CORAL UV UVLEDW106 Manuel utilisateur

User Manual / Manuel de l’usager / Manual de Usuario
Model: UVLEDW106

SPECIFICATIONS
Model: UVLEDW106
Net Weight: 8 lbs (3.6 kg)
Electrical Specs: 120V, 60Hz, 160W max
Dimensions (H x W x D): 9 x 12.5 x 11 in
Inside Dimension (H x W x D): 7.1 x 11.2 x 8.6 in
UV-C wavelength: 260-280nm
UV-C wattage: 12mw max per LED light
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
WARNING: Any changes or modications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the product.
Registrant Name and Address:
Too Inc, dba Coral UV
1306 FM 1092 Rd Ste. 406, Missouri City, TX 77459
1833-267-2588
service@coraluv.com
CERTIFICATIONS
This device complies with The Code of Federal
Regulations, CFR Title 21, Part 1040, Chapter 1,
Subchapter J, Radiological Health.

Contact Us
1-833-CoralUV (267-2588)
service@coraluv.com
www.coraluv.com
@coraluvbaby
Thank you for choosing Coral UV!
Your product comes with a 2 year warranty. Activate at:
coraluv.com/registerwarranty Or scan the QR code below.
Merci d’avoir choisi Coral UV!
Votre produit est couvert par une garantie de 2 ans. Activez-le dans:
coraluv.com/registerwarranty. Ou scannez le code QR ci-dessous.
¡Gracias por su preferencia!
Su producto viene con una garantía de 2 años. Actívala en:
coraluv.com/registerwarranty. O escanee el código QR a continuación.

CONTENTS / CONTENU / CONTENIDO
CONTROL PANEL / PANNEAU DE CONTRÔLE / PANEL DE CONTROL
(1) UV Sanitizer and Dryer
(1) Stérilisateur et Sécheur UV
(1) Sterilizador y Secador UV
Basket
Panier
Canasta
Chamber
Chambre
Cámara
Vent / Ventilation / Salida de Aire
Filter / Filtre / Filtro
Cerradura
Filter Lock
Fermeture du Filtre
Bouton d’
Ouverture
Botón de abrir
Open
Button
Bombilla LED
Ampoule LED
LED Bulb
(3) HEPA Filter
(3) Filtre HEPA
(3) Filtro HEPA
ON/OFF SANITIZE
+ DRY SANITIZE
ONLY 24-HOUR
STORAGE
(1) User Manual
(1) Manuel de L’usager
(1) Manual de Usuario

INDEX
Important Safety Instructions 5
Getting Started 6
Operation Modes 6
Starting a Cycle 7
Placing Items 7
Maintenance 8
Warranty 9–10
CONTENU
Consignes de Sécurité Importantes 11
Guide de Démarrage 12
Modes de Fonctionnement 12
Démarrage un Cycle 13
Insertion d’Objets 13
Maintenance 14
Garantie 15–16
ÍNDICE
Importantes Instrucciones de Seguridad 17
Antes de Empezar 18
Funciones 18
Iniciar un Ciclo 19
Insertar Objetos 19
Mantenimiento 20
Garantía 21–22

READ ALL INSTRUCTIONS BEFORE USE. This product is for adult use only.
Children and persons with reduced physical, sensory or mental capabilities
should not operate the product. When using an electrical appliance, basic
precautions should always be followed. FOR HOUSEHOLD USE ONLY. DO
NOT USE OUTDOORS.
• WARNING: The product contains a UV
emitter. Do not stare at light source.
•WARNING: This product is built with
safety mechanism to prevent exposure
to excessive UV radiation. Do not tamper
with the safety operation switch. Lid
should remain closed during operation.
•WARNING: To reduce the risk of re,
electric shock, or injury:
•Do not leave equipment when plugged
in. Unplug from outlet when not in use or
before servicing.
•Do not use as a toy. Close attention is
necessary when used near children.
•Do not handle the plug or the product
with wet hands.
•Do not pull or carry by cord, use cord as a
handle, close a door on cord, or pull cord
around sharp edges or corners. Do not run
equipment over cord. Keep the product
and cord away from heated surfaces and
heat sources.
• Do not use with damaged cord or plug. If
equipment is not working as it should, has
been dropped, damaged, left outdoors, or
dropped into water, return it to a service
center.
•Turn off all controls before unplugging.
•Do not unplug by pulling on cord. To
unplug, grasp the plug, not the cord.
•Use only as described in this manual.
Use only manufacturer’s recommended
attachments/accessories.
•CAUTION: To provide continued
protection against risk of electric shock,
connect to properly grounded outlets
only. Do not modify the plug.
•Always place the product on a level and
rm surface. Always power off and unplug
the product before moving it.
•Never insert any objects into the vent,
holes, or any opening.
• A short power cord is provided to reduce
the risks of becoming entangled in or
tripping over a longer cord.
• If power cord is damaged, contact us to
replace it. Do not replace by yourself.
• Extension cords may be used if care
is exercised in their use. The marked
electrical rating of the extension cord
should be equivalent to the product’s
electrical rating. The extension cord
should be a grounding-type 3 pin cord.
The extension cord should not drape over
the counter top or tabletop where it can
be tripped over, snagged, or pulled on
unintentionally, especially by children.
•Keep a minimum 4-inch space between
the back of the product and the wall.
•Do not place or store the product where it
can fall or be pulled into a tub or sink.
•Do not operate the product in an area
where an aerosol product is being used or
oxygen is being administered.
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
5

