Wrong try
penalty
Entry of 4 consecutive invalid codes starts a 5 minute
delay period. LED flashes red at ten (10) second
intervals
At the end of the delay period, two more consecutive
invalid codes will restart an additional 5 minute delay
period
Entry will not respond to a single keystroke during the delay
period
Battery low
warning
Repeated beeping during an opening indicates that the
battery is low and needs immediate replacement. LA
GARD recommends the replacement of batteries at
least once annually.
MANAGER
PROGRAMMING
Add user (feature must be pre-enabled)
Always perform operation with the door
open
1. Enter manager code and HOLD DOWN LAST DIGIT of
Changing the
Battery
3000 AND 3715 KEYPADS Slide the housing
up,
carefully pull
away
from
mounting
surface to
expose
battery
compartment.
CAUTION! Hold
onto battery
terminal to avoid
pulling wires out of
housing.
To replace, carefully
position the keypad
over the mounting
screws and slide the
keypad housing
down. Ensure that
there are no wires or
cables trapped
between the input
code until the lock signals with 2 sets of double beeps
2. Press 1. lock signals twice
3. Enter user code twice.The lock signals twice after
each valid entry
4. if a mistake is made wait thirty (30) seconds and
repeat steps 1-3
VALID CODE ENTRY- double beep after valid six (6)
digits are entered
INVALID CODE ENTRY – Triple beep after six (6)
digits are entered and old code is still valid
Disable user (manager feature only)
1. Enter manager code and HOLD DOWN LAST DIGIT of
code until the lock signals with 2 sets of double beeps
2. PRESS 2. Lock signals once.
3. User is temporarily disabled.
pad and the safe door. Pinched cables can result in a short circuit.
3750 KEYPADS
Remove black plastic battery
compartment cover (located at the
bottom of the keypad) by gently pulling
down on its handle. Allow the battery and
its attached leads to drop down and out
of the battery compartment. If it does not
drop, gently pull at the battery until it
drops out.
When battery is changed gently push the
battery and the leads completely up into
the battery compartment. Install the
battery cover by placing one side of the
cover in position first and then gently
pressing the other side in place.
3035 KEYPADS
Reinstate user (manager feature only)
1. Enter manager code and HOLD DOWN LAST DIGIT of
code until the lock signals with 2 sets of double beeps
2. Press 1. lock signals once
3. User is reinstated
VALID CODE ENTRY- double beep after valid six (6)
digits are entered
INVALID CODE ENTRY – Triple beep after six (6)
digits are entered and old code is still valid
Remove user (manager feature only)
1. Enter manager code and HOLD DOWN LAST DIGIT of
code until the lock signals with 2 sets of double beeps
2. Press 3. lock signals once
User is permanently deleted. Another code can be added if
required via the add user function
VALID CODE ENTRY- double beep after valid six (6)
digits are entered
INVALID CODE ENTRY – Triple beep after six (6)
digits are entered and old code is still valid
If the battery is completely depleted,
place a 9v battery on the ‘snake eyes’ on
the outside of the keypad, hold the
battery there for
the entire
time
while you enter
the
code and open the
lock.
There is a
battery
box located on
the
inside of the safe/cabinet which houses the
battery. Please refer to your cabinet
manufacturer for the exact location. The lid
of the battery box can be lifted and the new battery is placed
inside. Exercise caution with cables, and be careful not to get wires
caught in the battery box when replacing the lid, pinched cables
can result in a short circuit.
CHANGING THE BATTERY- Remove 9-Volt Alkaline battery and
replace with new one. The connector is easily removed by
unsnapping it from the two terminals on the top of the battery.
ONLY USE ALKALINE BATTERIES- we
strongly
recommend the use of
Duracell
Smartlock Digital – a division of Davcor Pty Ltd ABN 95 003 562 598 PH +61-2 9612 4774 Fax +61-2 9612 5774 email sales@smartlockdigital.com