Figure 1
Connection Diagram
Introduction
The CC-20 Automatic Charge Controller senses
battery voltage and connects/disconnects your
charging source (solar panels, dumb charger)
depending on the battery voltage. The CC-20
enablesyoutoleaveyourchargingsourceconnected
permanently without fear of damaging overcharges
or excess electrolyte loss. You are assured you
have a fully charged battery whenever you need it.
Three front panel LEDs show you what the CC-20
is doing at all times: in "Charge" mode, "Float"
mode, or if your battery is in an overcharged
"High" condition.
The lower and upper trip limits are factory preset
at 13.1 and 14.4 VDC but can easily be adjusted
from 11.5 to 14.5 VDC (low limits) and 13.5 to
16.5 VDC (high limits) thereby covering wet, gell
and Ni-Cd batteries. Accuracy is maintained to +/
- 0.05 VDC over the full operating temperature
range. The CCA-20 handles up to 8 amps at an
efficiency of 99.8% at 8 amps.
Operation/Adjustment of the CC-20
When the CC-20 is properly installed, one of the
LED's should be on (continuously or blinking). If
the battery voltage is above the lower trip point the
"Charge" LED or the "Float" LED will be blinking.
If the battery is already above the upper trip point,
the "High" LED will be ON continuously. When
the battery voltage drops below the upper trip point
the "Float" LED will blink. If the battery voltage
drops below the lower trip point the "Charge" light
will blink.
To change the factory-set upper and lower trip
points, adjust the "HI" and "LO" potentiometer
with a small screwdriver (See Figure 1). Adjust
the appropriate potentiometer while measuring the
corresponding "HI" and "LO" voltages with a high
input impedance Digital Voltmeter (DVM) at the
test points next to the potentiometers. Do not force
the potentiometers past the end stops! The
adjustments are independent of each other and can
be performed in either order.
Installation
Before starting the installation, please read this
entire section for any warnings. The instrument
is NOT water-proof and must be located in an area
that will not get wet.
Remove the case front and align the case back onto
any suitable surface. Using the case back as a drill
guide, mark the location of the two holes with a
soft pencil lead. Remove the case back and drill
two 2mm (3/32 inch) holes where indicated. Mount
the case back using the two stainless countersunk
screws provided.
In the next paragraph you will connect four wires
to the CC-20 screw terminals, one wire per termi-
nal. Do not connect the loose ends of these wires
until later. When connecting wires to the screw
terminals be sure that there are no exposed loose
strands of wire that might later cause a short and do
not overtighten the screw terminals.
Thread a 22 gauge or larger ground wire through
the rubber grommet on the front case and connect
it to the terminal marked "BATT. -" (See Figure
1). Similarly thread a 16 gauge or larger wire for
the +12 VDC battery connection and connect to
the terminal marked "+ BATT." (do not connect to
the battery yet).