CSA BG-36B Manuel utilisateur

Model# BG-36B
36"L WALL MOUNT/RECESSED ELECTRIC
FIREPLACE- FRONT VENT WITH REMOTE
CONTROL- ORANGE FLAME COLOR
Model# BG-50B
50”L WALL MOUNTED/RECESSED ELECTRIC
FIREPLACE-FRONT VENT WITH REMOTE
CONTROL - ORANGE FLAME COLOR
AC 120V 60Hz 1500W
IMPORTANT SAFETY INFORMATION: Always read this manual first
before attempting to install or use this fireplace. For your safety , always
comply with all warnings and safety instructions contained in this manual
to prevent personal injury or property damage.

2
Table of Contents
Always use a qualified technician or
service agency to repair this fireplace
!NOTE: Procedures and
techniques that are considered
important enough to emphasize.
CAUTION: Procedures and
techniques which, if not carefully
followed, will result in damage to
the equipment.
WARNING: Procedures and
techniques which, if not carefully
followed, will expose the user to
the risk of fire, serious injury , or
death.
IMPORTANT INSTRUCTIONS ..............................
Quick Reference Guide..........................................
Fireplace Installation ...........................................
Wiring Diagram .......................................................................
Hard wire Installation................................................................
3-4
5
6
8
9
Wiring..................................................................................... 9
Front Glass Removal / Installation...................................................10
Wall Mount Installation ..........................................................11-12
Framing.......................................................................................
Fully Recessed Installation............................................................... 14
Partially recessed installation........................................................... 15
Media Installation................................................................................16
Operation............................................................... 17-18
Maintenance....................................................................
20

3
IMPORTANT INSTRUCTIONS
When using electrical appliances,
basic precautions should always
be followed to reduce the risk of
fire, electric shock, and injury to
persons, including the following:
①Read all instructions before
using this electric fireplace
②This fireplace has its heating
vent in the front. The glass area in
the middle slot will get hot when
the heating function is turned on.
To avoid burns, do not let bare
skin touch the hot surface. The
rest of the fireplace including the
tempered glass section will not
get hot.
Middle Slot
DANGER: High temperatures
may be generated under certain
abnormal conditions. Do not
partially or fully cover or obstruct
the front of this heater.
③Extreme caution is
necessary
when any heater is used by
or near children or invalids and
whenever the unit is left operating
and unattended.
④Young children should be
supervised to ensure that they do
not play with the appliance.
⑤The appliance is not intended
for use by young children or
infirm persons without
supervision.
⑥Do no operate any heater
after it malfunctions. Disconnect
power at service panel and
have heater inspected by a
reputable electrician before
reusing.
⑦If the supply cord is damaged
it must be replaced by the
manufacturer, or its service agent,
or a qualified person in order to
avoid a hazard.
⑧Do not use outdoors.
⑨Never locate fireplace where
it may fall into a bathtub or other
water container.
⑩Do not locate the heater
immediately below a fixed
socket outlet.
⑪To disconnect the fireplace
turn the controls off, and turn off
power to heater circuit at main
disconnect panel.
⑫Do not insert or allow foreign
objects to enter any ventilation
or exhaust opening as this may
cause an electric shock or fire,
or damage to the heater.

4
⑬To prevent a possible fire, do
not block air intakes or exhaust
in any manner.
⑭A heater can produce arc
flashes or sparks when electric
current flows. Do not use in
areas where gasoline, paint, or
flammable liquids are used or
stored.
⑮Use this heater only as
described in this manual. Any
other use not recommended by
the manufacturer may cause fire,
electric shock or injury to persons.
⑯To reduce the risk of electric
shock, this appliance has a
polarized plug (one blade is wider
than the other). This plug will fit in
a polarized outlet only one way. If
the plug does not fit fully in the
outlet, reverse the plug. If it still
does not fit, contact a qualified
electrician to install the proper
outlet. Do not change the plug in
any way. Always plug heaters
directly into a wall
outlet/receptacle. Never use with
an extension cord or relocatable
power tap (outlet/ power strip).
⑰Do not burn wood or other
materials in the electric
fireplace
⑱Do not strike the fireplace
glass.
⑲Always use a certified
electrician should new circuits or
outlets be required.
⑳Always use properly grounded,
fused and polarized outlets.
㉑Disconnect all power supply
before performing any cleaning,
maintenance or relocation of the
unit.
㉒When transporting or storing
the unit and cord, keep in a
dry place, free from excessive
vibration and store so as to avoid
damage.
WARNING: Remote control
contains small batteries. Keep away
from children. If swallowed, seek
medical attention immediately.
WARNING: Do not install battery
backwards, charge, put in fire or mix
with used or other battery types - may
explode or leak causing injury.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
NO USER SERVICABLE PARTS INSIDE
SAVE THESE INSTRUCTIONS

