Control Applications Elnet GR Manuel utilisateur

Elnet GR
Electrical Measurements & Power Quality

2
Table of Contents
CHAPTER 1 ─INTRODUCTION.......................................5
1.1 About the ElNet Multimeter.................................5
1.2 How to use this manual ...........................................6
1.3 Safety Information...................................................8
1.4 Warranty..................................................................9
1.5 Your comments are welcome.................................11
1.6 Disclaimer...............................................................12
CHAPTER 2 — INSTALLATION......................................13
2.1 Contents of packaging...........................................14
2.2 Mechanical mounting............................................15
2.3 Wiring Schematics.................................................17
2.4 Rear Panel Connections ........................................18
2.5 Manufacturing Data..............................................23
CHAPTER 3 — USING THE ElNet Multimeter .............24
3.1 Front Panel.............................................................24
3.2 Control Buttons......................................................25
3.3 Lock Utility.............................................................26
CHAPTER 4 — NECESSARY ElNet SETTINGS ...........29
4.1 Settings for Current Transformer........................30
4.2 Electrical Connection Check.................................35

3
4.3 TOU Setting............................................................37
4.4 Change language....................................................38
4.5 Time Settings..........................................................38
4.6 Date Settings...........................................................40
4.7 Zero Accumulating Values ....................................41
CHAPTER 5 — FRONT PANEL DISPLAYS....................42
5.1 Current for 3 Phases..............................................42
5.2 Frequency for 3 Phases..........................................43
5.3 Current in Neutral Line........................................44
5.4 Voltage for 3 Phases...............................................46
5.5 Active Power for all 3 Phases (P)..........................47
5.6 Reactive Power for all 3 Phases (Q) .....................49
5.7 Apparent Power for all 3 Phases (S).....................50
5.8 Power Factor for each Phase.................................51
5.9 Overall Power Factor ............................................52
5.10 Active Energy......................................................53
5.11 Reactive Energy..................................................54
5.12 Apparent Energy ................................................55
5.13 Power Quality .....................................................56
5.13 .1 Wave Form Graphs......................................56
5.13 .2 Harmonics Bar Graphs................................61
5.13 .3 Voltage Total Harmonic Distortion (THD).64
5.13 .4 Current Total Harmonic Distortion (THD)65

4
5.13 .5 Current THD,TDD,KF.................................67
CHAPTER 6 — ALARM REPORT....................................68
6.1.1. Alarm setting.................................................69
6.1.2. Display Alarms Report.................................71
CHAPTER 7 — DEMAND REPORTS ..............................72
CHAPTER 8 — DATA LOGGING.....................................73
CHAPTER 9 — COMMUNICATION................................76
9.1 Communication Connections................................76
9.2 Communication Settings .......................................76
9.3 Address................................................................77
9.4 Baud Rate............................................................77
9.5 Parity...................................................................78
9.6 Communication Set Up .........................................78
9.7 Communication with UniArt Software................82
CHAPTER 10 — Specifications .........................................84
Appendix A — Installation & Configuration Check List...85

5
CHAPTER 1 ─INTRODUCTION
1.1 About the ElNet Multimeter
Large consumers of electricity e.g. factories, hotels, hospitals,
municipalities, need to know the history of their consumption and
the quality of the power supply. Details such as Voltage, Current,
Power Factor, Hertz, Neutral Current, Energy Demands and all
electricity related events are recorded in the ElNet Energy &
Power Multimeter.
An additional feature of the Multimeter is the ability to measure
Harmonics. Part of the Electricity Supply Authority’s bill reflects
poor or good Harmonics in the consumer’s system, therefore it is
in his interest to monitor Harmonics and try to improve it.
These are all recorded on a continual basis and can be recalled
and shown on the front panel display of the instrument with a few
simple key-strokes any time the user wishes.
The ElNet Energy & Power Multimeter is a compact, multi
functional, three-phase Multimeter simple to install and is
especially designed to integrate into Building Management
Systems. It requires no special mounting and is ideally suited for
mounting on the front face of any standard electrical panel.
The Configuration and Setup is menu driven, with password
protection.
Communication with external devices is simple and is based on
standard known technology.
The ElNet Energy & Power Multimeter boasts a new
innovative built in “Flash Memory”, which pioneers a new
frontier into electrical measurement. It has a 1 MB of FLASH

