CORNING SCRN-530 Manuel

SCRN-530 Hardware Installation Guide | DOC-SCRN-530-HIG | 21 July, 2021 | Page 1Small Cell Radio Node - SCRN-530 Hardware Installation GuideDOC-SCRN-530-HIGIssue 1Related Literature | Search www.Corning.com/opcomm. Click Required Resources.Table 1 Revision HistoryIssueDateSummary of Changes121JUL21First issue for SCRN-530 Small Cell Radio Node.

SCRN-530 Hardware Installation Guide | DOC-SCRN-530-HIG | 21 July, 2021 | Page 2Table of ContentsFCC Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Other Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Section 1.System Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Section 2.Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Section 3.Radio Node Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Section 4.SCRN-530 Views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Section 5.Connectors, SFP+ and Micro-USB Ports, and Status LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85.1Phoenix Power Cable Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85.2SFP+ Transceiver Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85.3Micro-USB Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85.4Status LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Section 6.System Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Section 7.Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Section 8.Mounting the SCRN-530 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118.1Installing the SCRN-530 on a Ceiling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118.2Installing the SCRN-530 on a Wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13Section 9.Cabling Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15Section 10.Completing the Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Section 11.Detaching the SCRN-530 from the Mounting Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Section 12.SCRN-530 LED Boot Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Section 13.SCRN-530 LED Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Section 14.Disabling the LED Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Section 15.Re-Enabling the LED Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Section 16.SFP+ LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Section 17.Corning Documentation Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

SCRN-530 Hardware Installation Guide | DOC-SCRN-530-HIG | 21 July, 2021 | Page 3FCC StatementsSafety PrecautionsCorning strongly recommends reviewing and adhering to the following cautions and notices before installing and operating the SCRN-530. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment.RF Exposure Warning Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum 40 cm between the radiator and your body. This transmitter must not be collocated or operating in conjunction with any other antenna or transmitter unless authorized to do so by the FCC.This device can be expected to comply with part 15 of the FCC Rules provided it is assembled in exact accordance with the instructions provided with this kit. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation.NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.WARNING: This warning symbolizes danger that may cause severe injury or death. Before installing or servicing equipment ensure that you are aware of all hazards involved with electrical circuitry and become familiar with applicable safety standards and national and local electrical codes and any other relevant standards.WARNING: For Professionals & Trained Installers:• The device is designed for wall mount or ceiling mount applications only in an enterprise environment.• Installers are required to maintain RF safety distances of 40 cm during the course of installation process.• Wall installation should be avoided, if a minimum safety distance of 40 cm cannot be maintained. WARNING: All electrical equipment must be properly grounded. Refer to national and local electrical codes and any other relevant standards for electrical grounding information.

SCRN-530 Hardware Installation Guide | DOC-SCRN-530-HIG | 21 July, 2021 | Page 4Other CautionsCAUTION: ESD can damage the SCRN-530 and internal components. Ensure that the SCRN-530 and associated antenna equipment is installed and serviced according to national and local ESD standards.CAUTION: Do not open the SCRN-530 casing. E-RAN wireless system equipment must only be serviced by Corning-accredited personnel. Opening the SCRN-530 casing voids the warranty.

