To our customers
Attention
1. Before installing the heat pump, please check whether the local power supply corresponds
with the requirement of the heat pump. For details, please refer to the nameplate on the unit
or the installation and operation instruction.
2. Please install the electrical protection devices according to local regulations.
3. Connecting the heat pump to a ground wire is necessary, in order to prevent electric shock
caused by an unexpected short circuit inside the unit.
4. In wire connection, the electrician can refer to the wiring diagram in this manual. Wiring tasks
should be carried out by qualified electricians only. In addition, they should check the safety
conditions of power utilization, for example, check if the cable capacity is adequate, and check
if the power cable is damaged.
5. Do not insert any objects into the heat pump when running. It may touch the fan and damage
it or lead to accidents (especially for the children).
Do not use the unit without the grid in case it may lead to any accidents.
6. For safety reasons, please do not change or repair unit by yourself. If it is necessary, please
contact local distributor for help.
7. If there is something wrong with the unit, contact immediately with local distributor or our
factory. The unit can be reused only after check and solution by the technical staff.
8. Make sure that cut off the electric supply before maintaining the unit.
9. Please follow the instruction below when cleaning the unit.
a. Before cleaning, cut off the electric supply of the unit firstly to avoid injuries caused by fan
in operation.
b. Do not rinse the unit by water because the rinsed unit may cause electric shock.
Note!
Dear customers, thank your for your kind support to our products. Please read this
instruction carefully before the installation and application of this product. The precautions
listed below are all-important for safety. Please follow the instructions strictly.

Swimming pool heat pump
- 2 -
Content
Product brief instruction………………………….…………….……………………………………..3
Technical data....................................................................................................4
Unit dimension………………………………………………………….......................................6
Installation………………………………………………………………........................................8
Electric connection………………………………………………………………..........................14
Controller operation instruction………………..………………………………………………….19
Maintenance & Troubleshooting………………………….…………………………………....…23

Swimming pool heat pump
- 3 -
PRODUCT BRIEF INSTRUCTION
1.1 Performance
High efficiency
With a COP value more than 4.9, our heat pumps are very efficiency when transferring heat from
the air to the swimming pool water. It can save as much as 80% of cost compared to an electric
heater.
Long life‐span
The heat exchanger is made of PVC & Titanium tube, which can withstand and prolong exposure to
swimming pool water.
Easy control and operation
The unit is very easy to operate: simply switch it on and set the desired pool water temperature.
The system includes a remote controller, allowing all operation parameters to be set. Operation
status can be displayed on the controller with LCD display.
1.2 Working principle
Heat pumps utilize the sun’s free heat by collecting and absorbing energy from the outside air.
This energy is then compressed and transferred to the pool water. Your existing water pump
circulates the water through the heat pumps heater, usually next to the pool equipment, and the
water warms up.
This pool heat pump is also of cooling function. User can choose the heating or cooling mode
through the LCD controller. The cooling mode’s working principle is opposite to the heating mode.
●The unit contains a fan that draws in outside air and directs it over the surface of the
evaporator (energy collector). The low temperature refrigerant liquid within the evaporator coil
absorbs the heat from the outside air becomes warm gas.
●The warm gas in the coil pass through the compressor, where the warm gas is concentrated
and increased to hot gas, and then pass to the condenser (water heat exchanger). It is here that
the heat exchange occurs as the hot gas give off heat to the cold swimming pool water circulating
through the coil.
●The pool water becomes warmer, and the hot gas cooling as it flows through the condenser
coil returns to liquid form, after passing on through the capillary tube, the whole process begins
again.

Swimming pool heat pump
- 4 -
TECHNICAL DATA
Swimming pool heat pump
Model DSP‐45HCA DSP‐65HCA DSP‐85HCA DSP‐100HCA DSP‐120HCA
Heating Capacity*
(KW) 4.5 6.5 8.5 10 12
Heating Input (KW) 0.86 1.32 1.55 1.98 2.44
Heating Capacity**
(KW) 5.2 7.6 9.4 11.3 13.5
Heating Input (KW) 0.91 1.35 1.61 2.1 2.49
Cooling Capacity
(KW) (Optional) 3.2 4.7 6 8 9
Cooling Input (KW) 0.94 1.3 1.86 2.2 2.5
Heating Rated
Current (A) 3.9 5.5 7.2 9.36 11.8
Max. Current (A) 5.8 8.6 11.3 15.7 18.2
Power Supply
(V/Ph/Hz) 220~240/1/50
Setting Temp. Range 15℃~45℃
Running Temp.
Range -5℃~43℃
Water Inlet/Outlet
Dimension (mm) 50.8
Water Heat
Exchanger Titanium
Water Flow(m3/h)≥3 ≥4 ≥4 ≥4.5 ≥4.5
Refrigerant R410A
Unit Dimension
W×H×D(mm) 816x306x510 995x350x552 1118×350×617 1140x460x650
Net Weight(KG)39 46 52 62 75
Display LCD
Mode Heating/Cooling (Optional)/AUTO
Housing cover Both Galvanized and Plastic cover are avaliable.
Noise dB(A) 42 42 43 45 45
NOTES:
Capacities and power inputs based on the following conditions:
- Heating* : Outlet water temperature 27℃. Ambient air temperature 24℃(DB)/19℃(WB).
- Heating** : Outlet water temperature 27℃. Ambient air temperature 27℃(DB)/19℃(WB).
- Cooling: Outlet water temperature 27℃. Ambient air temperature 35℃(DB)/24℃(WB)

