Contacta Limited SecuriCom Guide de l'utilisateur

SecuriCom™
SPEECH TRANSFER SYSTEM
SYSTEM MANUAL
Contacta Limited
Head Office: Imex House, Sales Office: 50 Churchill Square,
VIP Trading Est., Anchor & Hope Lane, King’s Hill, West Malling,
Charlton, London SE7 7TE. UK Kent ME19 4YU. UK
Tel: 020 8858 2123 • Fax: 020 8858 4866 Tel: 01732 223900 • Fax: 01732 223909

Contents Page
4Product Overview
5System Components
6System Options
7Configuration: Bridge Bar System
8Configuration: Surface Mounting System
9Configuration: Flush Mounting System
10 Installation
13 Fitting Instructions: Bridge Bar System
14 Fitting Instructions: Surface Mounting System
15 Fitting Instructions: Flush Mounting System
16 Fitting Instructions: Staff Unit
17 Operation: Instructions
18 Operation: Optional Hearing Aid Induction Loop
19 Other Contacta Products
SECURICOM SPEECH TRANSFER SYSTEM CONTENTS
3

Product Overview TheSecuriComSpeechTransferSystemisatwo-wayintercomspecificallydesignedtoaid
communications where normal speech is impaired by the use of glass security screens or
other similar barriers.
Every system is controlled and powered individually and operates on a stand-alone basis.
Each system comprises a twin-channel audio amplifier, power supply unit, a microphone
and speaker for the staff and a microphone and speaker for the customer. The microphone
and speaker modules are supplied in various formats to enable the system to be installed
in differing locations.
The system operates on an “Open Duplex” basis, i.e. microphones and speakers are live
simultaneously, similar to a telephone, with no manual or automatic switching of the voice.
This means that clipping of speech is not encountered whilst still allowing users to
operate the system “Hands-Free”. Sophisticated electronic circuitry in the amplifier and
purpose designed speaker and microphone modules ensure that the risk of acoustic
coupling or “Feedback” is kept to a minimum.
Securicom also offers an induction loop facility which is built into the system for users of
hearing aids.
SecuriCom is offered either in a system kit format, or as individual modules, thus allowing
maximum flexibility to “tailor” systems to individual requirements.
SECURICOM SPEECH TRANSFER SYSTEM PRODUCT OVERVIEW
4

Part No. Amplifier Power Supply Staff Unit Customer Unit
STS-K001 STS-A20 STS-P41 or STS-F70 STS-B80
STS-P42 Staff Unit Audio Bridge
1a Bridge Bar System with Loop Facility
STS-K001-L STS-A30 STS-P43 STS-F70 STS-B80
Staff Unit Audio Bridge
Induction Loop
IL-E97 Induction Loop Sign
Part No. Amplifier Power Supply Staff Unit Customer Unit
STS-K002 STS-A20 STS-P41 or STS-F70 STS-M54 Microphone
STS-P42 Staff Unit and STS-S60 Speaker
2a Surface Mounting System with Loop Facility
STS-K002-L STS-A30 STS-P43 STS-F70 STS-M54 Microphone
Staff Unit and STS-S60 Speaker
Induction Loop
IL-E97 Induction Loop Sign
SECURICOM SPEECH TRANSFER SYSTEM SYSTEM COMPONENTS
5
1 Bridge Bar System
2 Surface Mounting System
Part No. Amplifier Power Supply Staff Unit Customer Unit
STS-K003 STS-A20 STS-P41 or STS-F70 STS-M56 Microphone
STS-P42 Staff Unit and STS-S61 Speaker
3a Flush Mounting System with Loop Facility
STS-K003-L STS-A30 STS-P43 STS-F70 STS-M56 Microphone
Staff Unit and STS-S61 Speaker
Induction Loop
IL-E97 Induction Loop Sign
3 Flush Mounting System
The STS-F70 Staff Unit comprises loudspeaker and close talking gooseneck microphone
in one discreet unit. An On/Off button mutes the microphone if required for privacy reasons.
4 Staff Unit (common to all systems)

