Alarm seng and cancelling:
You can input a count number you wish to give an audible alarm. First press ‘QTY
PST’ and display shows ‘DOWN’. If you enter a gure (e.g. 10) the alarm will sound
at between 1 and 9. Press ’QTY PST’ again and display shows ’UP’. A gure entered
here (e.g. 20) causes alarm to sound when the count number is 21 or more. These
sengs can be used alone or together allowing target count number to easily be
proved without need to refer to the display.
To cancel the alarm, press " PST CE" to clear both ‘UP’ and ‘DOWN’ entries.
Accumulaon Funcon:
When counng press " M+" key to enter accumulaon mode, and the weight
screen then displays the number of mes it has been pressed. The Total Count
screen displays the accumulated total and then returns to counng mode.
If the total accumulated quanty exceeds the display range, the display will show
" OL ".
During ACCUMULATION mode press "MC " key to clear value of total accumulated
weight.
Select backlight display operaon:
Turn on the scale and during self-checking, press and hold "1" key unl
self-checking nished, indicated by a connuous tone. The current backlight mode
will show in the Weight display. You can select from three modes of operaon,
AUTO, OFF and ON using the ‘TARE’ key, then press ‘ZERO’ to accept the seng.
Weighing unit sengs:
Turn on the scale and during self-checking press and hold "2" key unl self-
checking nished, indicated by a connuous tone. The current weighing unit shows
in the weight display. Select desired unit with ‘TARE’ key and press ‘ZERO’ to
accept. The following entries are for ‘communicaon interface’ facilies unused on
this model, so just press ‘ZERO’ twice to complete unit seng.
County Scales Limited
Page 4