SCRN-530 Hardware Installation Guide | DOC-SCRN-530-HIG | 21 July, 2021 | Page 51.System OverviewThe Corning SCRN-530 small cell radio node is a high-performance integrated 5G new radio (NR) mmWave small cell that is part of the Corning enterprise radio access network (E-RAN). The scalable SCRN-530 radio node and the enterprise radio access network (E-RAN) simplify the complexity of radio management and mobility, and provide operators with a single touchpoint to aggregate and manage a large network of 5G small cells. This guide provides the system specifications of the SCRN-530. It includes detailed hardware installation instructions, the boot sequence, and expected LED behavior both during the boot-up and under normal operating conditions. NOTE:The SCRN-530 small cell radio node is referred to as “radio node” in the rest of this document.NOTE:The 5G New Radio (NR) is a new radio access technology developed by 3GPP for fifth generation (5G) mobile networks.The primary audience for this guide includes network planners, system administrators and installation personnel. It assumes you have knowledge about networking principles, networking configuration, site preparation, powering, and experience in hardware installation and maintenance.2.Product OverviewThe SCRN-530 is a 5G mmWave Time Division Duplexing (TDD) radio node that supports 2 x 2 MIMO small cell operation on NR band n260, enabling high user capacity and high data rates for the coverage footprint. The radio node connects to a Corning centralized unit (CU). It uses certificate-based authentication with the Corning CU. Radio Nodes are managed by the Corning centralized units installed in the enterprise or in a centralized location such as a data center. The SCRN-530 includes built-in self-organizing networks (SON) features for ease of deployment. Its fronthaul network can be deployed using approved 10 Gb fiber optic cables. The SCRN-530 receives 48 VDC power from a Corning PSU6 DC Power Supply Unit or equivalent. There is no management or console port on the SCRN-530, and the radio node is physically locked to prevent theft. The SCRN-530 is passively convection-cooled, and its antennas are built-in. Each SCRN-530 comes with a ceiling-mount bracket attached for installing directly to a flat surface, as well as a second multi-angle (0, 15, 30, and 45 degree) wall-mount bracket loose in the box. The SCRN-530 uses on-chip Trusted Platform Module (TPM) functions to implement secure boot, and to establish certificate-based IPsec tunnels to the centralized unit. It

SCRN-530 Hardware Installation Guide | DOC-SCRN-530-HIG | 21 July, 2021| Page 6includes a PTP client to achieve frequency and phase synchronization with other mmWave radio nodes and base stations. The E-RAN element management system includes configuration, fault and performance monitoring, and security functions. Figure1 shows the architecture of the 4G and 5G E-RAN network.Figure 14G and 5G E-RAN Architecture3.Radio Node ModelTable1 includes the SCRN-530 model configuration.Table 1 Radio Node ConfigurationRadio Node ModelDescriptionAntenna TypeSCRN-530-3939 GHz band n260 mmWave RN with 8 x 8 dual-polarization antenna arrayInternal
Email Web
DMZ
Enterprise
Mobile
Operator
Core
SCRN-530
Radio
Nodes
5G RN
Fronthaul
Core
Switch
Firewall
Security
Gateway
5G
EN-DC
UEs
PSU6
5G Centralized
Unit (CU)
NR
(5G)
DC
Power
10G
Connections
4G RN
Fronthaul
PoE+
Switch
4G Services
Node (SCSN)
4G and 5G EN-DC RAN
LTE
(4G)
CU IPsec
Backhaul
S1-U
3GPP
GTP Tunnel
4G
Radio
Nodes
1G
Connections
SCSN IPsec
Backhaul
3GPP
Tunnel
X2
4G
UEs

SCRN-530 Hardware Installation Guide | DOC-SCRN-530-HIG | 21 July, 2021 | Page 74.SCRN-530 ViewsFigure2 and Figure3 display views of the SCRN-530.Figure 2SCRN-530 CoverFigure 3SCRN-530 With Ceiling-Mount Bracket