SECURICOM SPEECH TRANSFER SYSTEM SYSTEM OPTIONS
6
Customer Options
Customer’s side 1
Surface mounting components
STS-M54 Microphone
and STS-S60 Loud speaker
Customer’s side 2
Flush mounting components
STS-M56 Microphone
and STS-S61 Loud speaker
Customer’s side 3
Surface mounting components
STS-B80 Audio Bridge
Close talking Microphone
and twin Loud speakers
Staff Option
Staff side 1
STS-F70 Staff Unit
STS-M54 Microphone STS-S60 Speaker
Cash Tray
contacta
Hearing loop is installed
here. Switch your hearing
aid to the T-position.
Optional IL-E93/94/95 Induction Loop
STS-M56 Microphone STS-S61 Speaker
Cash Tray
contacta
Hearing loop is installed here.
Switch your hearing aid to the
T-position.
Optional IL-E93/94/95 Induction Loop
Cash Tray
contacta
Hearing loop is installed here.
Switch your hearing aid to the
T-position.
Speaker
Speaker
STS-B80 Audio Bridge
with goose neck close
speaking microphone
Optional IL-E93/94/95 Induction Loop
Cash Tray
contacta
Hearing loop is installed here.
Switch your hearing aid to the
T-position.
STS-F70 Staff Unit comprising close speaking
microphone, loudspeaker and mute switch
Customer side
Staff side

SECURICOM SPEECH TRANSFER SYSTEM CONFIGURATION
Security Screen
STS-P41/42
Power
Supply
Unit
STS-B80 Customer Audio Bridge
Customer
Staff
STS-A20 Amplifier
STS-F70 Staff Unit
Cabling
A: From Amplifier to
Bridge - Twin
‘Figure of eight’
(2 No.) and one
single core
shielded
B: From Amplifier to
Staff Unit - Combined
speaker and Mic.
cables
220/240 VAC
50Hz
CUSTOM STAF
POWE
contacta
STS-A 20/30
1: Bridge Bar System
Customer: Customer Audio Bridge
Staff: Staff Unit
Security Screen
STS-P43 Power
Supply Unit
STS-B80 Customer Audio Bridge
Customer
Staff
STS-A30 Amplifier
STS-F70 Staff Unit
220/240 VAC
50Hz
Cabling
A: From Amplifier to
Bridge - Twin
‘Figure of eight’
(2 No.) and one
single core
shielded
B: From Amplifier to
Staff Unit - Combined
speaker and Mic.
cables
C: From Amplifier to
Induction Loop -
Twin wire cable
IL-E93/94/95
Induction
Loop
Aerial
CUSTOM STAF
POWE
contacta
STS-A 20/30
1a: Bridge Bar System with
Induction Loop Aerial
Customer: Customer Audio Bridge
Induction Loop Aerial
Staff: Staff Unit
7

SECURICOM SPEECH TRANSFER SYSTEM CONFIGURATION
Security Screen
STS-P41/42
Power
Supply
Unit
STS-M54 Microphone
Customer
Staff
STS-A20 Amplifier
STS-F70 Staff Unit
Cabling
A: From Amplifier to
Speaker - Twin
‘Figure of eight’
B: From Amplifier to
Microphone -
Single core shielded
C: From Amplifier to
Staff Unit - Combined
speaker and Mic.
cables
220/240 VAC
50Hz
STS-S60 Speaker
CUSTOM STAF
POWE
contacta
STS-A 20/30
2: Surface Mounting System
Customer: Microphone and Speaker
Staff: Staff Unit
Security Screen
STS-P43 Power
Supply Unit
STS-M54 Microphone
Customer
Staff
STS-A30 Amplifier
STS-F70 Staff Unit
220/240 VAC
50Hz
Cabling
A: From Amplifier to
Speaker - Twin
‘Figure of eight’
B: From Amplifier to
Microphone - Single
core shielded
C: From Amplifier to
Staff Unit - Combined
speaker and Mic.
cables
D: From Amplifier to
Induction Loop -
Twin wire cable
IL-E93/94/95
Induction
Loop
Aerial
STS-S60 Speaker
CUSTOM STAF
POWE
contacta
STS-A 20/30
2a: Surface Mounting System with
Induction Loop Aerial
Customer: Microphone and Speaker
Induction Loop Aerial
Staff: Staff Unit
8