5
Quick Reference Guide
①The electrical information regarding your electric fireplace can be found on
the rating label located on the front of the unit, behind the glass.
②For dimensions of your fireplace, refer to below diagram
PRODUCT DIMENSIONS
Model Number
Description
A
B
C
D
BG-36B
36"L WALL MOUNT/RECESSED
ELECTRIC FIREPLACE- FRONT
VENT WITH REMOTE CONTROL-
ORANGE FLAME COLOR
36"
91.5cm
21.46"
54.4cm
5.51"
14cm
32.48"
82.5cm
BG-50B
50"L WALL MOUNT/RECESSED
ELECTRIC FIREPLACE- FRONT
VENT WITH REMOTE CONTROL-
ORANGE FLAME COLOR
50"
128cm
21.46"
54.4cm
5.51"
14cm
46.85"
119cm
PRODUCT DIMENSIONS
Model Number
Description
E
F
G
BG-36B
36"L WALL MOUNT/RECESSED
ELECTRIC FIREPLACE- FRONT VENT
WITH REMOTE CONTROL- ORANGE
FLAME COLOR
20.51"
52.1cm
12"
30.5cm
30.91"
78.5cm
BG-50B
50"L WALL MOUNT/RECESSED
ELECTRIC FIREPLACE- FRONT VENT
WITH REMOTE CONTROL- ORANGE
FLAME COLOR
20.51"
52.1cm
12"
30.5cm
38.31"
97.3cm

6
Fireplace Installation
Site Selection
Review and consider all of the fol-
lowing conditions for installation:
1.Unit requires a minimum of two
wall studs in order to ensure a
secure installation
2.Three installation method
options:
i. SURFACE WALL MOUNT
INSTALLATION (pg. 11)
ii. FULLY RECESSED WALL MOUNT
INSTALLATION (pg. 14)
iii. PARTIALLY WALL MOUNT
INSTALLATION (pg. 15)
3.Hardwired or plug-in method
CAUTION: Ensure installation
does not allow fireplace to be in
direct contact with building vapor
barrier or insulation and meets all
local building code.
!NOTE 1: A 15 Amp, 120 Volt
circuit is required. A dedicated
circuit is preferred but not
essential in all cases. A dedicated
circuit will be required if, after
installation, the circuit breaker
trips or fuse blows on a regular
basis when the heater is
operating. Additional appliances
on the same circuit may exceed
the current rating of the circuit
breaker.
WARNING: Ensure the power
cord is not installed so that it is
pinched or against a sharp edge
and ensure that the power cord
is stored or secured to avoid
tripping or snagging to reduce
the risk of fire, electric shock o
injury topersons.
Construction and electrical
outlet wiring must comply
with local building codes and
other applicable regulations to
reduce the risk of fire, electric
shock and injury to persons.
WARNING: To reduce the risk
of fire, do not store or use gas -
line or other flammable vapors or
liquids in the vicinity of the heater.
1.
Select a location that is not
susceptible to moisture and
is away from drapes, furniture
and high traffic
2.
For ease of electrical hook up
you may wish to locate the
fireplace near an existing outlet
(for plug-in convenience) (refer
to pg.9).
3.
Remove fireplace, front glass
and hardware from box and
remove all packaging materials
before installation.
4.
Store the fireplace in a safe
dry and dust free location until
you are ready to install the
fireplace.

7
Fireplace Installation
MINIMUM CLEARANCE
Measurements are taken from the glass front.
Bottom
0" (can be put on the floor)
Top
11.8" (300mm) to mantel
Sides
0" (can go to the edge of the wall)
Top
11.8" (300mm) to ceiling
Back
0"
Top
25" (635mm) to TV
MINIMUM MANTEL & TV CLEARANCES
WARNING
WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST
BE HEAT RESISTANT TO PREVENT DISCOLOURATION.
11.8”
300mm
0”
0”
0”
Wall
Floor
25” (635mm)

8
Fireplace Installation
Wiring Diagram
Hard wire Installation
The fireplace is packaged with a three prong plug installed for plug-in
convenience. Hard wiring the fireplace is also an option for any
installation.
WARNING: Do not attempt to wire your own newoutlets or circuits.
To reduce the risk of fire, electric shock or injury persons, always usea
licensed electrician.
WARNING: Ensure that the power cut off at the service paneluntil
installation is complete.
BG-36/50B

9
Fireplace Installation
HARD WIRING CONNECTION
If it is necessary to hard wire this appliance, a qualified electrician must remove the cord connection, and
wire the appliance directly to the house hold wiring.
This appliance must be electrically connected and grounded in accordance with local codes, if hard wired.
In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or
the current ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.
A.
Remove the cover plate from the right side B. Remove the wire connectors from the power
bottom of the appliance by removing the three
screws, as shown above.
cord. The power cord may be discarded.
C.
Take the new cover plate, supplied in the hardware bag. Punch out the 7/8" (22.2mm) hole and
install a box connector through, into the junction box. Snap the box connector clamp onto the supply
wires.
D.
Using the wire connectors, connect the ground green wires (G), the common white wires
(N) together, then the hot black wires (L) and then the refer to Figure 3.
E.
Re-install the cover plate using the three screws, as shown in Figure 1.

10
Fig. 4-1
Fig. 4-2
Fireplace Installation
Front glass removal / installation
A. With one hand on the front glass to prevent it from falling, remove the
two screws (1 per side) from the side of the appliance (Fig. 4-1). Set the
screws aside.
B. Carefully lift the front glass up and away from the appliance (Fig. 4-2
and 4-3). Place it face down on a soft, non-abrasive surface.
C. Reverse these steps to install the front glass.
1
2
Fig. 4-3
Autres manuels pour BG-36B
1
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels CSA Cheminée intérieure


















