DATATEC Y.I.C. TECHNOLOGIES EMProbe Manuel utilisateur

EMProbe Solution
Comprehensive Setup Guide
Ihr Ansprechpartner /
Your Partner:
dataTec AG
E-Mail: info@datatec.eu
>>> www.datatec.eu

2
Copyright © Y.I.C. Technologies Ltd
All rights reserved.
Sentinel House, Ancells Business Park, Harvest Crescent, Fleet, Hampshire, GU51 2UZ, UK
Disclaimer
Warranty
The material contained within this user manual is provided as is and is subject to being
changed, without notice, in future editions. Further to the maximum extent permitted by
applicable law, Y.I.C. Technologies disclaims all warranties, either expressed or implied, with
regard to this user manual and any information contained herein, including, but not limited to,
the implied warranties of merchantability and fitness for a particular purpose. Y.I.C
Technologies shall not be liable for errors or for incidental or consequential damages in
connection with the furnishing, use, or performance of this document or any information
contained herein. Should Y.I.C. Technologies and the user have a separate written agreement
with warranty terms covering the material in this document that conflict with these terms, the
warranty terms in the separate agreement shall take precedence over those stated herein.
Safety Notices
Caution
A CAUTION notice denotes a hazard. It calls attention to operating procedure, practice, or
similar that, if not correctly performed or adhered to, could result in damage to the product or
loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions
are fully understood and met.
Warning
A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice,
or similar that, if not correctly performed or adhered to, could result in personal injury or death.
Do not proceed beyond a WARNING notice until the indicated conditions are fully understood
and met.

3
Copyright © Y.I.C. Technologies Ltd
All rights reserved.
Sentinel House, Ancells Business Park, Harvest Crescent, Fleet, Hampshire, GU51 2UZ, UK
Components
Box Contents
EMProbe Solution
Magician The robotic arm that will be holding the Near Field
Probes during a scan. 1
Power Supply The power supply for the Magician 1
NFPSet The YIC Technologies Near Field Probe set.
Comes with 5 probes. 1
USB Cable This connects the PC (laptop or desktop) to the
Magician. 1
User-Supplied Components
1. Spectrum Analyzer: This device measures the radio frequency (RF) signal received from
a probe - generated by the very-near-field emissions of an adjacent activated PCB - and
it outputs the data to the PC.
2. PC: A PC running Windows 11 or Windows 10 on an x86-64 processor is required. It is
recommended the PC also meet the minimum system requirements to prevent graphical
bugs, scanning slowdown and crashes.
Minimum System Requirements
Requirements
Operating System: Windows 11 / Windows 10 (latest update)
CPU: 1 GHz or faster with two or more cores, on a compatible 64-bit processor
Memory: 8 GB or more
Storage: 200 MB for installation, and 1 GB for project saves
Graphics card: Compatible with OpenGL 4.2

4
Copyright © Y.I.C. Technologies Ltd
All rights reserved.
Sentinel House, Ancells Business Park, Harvest Crescent, Fleet, Hampshire, GU51 2UZ, UK
Installation and Hardware Setup
To safely and accurately setup the EMProbe solution, please refer closely to the following
information regarding the full installation process.
1. Install communication software for the spectrum analyzer: You must determine
which software to install from the manufacturer’s website. For SCPI controlled spectrum
analyzers, any software which installs NI-VISA can be used. This includes NI MAX,
Keysight Connection Expert and RIGOL UltraSigma. It is recommended to install one of
the following:
a. NI-MAX
Recommended for most SCPI-controlled spectrum analyzers. Download NI System
Configuration from the National Instruments website: www.ni.com. When “Additional items
you may wish to install” is shown, you must have at least NI Measurement & Automation
Explorer selected. Other items do not affect the EMViewer runtime and can be enabled at the
user’s discretion.
b. Keysight Connection Expert
Recommended to use with Keysight spectrum analyzers.
Go to www.keysight.com and search for ‘IO Libraries Suite’, or click here to open the
website to download the latest version. On the website, click on the ‘Download’ button and
follow the steps as instructed.

5
Copyright © Y.I.C. Technologies Ltd
All rights reserved.
Sentinel House, Ancells Business Park, Harvest Crescent, Fleet, Hampshire, GU51 2UZ, UK
c. RIGOL UltraSigma
Recommended to use with RIGOL spectrum analyzers. Some RIGOL analyzers (such as the
RSA5000) require additional downloads to use with this software. Please refer to the user
manual for your spectrum analyzer.
2. Install the EMViewer software application:
You can download the EMViewer software by going to the following linked page:
https://yictechnologies.com/emviewer/
Install the EMViewer software by running the downloaded setup application. The application
should be installed on the C: drive.
A license is required to use the EMViewer software. All licenses are provided by YIC
Technologies. To obtain your license file, please email your PC’s unique hash code (found in
the menu Help->About in the EMViewer software) to support@yictechnologies.com.
3. Setup:
Set up your devices as described in the diagram below.

6
Copyright © Y.I.C. Technologies Ltd
All rights reserved.
Sentinel House, Ancells Business Park, Harvest Crescent, Fleet, Hampshire, GU51 2UZ, UK
EMProbe Connections:
RF Connection: connect the SMA side of the RF Cable to the probe held by the
Magician and the N Type side to the spectrum analyzer (RF Input).
USB Connection: connect the Magician to a PC using the USB cable.
Establish a Connection
After you have connected the Magician to the PC and powered it on, wait at least 30 seconds
for the software to detect it. You will see the EMProbe be detected by the software:
In some cases, the driver required may not be installed automatically. If the EMViewer
software cannot detect the scanner, the driver will need to be installed manually. A copy of the
USB driver can be found on the PC in the following location:
C:\Program Files\YIC Technologies\EMViewer2\drivers\EMProbe
To manually install, copy the EMProbe folder to the desktop. Inside the copied folder, right
click on:
silabser.inf - > Install
You may delete the folder from your desktop once the driver is installed.

7
Copyright © Y.I.C. Technologies Ltd
All rights reserved.
Sentinel House, Ancells Business Park, Harvest Crescent, Fleet, Hampshire, GU51 2UZ, UK
Technical Support
For fast and seamless technical support, please gather the following
information and contact Y.I.C. Technologies technical support as instructed
further below:
1. Serial number of your unit (Shown in the device list).
2. Software version (Menu: Help -> About).
3. Your analyzer control software (e.g. NI-MAX or Keysight Connection Expert)
4. Spectrum Analyzer model and manufacturer (or *IDN)
5. The log file stored in %appdata%/YIC Technologies/EMViewer2/log.txt
6. A detailed description of the problem, including screenshots and video footage.
www.yictechnologies.com
support@yictechnologies.com
Ihr Ansprechpartner /
Your Partner:
dataTec AG
E-Mail: info@datatec.eu
>>> www.datatec.eu
Table des matières
Manuels Équipement de test populaires d'autres marques

SMART
SMART KANAAD SBT XTREME 3G Series Manuel utilisateur

Agilent Technologies
Agilent Technologies BERT Serial Manuel utilisateur

Agilent Technologies
Agilent Technologies N3280A Manuel utilisateur

Vernier
Vernier Go Direct Voltage Manuel utilisateur

Lifeloc
Lifeloc R.A.D.A.R. Manuel utilisateur

Fluke
Fluke T5-600 Instructions d'utilisation et d'installation