SECURICOM SPEECH TRANSFER SYSTEM CONFIGURATION
Security Screen
STS-P41/42
Power
Supply
Unit
STS-M56 Microphone
Customer
Staff
STS-A20 Amplifier
STS-F70 Staff Unit
Cabling
A: From Amplifier to
Speaker - Twin
‘Figure of eight’
B: From Amplifier to
Microphone - Single
core shielded
C: From Amplifier to
Staff Unit - Combined
speaker and Mic.
cables
220/240 VAC
50Hz
STS-S61 Speaker
CUSTOM STAF
POWE
contacta
STS-A 20/30
3: Flush Mounting System
Customer: Microphone and Speaker
Staff: Staff Unit
Security Screen
STS-P43 Power
Supply Unit
Customer
Staff
STS-A30 Amplifier
STS-F70 Staff Unit
220/240 VAC
50Hz
Cabling
A: From Amplifier to
Speaker - Twin
‘Figure of eight’
B: From Amplifier to
Microphone - Single
core shielded
C: From Amplifier to
Staff Unit - Combined
speaker and Mic.
cables
D: From Amplifier to
Induction Loop -
Twin wire cable
IL-E93/94/95
Induction
Loop
Aerial
STS-M56 Microphone STS-S61 Speaker
CUSTOM STAF
POWE
contacta
STS-A 20/30
3a: Flush Mounting System
with Induction Loop Aerial
Customer: Microphone and Speaker
Induction Loop Aerial
Staff: Staff Unit
9

System Components
Siting and Installing the Amplifier
Siting and Installing
Microphones and Speakers
1. STS A20 audio amplifier (or A30 version for loop facility)
2. STS-P41/P42 12V DC power supply (or P43 PSU for loop facility)
3. STS-F70 Staff Unit comprising close speaking microphone and loud speaker
4. A microphone for the Customer
5. A loudspeaker for the Customer
6. Induction Loop Aerial (optional)
N.B. Microphones and Loudspeakers are available in flush or surface mounting formats.
The STS-F70 Staff Unit for the staff side is supplied as standard. An alternative option comprising
separate microphones and loudspeakers is also available.
A Customer Audio Bridge with twin surface mounted loudspeakers and a centrally fitted close
speaking microphone is available for the Customer’s side.
Each SecuriCom system requires one Audio Amplifier (STS-A20 or STS-A30) with its associated Power
Supply (STS-P41/42 or STS-P43). The Amplifier connects on a plug and socket basis to other system
components via individual cables.
TheAmplifier shouldbe mountedon aflat surfacewithin closeproximity tothe othersystem com-
ponents and conveniently to hand for the operator. For example, on the staff side under the desk-top
or counter-top would be suitable. Ensure there is also access to the Microphone and Induction Loop
gain controls located on the side of the amplifier and also to the rear connection sockets before fix-
ing. Twin flanges each with two screw holes are formed at the top of the amplifier housing.These are
used to fix the amplifier under the counter top with small self tapping screws.. The Amplifier housing
need not be opened as all connections are external.
Customer Microphones and Loud Speakers may be flush or surface mounted depending on individual
requirements.Seefollowing pagesforfitting instructions.Surfacemountedcomponents arebestsited
atthejunction betweenthe counter-topandthe glasspartition.Forbestperformance, theMicrophone
should be mounted at least 30 centimetres away from the Loudspeaker. Each component comes with
a 3 metre lead and two-way plug. It is advisable to remove the plug before fixing as this enables a
neater installation to be achieved using smaller diameter holes through which to feed the cables.
However, the cables and plugs must be re-connected correctly or the system will not operate. If in
doubt, identify and mark the wires before disconnecting the plug(s).
SECURICOM SPEECH TRANSFER SYSTEM INSTALLATION
Security Screen
Power
Supply
Unit
STS Amplifier mounted
below counter-top
220/240
VAC
50Hz
Cash Tray
Minimum distance between loudspeaker
and microphone 30 cms
Staff side
Customer side
Typical SecuriCom set up using flush mounted components on the Customer’s side
and combined Staff Unit for Staff.
CUSTOM STAF
POWE
contacta
STS-A 20/30
STS-F70
Staff Unit
10