6
MEMORY with a capacity of recording up to 2 years of power
malfunctions and interruptions.
Readings, graphs, tables & history are shown on the graphic
display of the ElNet Energy & Power Multimeter
.
This
display is a state of the art screen with a resolution of 160X128.
Each ElNet Energy & Power Multimeter is carefully and
meticulously manufactured using quality components and the
latest production methods. Before leaving the factory each
ElNet Energy & Power Multimeter is calibrated and sent to
the customer accompanied by the test certificate and Certificate of
Compliance (C.O.C).
1.2 How to use this manual
We at CONTROL APPLICATIONS Ltd, envisage this manual to
be used by three types of people, i.e. the Installation Technician,
the Senior Electrical Engineer and the end User. For this reason
this manual is divided into chapters for ease of reference by each
of these different people. There could be a situation where two of
the abovementioned tasks can be combined, or in a rare instance
one person could handle all three tasks.
CHAPTER 1, Introduction, describes the ElNet Energy &
Power Multimeter
,
its potential users, the readings it can
provide and some of its features in brief.
CHAPTER 2, Installation, provides detailed instructions for
unpacking, mechanical mounting, and electrical wiring up
instructions for the Installation Technician.

7
CHAPTER 3, Using the ElNet Energy & Power
Multimeter, describes in detail front Panel, the functions of the
control buttons, and the Lock Utility.
CHAPTER 4, Parameter Configuration & Settings explains in
detail the minimum parameters settings needed by the Senior
Electrical Engineer to set up and configure the ElNet Energy
& Power Multimeter.
CHAPTER 5, Front Panel Displays, is an easy to follow step-by-
step guide to obtain readings, graphs, tables and histories for the
User.
CHAPTER 6, Alarm reports gives details about how to program
the Alarms in the ElNet Energy & Power Multimeter.
CHAPTER 7, Demand reports is an easy to follow step-by-step
guide to obtain the Demand reports up to 2 years.
CHAPTER 8, Data Logging is an easy to follow step-by-step
guide to obtain all the stored peaks of current, voltage, energy,
power factor etc. up to 2 years of data logging.
CHAPTER 9, Communications gives details about the
Communication capabilities of the ElNet Energy & Power
Multimeter, and how to Set Up.
CHAPTER 10, Specifications, is a detailed list of specifications of
the ElNet Energy & Power Multimeter.
APPENDIX A, Installation & Configuration Check List, provides
a Check List to insure no important steps will be missed during
the initial set up.

8
1.3 Safety Information
The purpose of this manual is to help you. Please read the
instructions carefully before performing any installation and note
any precautions.
•Ensure that all incoming AC power and other
power sources are turned off before
performing any work on the ElNet
Energy & Power Multimeter
.
Failure to
do so may result in serious or even fatal
injury and/or equipment damage.
•If the ElNet Energy & Power
Multimeter is damaged in any way do NOT
connect it to any power source.
•To prevent a potential fire or shock hazard,
never expose the ElNet Energy & Power
Multimeter to rain or moisture.
•Keep the surrounding area free of dirt and
clutter especially metal objects. Good
housekeeping pays.
•Inspect the cables periodically for cracks,
kinks or any other signs of wear
•Keep children away.
•Do not pull the cords.
WARNING

9
•Users should stay alert and not approach the
rear of the ElNet Energy & Power
Multimeter while tired or under the
influence of alcohol, medicines or any other
chemical substance that would tend to make a
person drowsy.
•Do not wear loose clothing or dangling
jewelry.
•Above all use common sense at all times.
1.4 Warranty
CONTROL APPLICATIONS Ltd provides a 12- Month warranty
against faulty workmanship or components from date of dispatch
provided that the product was properly installed and used.
CONTROL APPLICATIONS Ltd does not accept liability for any
damage that may be caused by natural disasters (such as floods,
fire, earthquake, lightening etc.).
CONTROL APPLICATIONS Ltd does not accept liability for any
damage that may be caused by malfunction of the ElNet
Energy & Power Multimeter.
CONTROL APPLICATIONS Ltd will advise the customer on the
proper installation and use of the ElNet Energy & Power
Multimeter
,
but will not accept any responsibility that the
instrument is suitable for the application for which it was
originally purchased.
This warranty may become void if the Installation; Parameter
Configuration & Setting Instructions are not carried out according
to the instructions set out by CONTROL APPLICATIONS Ltd.

10
The ElNet Energy & Power Multimeter has no user
serviceable parts and should be opened and serviced by a duly
qualified authorized representative only. The sensitive electronics
could become damaged if exposed to a static environment. This
action would void the warranty.
This warranty is limited to the repair and/or replacement at
CONTROL APPLICATION Ltd sole discretion of the defective
product during the warranty period. Repaired or replaced products
are warranted for ninety (90) days from the date of repair or
replacement, or for the remainder of the original product’s
warranty period, whichever is longer.
CONTROL APPLICATIONS Ltd is always at your service to
advise the customer on any problem that may be encountered
regarding any installation, operation, parameter & configuration
settings or maintenance.