HOW TO ARM YOUR SECURITY SYSTEM
To Arm the security system, close all of the protected doors and windows. The green "READY"
light on the code pad control will be illuminated when all of the protected zonesandsensorsare
secure. If any of the zones are isolated, a sensor in that zone can be violated without affecting
the "READY" light. The security system will not arm if the "READY" light is not illuminated.With
the "READY" light on, you may arm the security system with your Master Code or one of the
auxiliary codes. Each time a key is pressed on the code pad control, a short tone (beep) will
sound. If the code pad beeps three times after a code entry, it is an indication that the code has
not been accepted. Press the [#] key (reset) and re-enter a valid code. If the code pad control
beeps continuously after code entry, it is an indication that the "POWER" light is off. The code
pad sounder can be silenced by re-entering your four digit code. If the "POWER"lightisoff,you
should restore power to the system if possible. When the security system has accepted a valid
code, the red "ARMED" light will illuminate indicating that the system has beenturnedon.Ifyou
choose to leave the protected area, you must exit within the exit delay time. If you choose to
stay within the protected area, insure that all interior zones which may be tripped by your
movement are isolated.
HOW TO DISARM YOUR SECURITY SYSTEM
When you enter the protected area through one of the designated entry/exit doors, the code
pad control will sound a continuous tone (beep) for the duration of the entry delay time, oruntil
you enter a valid code. After a valid code has been entered, the red "ARMED" light will turn off,
and the tone will stop. The security system is now DISARMED (off). If a valid code is not
entered before the end of the entry delay time, an alarm will occur. (NOTE: IF THE RED
"ARMED" LIGHT IS FLASHING DURING THE ENTRY DELAY, THE ALARM SYSTEM HAS
BEEN ACTIVATED IN YOUR ABSENCE. LEAVE THE BUILDING IMMEDIATELY AND CALL
YOUR ALARM COMPANY AND/OR THE POLICE.)
ALARM MEMORY
To review the previous alarm, press [0] and wait 5 seconds. The zones that were activated
during the last alarm will flash for 5 seconds. This condition will stay in memory until the next
alarm activation.
HOW TO ISOLATE ZONES
To isolate any of the zones, press [], zone number(s) to be isolated (1 thru 6), and [].Zones
cannot be isolated or de-isolated while the control is armed. When the security system is
disarmed, all isolated zones will be de-isolated. As isolated zones are not protected, this
procedure should only be given to authorized persons. For example, to isolate zone 1, the
sequence would be as follows:
[] - [1] - []
To isolate zones 1, 3, and 4, the sequence would be as follows:
[] - [1] - [3] - [4] - []
QUICK-ARM FEATURE
If this box is checked, your security system will have the [3] key "QUICK ARM" code