Siting and Installing the Staff Unit
Amplifier Connections
Connecting Components
to the Amplifier
Controls
The STS-F70 Staff Unit is a self standing module for the Staff Side. It should be placed conveniently on
the counter top so the cashier can hear the loudspeaker and talk into the gooseneck microphone to
the customer. The microphone is of the close talking type so background noise is not picked up. A
‘Mute’ switch is located on the front of the Staff Unit. In the absence of a cable port, a suitably sized
hole should be drilled into the counter top at the rear of the Staff Unit to take the reinforced cable.
Disconnect the 2 two-way plugs before introducing the cables for a neater installation. Ensure these
are re-connected correctly or the system will not operate.
1 LED/Tone (+) 8 Staff Mic 2 (screen) 15 Staff Speaker 2 (+)
2 LED/Tone (-) 9 Customer Mic 2 (+) 16 Staff Speaker 2 (-)
3 Staff Unit Mic 1 (+) 10 Customer Mic 2 (screen) 17 Customer Speaker 2 (+)
4 Staff Unit Mic 1 (screen) 11 Staff Unit Speaker (+) 18 Customer Speaker 2 (-)
5 Customer Mic 1 (+) 12 Staff Unit Speaker (-) 19 Induction Loop Aerial (+)
6 Customer Mic 1
(screen)
13 Customer Speaker 1 (+) 20 Induction Loop Aerial (-)
7 Staff Mic 2 (+) 14 Customer Speaker 1 (-)
Each component (Microphone, Loudspeaker, Staff Unit or Induction Loop) comes fitted with two-way
connection plug(s) which locate into the appropriate socket(s) at the rear of the Amplifier. The plugs
connect to the cables by screw terminal connections so cables can be removed and fed through small,
neatapertures foranunobtrusive, discreteinstallation. However, thecablesand plugsmust bere-con-
nected correctly or the system will not operate. If in
doubt,mark the wiresbefore disconnectingthe plug(s). If
there is a suitable cable port on the cashiers side, the
Staff Unit cables can be diverted through this without the
need to remove and re-connect the 2 two-way plugs.
Controls are provided on the front of the Amplifier. The
latching push switch marked ‘power’ switches the unit
on or off, a red LED indicates when the unit is on. Two
rotary volume controls marked ‘customer’ and ‘staff’
adjust output from the loudspeakers. The volume of the
system may be adjusted by turning the rotary volume
controls clockwise (to increase the level of sound) or
anticlockwise (to decrease the level of sound).
SECURICOM SPEECH TRANSFER SYSTEM INSTALLATION
Contacta Communication Systems Limited
Tel: 0181 858 2123
Power in
Connection
to Induction
Loop Aerial
Induction Cust Staff Cust Staff Cust Staff Cust Staff
Loop Spk 2 Spk 2 Spk 1 Spk 1 Mic 2 Mic 2 Mic 1 Mic 1 LED Tone
-+ -+-+ -+- + Sc+Sc+ Sc+Sc+- +
20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
Connection
plugs
+
-+
-+
-+
-+
-+++
Sc ++
-
Connection
to LED or
tone signal
(optional)
Optional
connections
to second
microphones
Connect
to
customer
loud
speaker
Optional
connections to
second
loudspeakers
Rear of Amplifier showing two-way connections for components
Sc
Sc Sc
Connect
to Staff
Unit
Connect
to
customer
micro-
phone
Connect
to Staff
Unit
Enlarged drawing of two-way plug that connects
components to the rear of the amplifier
Positive +
Negative -
or
Screened
Cable
11