode LED
14 Green indicates heating is on, red indicates the required
temperature
Heating LED
15 Indicator LED for over heat, red means the steam generator
has been cut off due to heat element being too hot
Overheat LED
16 Indicator LED for fan in operation
Fan LED
17 Indicator LED shows descaling in operation.
When the switch is operated the LED indicator inside the switch turns red and steam is
generated for 30 minutes. At the end of 30 minutes or if the switch is operated again, the
light will go off and the steam will stop. (Notice: Long Press the “Drain/Model” button for
5 seonds, the time display will show ”Long”, then enter “OC-S” mode).
Clean LED
In order for the generator to operate in steam on demand
mode the steam on demand button must be connected.
NOTE
OC-S Steam on Demand Switch
6