Before you start the rst cycle, please follow the steps below:
1. Use a damp cloth and gently wipe the chamber.
2. Then, use a dry cloth to ensure there are no water droplets remaining.
3. Run an empty sanitize + dry cycle for 60 minutes.
GETTING STARTED
6
OPERATION MODES
BUTTON FUNCTION TIME
sanitize + dry
Sanitizes within the rst 10
minutes, followed by a drying
cycle for a specic time.
40 minutes (10 UV, 30 Dry)
50 minutes (10 UV, 40 Dry)
60 minutes (10 UV, 50 Dry)
sanitize only This setting runs with UV
lights only. It is recommended
for items that cannot be
washed nor dried.
10 minutes
20 minutes
30 minutes
24-hour
storage
This setting runs a 50 minute
sanitize + dry cycle, followed
by a 2 min sanitize only cycle
every 2 hours for the next 24
hours.
50 minutes: sanitize+dry
+
2 minutes: sanitize only

1. Ensure the lid is securely closed.
2. Press the power button to start. Then press the desired function
button. The button and the number of minutes will blink in the display.
3. Continue pressing the function button until you reach the desired
number of minutes.
4. Stop pressing the button and wait for the timer to stop blinking.
5. The cycle will start and run for the specied time..
STARTING A CYCLE
WARNING: Do NOT overload or stack items inside the chamber. The
height of all items placed in the chamber shall not exceed 7.1in.
PLACING ITEMS
7
•Remove all lids
and separate all
parts of a product.
•All openings must
be facing up or
sideways.
•Ensure there is
adequate space
between objects.
•Flip large items
and repeat cycle
to sanitize the
other side.
•Remove excess
water from all
objects.
Only sanitize items that can withstand a moderate level of UV light exposure.
When placing items in the chamber or basket:

MAINTENANCE
8
CHAMBER MAINTENANCE
1. Unplug the machine.
2. Use a damp cloth or paper towel to wipe the walls inside the chamber
to remove any residues.
3. Wipe with a dry cloth to ensure no marks or dust are left behind in the
chamber, as they can negatively affect sanitation.
ATTENTION: Do not wipe the LED cover with water. Wipe with a
dry cloth only. Do not use chemicals to clean the product.
ATTENTION: Do not clean or reuse the HEPA lters. Only insert
approved HEPA lters from Coral UV. Dispose used lters
according to your local regulations.
REPLACEMENTS
•Replace the HEPA Filter every 5-6 months if used daily.
1. Unplug the machine and locate the HEPA lter on the back of the
product.
2. Insert a coin or at object into the guiding arrow and turn it to the
unlock position.
3. Remove the old lter and insert the new HEPA lter.
4. Turn the guiding arrow back to the locked position to secure the lter.
•Do NOT attempt to replace UV-C LED bulbs. Do not disassemble or
repair the product by yourself. Failure to follow this requirement will void any
warranty. Contact service@coraluv.com for all servicing requests.
• Do not store this product outdoors, in an extreme hot or cold environment or
in an environment not suitable for electrical appliance storage.

The Coral UV product warranty is offered by Coral UV. Throughout this
warranty, the terms “we”, “us”, and “our” refer to Coral UV.
We do not authorize anyone, including, but not limited to, retailers, the
subsequent consumer purchaser of the product from a retailer, or remote
purchasers, to obligate us in any way beyond the terms set forth herein. We
warrant our products to be free from substantial defects in workmanship and
materials under normal household use in accordance with the instructions
for warranty period following the date of purchase. We will, at our discretion,
replace or repair any item requiring service. This warranty shall not apply to
damage arising from neglect, accidental damage, or improper use of the
product. This is a limited warranty which extends only to consumers and does
not extend to retailers. Proof of purchase is required. Self-disassembling the
product will void the warranty.
WARRANTY PERIOD
We provide 2 year warranty for Coral UV LED Sanitizer & Dryer. The warranty
period starts at the date of retail and/or online purchase of the product by
the original purchaser from an authorized retailer.
REPLACEMENT/CREDIT
If the product fails to meet the limited warranty conditions during the
warranty period, we will, at our option, replace the product free of charge or
provide you with a replacement of comparable value. Proof of purchase is
required to request service or replacement.
WARRANTY
9
Table des matières
Langues :