Swimming pool heat pump
- 5 -
Swimming pool heat pump
Model DSP‐180HCA DSP‐180HCA/3 DSP‐230HCA DSP‐230HCA/3 DSP‐260HCA/3
Heating Capacity*
(KW) 18 23 26
Heating Input (KW) 3.61 4.8 5.21
Heating Capacity**
(KW) 21 26 30
Heating Input (KW) 3.8 4.9 5.4
Cooling Capacity
(KW) (Optional) 13 18 20
Cooling Input (KW) 3.7 5.1 7.4
Heating Rated
Current (A) 16.5 5.6 21 9.06 10.2
Max. Current (A) 24.5 9.7 31 13.9 15.8
Power Supply
(V/Ph/Hz) 220~240/1/50 380~415/3/50 220~240/1/50 380~415/3/50
Setting Temp. Range 15℃~45℃
Running Temp.
Range -5℃~43℃
Water Inlet/Outlet
Dimension(mm) 50.8
Water Heat
Exchanger Titanium
Water Flow(m3/h)≥7.5 ≥8.5
Refrigerant R410A
Unit Dimension
W×H×D(mm) 820X720X1055
Net Weight(KG)119 119 133 133 148
Display LCD
Mode Heating/Cooling (Optional) /AUTO
Housing cover Both Galvanized and Plastic cover are avaliable
Noise dB(A) 52 52 52
Capacities and power inputs based on the following conditions:
- Heating* : Outlet water temperature 27℃. Ambient air temperature 24℃(DB)/19℃(WB).
- Heating** : Outlet water temperature 27℃. Ambient air temperature 27℃(DB)/19℃(WB).
- Cooling: Outlet water temperature 27℃. Ambient air temperature 35℃(DB)/24℃(WB)
Note:
1. The above data might change as the product improves.
2. Cooling function is optional, if you need please claim it in advance.
3. Both Galvanized and Plastic cover are avaliable; default Galvanized panel. If you want the heat
pump with plastic cover, please claim it in advance.

Swimming pool heat pump
- 6 -
UNIT DIMENSIONS
Horizontal models
Model A(mm) B(mm) C(mm) D(mm) E(mm)
DSP-45 HCA 510 306 266 276 410
DSP-65(85) HCA 552 995 284 344 680
DSP-100 HCA 617 1118 350 290 660
DSP-120 HCA 650 1140 415 435 684

Swimming pool heat pump
- 7 -
Vertical models
DSP-180HCA, DSP-180HCA/3,
DSP-230HCA, DSP-230HCA/3
DSP-260HCA/3

Swimming pool heat pump
- 8 -
INSTALLATION
Installation position
1. The unit must be installed on reliable base or framework. Weight capacity of framework
should be 3 times of the body weight, and safeguard measures should be taken to avoid
malfunction of fastenings.
2. If the unit is to be installed on the floor, its undercarriage should be heightened, to avoid
ingression of accumulated water in rainy season. In snowy areas, it is important to prevent
accumulated snow from blocking up the air-out. The recommended height is 20cm to 30cm.
Take the vertical model as an example, see the drawing below.
3. Drain ditch or other facilities should be arranged under the outdoor unit, to avoid the influence
of water discharge.
Note!
Installation must be carried out by professional staff.

Swimming pool heat pump
- 9 -
4. To install the unit at balcony or top of building, the installation site must meet the allowable
bearing capacity of building structure, without affecting the structural safety.
5. Ensure the unit is well ventilated.
Virtually the unit may be installed anywhere outdoors providing minimum distance
requirements are met with respect to other objects.
For indoor pools please consult your installer.
Attention:
Do not place the unit in an enclosed area with a limited air volume where the unit’s discharged
air will be re-circulated or near shrubs that could block the air inlet. These locations deny the
unit a continuous fresh air supply, which reduces its efficiency and may prevent adequate heat
yield.
Model: horizontal unit
Autres manuels pour DSP?45HCA
1
Ce manuel convient aux modèles suivants
9
Table des matières
Autres manuels Daishiba Pompe à chaleur
Manuels Pompe à chaleur populaires d'autres marques

Mitsubishi Electric
Mitsubishi Electric PUZ-SWM60VAA Manuel utilisateur

Dimplex
Dimplex LI 16I-TUR Guide de l'utilisateur

Carrier
Carrier WSHP Open v3 Guide de configuration rapide

TGM
TGM CTV14CN018A Manuel utilisateur

Carrier
Carrier 38MGQ Series Manuel utilisateur

Kokido
Kokido K2O K880BX/EU Guide de dépannage