SCRN-530 Hardware Installation Guide | DOC-SCRN-530-HIG | 21 July, 2021 | Page 85.Connectors, SFP+ and Micro-USB Ports, andStatus LEDThe SCRN-530 has connectors and a small form-factor pluggable SFP+ port, as shown in Figure4.Figure 4SCRN-530 Connectors and Status LED5.1Phoenix Power Cable PortThe SCRN-530 has a 48 VDC power connector for delivering power from a Corning PSU6 DC Power Supply Unit or equivalent to the radio node. Plug the Phoenix power connector from the power source cable into the power connector.5.2SFP+ Transceiver PortThe SFP+ Transceiver Port accommodates a compact enhanced small form-factor pluggable (SFP+) network interface module. The hot-pluggable SFP+ supplied with this SCRN-530, must be installed in the Transceiver Port. The LC connector, terminated end, of the fiber pair of an ActiFi cable (or other approved fiber cable) is then connected to the SFP+ LC Ports to provide fronthaul transport network access to the radio node. Refer to Section 16. SFP+ LED Indications for more information.5.3Micro-USB PortThe Micro-USB port is completely disabled and is not available for general use.5.4Status LEDThe STA (status) RGB tri-color LED indicates the state of the SCRN-530, with boot, normal, disabled, fault, and SCRN-530 indications. When the radio node initially boots, the LED cycles through a number of colors and flashing behaviors until the radio node is fully operational. Section 12. SCRN-530 LED Boot Sequence describes the STA LED indications.

SCRN-530 Hardware Installation Guide | DOC-SCRN-530-HIG | 21 July, 2021| Page 96.System SpecificationsThe SCRN-530 has the chassis measurements, power requirements, and environmental requirements, and complies with the standards listed in Table2. Refer to the feature guide for your centralized unit software release for release-specific features and specifications.Table 2 SCRN-530 SpecificationsOperating Band2 x 2 MIMO operation on 39-GHz NR band n260 (37.0 – 40.0 GHz)Channel SizeComponent Carrier (CC) bandwidth: 100 MHzAntenna Type8 x 8 dual-polarization internal antenna arrayAntenna Power43 dBm EIRP @ 64QAMBeamforming scan range: +/- 60 degreesRF ManagementBeam Management with auto-assignment of physical cell identities (PCIs)QoS FeaturesNon-GBR bearer support per UEDimensions279.4 x 279.4 x 80.3 mm (11.0 x 11.0 x 3.16 in)Weight4.5 kg (9.9 lbs)Input Power1 x 48 VDC Phoenix, deliverable using Corning® ActiFi® 2-fiber/2-copper conductor composite cablePower Consumption70 WIngress ProtectionIngress protection rating: IP30Performance4CC; up to 64 active usersPeak Tx Rate1.8 Gbps DL, 60 Mbps UL (DL:UL slot ratio of 4:1) @ 64QAM with 4CC DL, 1CC ULLicensed Tx PowerEquivalent isotropically radiated power (EIRP): 43 dBmFronthaul NetworkDeployable over Corning® ActiFi® 2-fiber/2-copper conductor composite cableEthernet InterfaceSFP+ supports 10 GbE (Gigabit Ethernet)LEDs1 tricolor (RGB) LED to indicate power and status, 2 SFP LEDs to indicate Link/Activity statusSynchronizationIEEE 1588v2-based (PTP) synchronization with an external PTP grandmaster clockMountingWall or Ceiling, brackets includedBrackets support four wall-mount tilting options: 0°, 15°, 30°, and 45° tiltCooling MethodPassive convection cooling

SCRN-530 Hardware Installation Guide | DOC-SCRN-530-HIG | 21 July, 2021 | Page 107.ComplianceThe SCRN-530 complies with the standards listed in Table3.SecuritySecure boot and secure key storage using Trusted Platform Module (TPM) functionsIPsec tunneling to NR CU (Centralized Unit)X.509 certificate-based authenticationEnvironmental RequirementsOperating temperature range: 0 to 45°C (32° to 113°F)Non-operating temperature range: -40° to +70°C (-40° to 158°F)Relative humidity: Operating and storage: 5% to 90% RH non-condensingMTBF1,363,791 hours at +40°C (104°F)Table 3 Radio Node Compliance SafetySafety: UL-62368-1 2nd EditionFCC Compliant: Part 15 (Class A), Part 30 FCC 47 CFR 1.1307(b)MPE: FCC 47 CFR 1.1310Table 2 SCRN-530 Specifications (continued)
Table des matières